Erratum for Organic acid concentration thresholds for ageing of carbonate minerals: Implications for CO2 trapping/storage.
Low conversion copolymerization of acrylamide AM (monomer-1) have been conducted with acrylic acid AA in dry benzene at 70°C , using Benzoyl peroxide BPO as initiator . The copolymer composition has been determined by elemental analysis. The monomer reactivity ratios have been calculated by the Kelen-Tudos and Finman-Ross graphical procedures. The derived reactivity ratios (r1, r2) are: (0.620, 0.996) for (AM / AA) systems , and found that the reactivity of the monomer AA is more than the monomer AM in the copolymerization of (AA/AM) system. The reactivity ratios values were used for microstructures calculation.
Background: Hypertension from smoking is a chronic medical condition that impacts human health. It has been proved that it could be a significant risk factor for different disorders like brain damage, the lung disease and has been related to the growth of oral diseases. However, there are few and conflicting research on its effect on salivary electrolytes concentrations.
Aim of the study: To assess the effect of hypertension with and without smoking on electrolyte concentrations in saliva and to identify its effect on normal oral balance.
Methods: A total number of 90 subjects included, which is comprised of (49) (54.4 %) males subjects and (41) (45.6 %) females subjects in
... Show MoreIn the present work, radon gas concentrations in different surface soil samples in Baghdad governorate were measured using RAD-7 detector. The results have been shown that, the Radon gas concentrations ranged between (41.67±1.78Bq/m3), to (185.67±4.22Bq/m3), a map showing the distribution of the concentration of radon in selected areas was defined to identify areas with high pollution level. The reason for the high concentration of radon is that these surface soil samples are taken from agricultural areas. It is also known that fertilizers contain uranium levels as well as areas bombed in wars in the country. It is worth noting that all radon concentrations in Baghdad governorate are below the recommended minimum of 200-300Bq/m3) (Inte
... Show MoreDoppler broadening of the 511 keV positron annihilation ??? ? was used to estimate the concentration of defects ?? different deformation levels of pure alnminum samples. These samples were compressed at room temperature to 15, 22, 28, 38,40, and 75 % thickness reduction. The two-state ^sitron-trapping model has been employed. 'I he s and w lineshape parameters were measured using high-resolution gamma spectrometer with high pure germanium detector of 2.1 keV resolution at 1.33 MeV of 60Co. The change of defects concentration (Co) with the deformation level (e) is found to obey an empirical formula of the form Cd - A £ B where A and ? are positive constants that depend mainly on the deformation procedure and the temperature at which the def
... Show MorePolymer electrolytes systems compose of (PEO+KI+I2) and (PEO+RbI+I2) with different concentration, and a fixed amount of ethylene carbonate (EC) and propylene carbonate (PC) over temperatures range 293-343 K prepared by solution cast me
... Show MoreBackground: High serum molybdenum level may contribute to dialysis related bone disease in patients requiring long term hemodialysis in fact massive molybdenum accumulation causes joint deformity and arthritis
Objective: To asses the level of molybdenum in uremic patients requiring long term hemodialysis and impact of hemodialysis on the serum level of molybdenum before and after hemodialysis
Patients and methods: Eighty patients complain from chronic renal failure on long term hemodialysis aged (16 to 65) years, serum molybdenum was measured before and after hemodialysis
Result: The mean serum molybdenum level in 80 patients requiring long term hemodialysis was elevated before dialysis (0.29 + 0.17 nmol/mL) and even after dialy
In this study , extraction of irradiated high concentration hexavallent uranium from fission products ( high gamma radiation ) was carried out using multistages countercurrent continuous technique (mixer setller) , employing this technique requires a designing flow sheet that recover all the amounts of uranium and to minimize its losses in the nuclear waste streams. Due to the several parameters required to reach this design, SEPHIS program which is one of the famous code in this field were used to select the optimum conditions through many theoretical runs , finally the experimental results give a good assurance in SEPHIS results and its optimum conditions.
A hybrid cadmium sulfide nanoparticles (CdSNPs) electroluminescence (EL) device was fabricated by Phase – Segregated Method and characterized. It was fabricated as layers of (ITO/poly-TPD:CdS ) and (ITO/poly-TPD:CdS /Alq3). Poly-TPD is an excellent Hole Transport Layer (HTL), CdSNPs is an emitting layer and Alq3 as electron transport layer (ETL). The EL of Organic-Inorganic Light Emitting Diode (OILED) was studied at room temperature at 26V. This was achieved according to band-to-band transition in CdSNPs. From the I-V curve behavior, the addition of Alq3 layer decreased the transfer of electrons by about 250 times. The I-V behavior for (poly-TPD/CdS) is exponential with a maximum current of 4500 µA. While, the current i
... Show MoreA hybrid cadmium sulfide nanoparticles (CdSNPs) electroluminescence (EL) device was fabricated by Phase – Segregated Method and characterized. It was fabricated as layers of (ITO/poly-TPD:CdS ) and (ITO/poly-TPD:CdS /Alq3). Poly-TPD is an excellent Hole Transport Layer (HTL), CdSNPs is an emitting layer and Alq3 as electron transport layer (ETL). The EL of Organic-Inorganic Light Emitting Diode (OILED) was studied at room temperature at 26V. This was achieved according to band-to-band transition in CdSNPs. From the I-V curve behavior, the addition of Alq3 layer decreased the transfer of electrons by about 250 times. The I-V behavior for (poly-TPD/CdS) is exponential with a maximum current of 45
... Show More