Background: The bond strength of the root canal sealers to dentin is very important property for maintaining the integrity and the seal of root canal filling. The aim of this study was to evaluate and compare the push-out bond strength of root filled with total fill Bioceramic, AH Plus and Gutta-flow®2 sealers using GuttaFusion®obturation system versus single cone obturation technique. Materials and method: sixty of mandibular premolars teeth with straight roots were used in this study, these roots were instrumented using Reciproc system, instrumentation were done with copious irrigation of 3 mL 5.25% sodium hypochlorite solution (NaOCl) during all the steps of preparation, and smear layer will be removed with 1 ml of 17% EDTA kept in the canal for 1 min, roots were randomly divided into two groups according to the obturation technique (thirty teeth for each group): Group I: Single Reciproc Gutta percha cone obturation technique, Group II: Gutta fusion obturation technique, then each group divided into three subgroup according to the type of sealer, AH subgroup: AH Plus sealer, BC subgroup: bioceramic sealer and GF subgroup: Gutta flow 2 sealer. The roots then stored in moist environment at 37°C for one week, the roots were embedded in clear acrylic resin and each root sectioned into three levels apical, middle and cervical. The bond strength was measured using computerized universal testing machine each section fixed in the machine so that the load applied from apical to cervical direction at 0.5mm/min. speed and the computer show the higher bond force before dislodgment of the filling material. These forces were divided by the surface area to obtain the bond strength in MPa. Results: Statistical analysis was performed and the result showed a highly significant differences between the three types of sealers when the same obturation technique were used, also there is highly significant differences between two groups with two different obturation technique. Conclusion: This study showed that the push out bond strength of AH plus sealer was higher than bioceramic sealer and Gutta flow 2 sealer respectively when the same obturation technique was used. The push out bond strength was affected by the obturation technique and Gutta fusion obturation technique showed higher bond strength than single cone obturation technique when the same type of sealer was used.
Background: Imprelon® Biostar foils are new alternative tray material that has become increasingly popular because oftheir several advantages. Also, (Duran®) is another type of Biostar foils which is used in splint therapy. This study assessed some mechanical properties of these two types Biostar sheets in comparison with some types of acrylic resins used for construction of trays and splints. Materials and Methods: A total of 150 specimens were prepared, 30 specimens for each test, 10 for each group material in order to assess some mechanical properties of the Imprelon® Biostar foil (dimension stability, surface roughness and shear bond strength of Imprelon® materialto zinc oxide impression material) and compare them to that of the oth
... Show MoreMelatonin is a potent scavenger of reactive oxygen species or free radicals like superoxide and hydroxyl radicals. The oxidation of hemoglobin to methemoglobin (meth-Hb) by oxidizing compounds has been widely studied. The present work was designed to evaluate the ability of different concentrations of melatonin to inhibit nitrite–induced oxidation of hemoglobin. Blood samples were obtained from apparently healthy individuals from which erythrocyte hemolysate was prepared. Different concentrations of melatonin (10-9-1.0 mg/ml) were incubated for 10 min with the hemolysate, then to the resultant mixture 1 ml of sodium nitrite (final concentration 0.6 mM) was added, and the
... Show MoreSchiff base derived from PVA and Erythroascorbic acid derivative (pentulosono-ɣ-lactone-2, 3-enedianisoate) was synthesized and characterized by Thin Layer Chromatography (TLC) and FTIR spectra, aldehyde was also characterized by (U.V-Vis), 1HNMR, 13CNMR and mass spectra. The inhibitory effect of prepared polymer on the activity of human serum Cholinesrerase has been studied in vitro. The polymer showed a remarkable activity at low concentration (4.5*10-3 – 4.5*10-8 M).
PMMA (Poly methyl methacrylate) is considered one of the most commonly used materials in denture base fabrication due to its ideal properties. Although, a major problem with this resin is the frequent fractures due to heavy chewing forces which lead to early crack and fracture in clinical use. The addition of nanoparticles as filler performed in this study to enhance its selected mechanical properties. The Nano-additive effect investigated in normal circumstances and under a different temperature during water exposure. First, tests applied on the prepared samples at room temperature and then after exposure to water bath at (20, 40, 60) C° respectively. SEM, PSD, EDX were utilized for samples evaluation in this study. Flexural
... Show MoreThe monogeneans Gyrodactylus dzhalilovi Ergens & Ashurova, 1984, G. magnus Konovalov, 1967 and G. matovi Ergens & Kakachava-Avramova, 1966 were recorded in this study for the first time in Iraq from gills of the common carp Cyprinus carpio Linnaeus, 1758 collected from Tigris River in Baghdad city. The description, measurements and illustrations of these parasites were given.
Objectives: This study aims to assess and compare the micro-shear bond strength (μSBS) of a novel resin-modified glass-ionomer luting cement functionalized with a methacrylate co-monomer containing a phosphoric acid group, 30 wt% 2-(methacryloxy) ethyl phosphate (2-MEP), with different substrates (dentin, enamel, zirconia, and base metal alloy). This assessment is conducted in comparison with conventional resin-modified glass ionomer cement and self-adhesive resin cement. Materials and methods: In this in vitro study, ninety-six specimens were prepared and categorized into four groups: enamel (A), dentin (B), zirconia (C), and base metal alloys (D). Enamel (E) and dentin (D) specimens were obtained from 30 human maxillary first premolars e
... Show MoreThe present paper aims at finding out the Variance Ratio of Trips Set Out by Scholars of Both Marrouzzeen and Baihaq .The researcher has come up with conclusion including certain findings ,one of which is that the trip is considered an essential base with high effectiveness since the old times and has been evolved .This means that the trip has been the main source of knowledge and sciences from the scholars directly .This had driven the scholars of both Baihaq and Marrouz cities .It has been noticed , though this paper, that the number of the Marrouz scholars who visited was less than those of Baihaq . The researcher has focused on their meetings or conferences and investigated what has been going on in such meetin
... Show MoreThe present paper aims at finding out the Variance Ratio of Trips Set Out by Scholars of Both Marrouzzeen and Baihaq .The researcher has come up with conclusion including certain findings ,one of which is that the trip is considered an essential base with high effectiveness since the old times and has been evolved .This means that the trip has been the main source of knowledge and sciences from the scholars directly .This had driven the scholars of both Baihaq and Marrouz cities .It has been noticed , though this paper, that the number of the Marrouz scholars who visited was less than those of Baihaq . The researcher has focused on their meetings or conferences and investigated what has been going on in suc
... Show MoreBackground: acrylic resin denture base consider a common denture base material for its acceptable cost, aesthetic and easy processing but still has disadvantages including easy of fracture and low impact strength. Material and method: The experimental group was prepared by addition of 15% phosphoric acid 2-hydroxyethyl methacrylate ester (PA2HEME) with polymethyl methacrylate monomer; the experimental groups was compared with the control one. The specimens were prepared according to ADA specification No. 12 with dimension 65 mm x 10 mm x2.5 mm (length x width x thickness respectively). The prepared specimens were tested by three-point flexural strength utilizing Instron Universal Testing Machine (WDW, Layree Technology Co.), Shore D hard
... Show More