Preferred Language
Articles
/
FRYMYocBVTCNdQwC3klL
In Vitro Comparative Assessment of the Effect of Gutta-Fusion Obturation on the Push Out Bond Strength of Three Types of Sealers
...Show More Authors

Background: The bond strength of the root canal sealers to dentin is very important property for maintaining the integrity and the seal of root canal filling. The aim of this study was to evaluate and compare the push-out bond strength of root filled with total fill Bioceramic, AH Plus and Gutta-flow®2 sealers using GuttaFusion®obturation system versus single cone obturation technique. Materials and method: sixty of mandibular premolars teeth with straight roots were used in this study, these roots were instrumented using Reciproc system, instrumentation were done with copious irrigation of 3 mL 5.25% sodium hypochlorite solution (NaOCl) during all the steps of preparation, and smear layer will be removed with 1 ml of 17% EDTA kept in the canal for 1 min, roots were randomly divided into two groups according to the obturation technique (thirty teeth for each group): Group I: Single Reciproc Gutta percha cone obturation technique, Group II: Gutta fusion obturation technique, then each group divided into three subgroup according to the type of sealer, AH subgroup: AH Plus sealer, BC subgroup: bioceramic sealer and GF subgroup: Gutta flow 2 sealer. The roots then stored in moist environment at 37°C for one week, the roots were embedded in clear acrylic resin and each root sectioned into three levels apical, middle and cervical. The bond strength was measured using computerized universal testing machine each section fixed in the machine so that the load applied from apical to cervical direction at 0.5mm/min. speed and the computer show the higher bond force before dislodgment of the filling material. These forces were divided by the surface area to obtain the bond strength in MPa. Results: Statistical analysis was performed and the result showed a highly significant differences between the three types of sealers when the same obturation technique were used, also there is highly significant differences between two groups with two different obturation technique. Conclusion: This study showed that the push out bond strength of AH plus sealer was higher than bioceramic sealer and Gutta flow 2 sealer respectively when the same obturation technique was used. The push out bond strength was affected by the obturation technique and Gutta fusion obturation technique showed higher bond strength than single cone obturation technique when the same type of sealer was used.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jun 21 2022
Journal Name
Journal Of Planner And Development
Enviromental impact assessment of cement industry using Leopold Matrix
...Show More Authors

The assessment of the environmental impact of the cement industry using the Leopold Matrix is ​​to determine the negative and positive impacts on the environment resulting from this industry, and what are the long-term and short-term effects, direct and indirect, and the amount of these effects and potential risks, and that this evaluation process is done through a number of methods, including Matrix method, including (Leopold).

 

The importance of the research because the cement occupies is of great importance in the world, especially in our country, Iraq, in the sector of construction and modernity, and the toxic emissions and solid waste produced by the production of this material. <

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 04 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of Personal Hygiene for Adults with Diabetic Foot
...Show More Authors

Objective: The aim of the study is to assess the personal hygiene of adult patients with
diabetic foot.
Methodology: A descriptive study was carried out in Baghdad teaching hospital, Al-Karama teaching hospital
and Al-Kindey teaching hospital for the period of 10/1/2006 to 1/9/2006. A purposive "non probability" sample
of (100) patient.
Questionnaire was constructed for achieving the purpose of the study. Data were collected through the
application of the questionnaire and interview technique. Data were analyzed through descriptive statistical
approach (frequency & percentage) and inferential statistical approach (chi-square & correlation) by using of
SPSS.
Results: The study results indicated that the

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 18 2023
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of Personal Hygiene for Adults with Diabetic Foot
...Show More Authors

Objective: The aim of the study is to assess the personal hygiene of adult patients with
diabetic foot.
Methodology: ٨ descriptive study was carried out in Baghdad teaching hospital, Al-Karama teaching hospital
and Al-Kindey teaching hospital for the period of 10/1/2006 to 1/9/2006. A purposive "non probability" sample
of (100) patient.
Questionnaire was constructed for achieving the purpose of the study. Data were collected through the
application of the questionnaire and interview technique. Data were analyzed through descriptive statistical
approach (frequency & percentage) and inferential statistical approach (chi-square ع correlation) by using of
SPSS.
Results: The study results indicated that the ra

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
International Journal Of Chemtech Research
Biological Assessment, Heamatological Study, and Environmental Detection of Eugenol
...Show More Authors

Eugenol is found in essential oils of many plants. It belongs to a class of naturally occurring phenolic monoterpenoids, chemically it is an allyl chain-substituted guaiacol. A study was conducted on the compound of Eugenol, which included different studies. The first study was the determination of eugenol in body fluid, which includes serum, saliva and urine has been found the highest concentration was in urine then serum and saliva. The second study was the hematological study. Complete blood count was accomplished on the volunteers alredy administrated with eugenol contained mouthwash the analysis was accomplished before and after the mouth wash use. The result observed a slightly negative results and was not that significant, wh

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Thu Dec 19 2024
Journal Name
Al-rafidain J Med Sci
Assessment of High Risk Pregnant Women by Fetal Echocardiography
...Show More Authors

Scopus
Publication Date
Thu Mar 04 2021
Journal Name
Journal Of Craniofacial Surgery
Outcome Assessment for Surgical Reconstruction of Mandibular Continuity Defects
...Show More Authors

View Publication
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Nov 01 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Quality of Life Assessment for Patients with Colorectal Cancer
...Show More Authors

Abstract A descriptive study to assess the quality of life (QOL) for patients with colorectal cancer. The study was conducted from Baghdad Teaching Hospital, Al-Yarmouk Teaching Hospital and Radiation Hospital and Nuclear medicine for the period from 1st July/2004 to 1st September/2004. The sample selected by purposive random of (50) patients diagnosed with colorectal cancer and all of them who were under chemotherapy treatment. A questionnaire was prepared for the purpose of the study and comprised of three parts including: 1- Socio-demographical characteristics. 2- Clinical characteristics. 3- and QOL

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 30 2018
Journal Name
Journal Of Engineering
Accuracy Assessment of Stonex X-300 Laser Scanner Cameras
...Show More Authors

Assessment the actual accuracy of laboratory devices prior to first use is very important to know the capabilities of such devices and employ them in multiple domains. As the manual of the device provides information and values in laboratory conditions for the accuracy of these devices, thus the actual evaluation process is necessary.

In this paper, the accuracy of laser scanner (stonex X-300) cameras were evaluated, so that those cameras attached to the device and lead supporting role in it. This is particularly because the device manual did not contain sufficient information about those cameras.

To know the accuracy when using these cameras in close range photogrammetry, laser scanning (stonex X-300) de

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 01 2024
Journal Name
Journal Of Engineering
Assessment of Rutting Resistance for Fiber-Modified Asphalt Mixtures
...Show More Authors

Rutting is one of the most complex and widespread types of distress. The rutting is frequently observed on Iraqi roads, especially at the checkpoints, forming a significant hazard on the asphalt layers. Factors such as heavy loads and high temperatures contribute to this distress. Adding fibers to a hot mix asphalt (HMA) effectively improves performance and extends the lifespan of the flexible pavement. This article used glass, steel, and basalt fibers. The wheel tracking test assessed the fibre-asphalt mixture for rutting resistance and compared it with the mix without adding fibers (control HMA). Meanwhile, the microscopic structure of fibres and asphalt mixture modified with fibers was examined using the Field Emission Scanning E

... Show More
View Publication
Crossref (3)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees21gr
Effect of non-thermal plasma by FE-DBD scheme on lipids in blood in vivo study
...Show More Authors

This study illustrates the impact of non-thermal plasma (Cold Atmospheric Plasma CAP) on the lipids blood, the study in vivo. The lipids are (cholesterol, HDL-Cholesterol, LDL-Cholesterol and triglyceride) are tested. (FE-DBD) scheme of probe diameter 4cm is used for this purpose, and the output voltage ranged from (0-20) kV with variable frequency (0-30) kHz. The effect of non-thermal atmospheric plasma on lipids were studied with different exposure durations (20,30) sec. As a result, the longer plasma exposure duration decreases more lipids in blood.

View Publication
Scopus Crossref