The complexes of the 2-hydroxy-4-Nitro phenyl piperonalidene with metal ions Cr(III), Ni(II), Pt(IV) and Zn(II) were prepared in ethanolic solution. These complexes were characterized by spectroscopic methods, conductivity, metal analyses and magnetic moment measurements. The nature of the complexes formed in ethanolic solution was study following the molar ratio method. From the spectral studies, monomer structures proposed for the nickel (II) and Zinc (II) complexes while dimeric structures for the chromium (III) and platinum (IV) were proposed. Octahedral geometry was suggested for all prepared complexes except zinc (II) has tetrahedral geometry, Structural geometries of these compounds were also suggested in gas phase by using
... Show MoreEquilibrium adsorption isotherm for the removal of trifluralin from aqueous solutions using ? –alumina clay has been studied. The result shows that the isotherms were S3 according Giels classification. The effects of various experimental parameters such as contact time, adsorbent dosage, effect of pH and temperature of trifluralin on the adsorption capacities have been investigated. The adsorption isotherms were obtained by obeying freundlich adsorption isotherm with (R2 = 0.91249-0.8149). The thermodynamic parameters have been calculated by using the adsorption process at five different temperature, the values of ?H, ?G and ?S were (_1.0625) kj. mol-1, (7.628 - 7.831) kj.mol-1 and (_2.7966 - _2.9162) kg.
... Show MoreDrug overdose and poisoning are common clinical problems and could occur with Diphenhydramine hydrochloride (DFH) (one of anti histaminic drug ). It therefore important to study the adsorption of the DFH on pharmaceutical adsorbents which could serve as possible antidotes for the emergency treatment of DFH overdose or poisoning when they occur. The rate and extent of adsorption of DFH on some pharmaceutical adsorbents, bauxite were investigated spectra photometrically also the effect temperature, pH, presence of sucrose as additive have been studied as well, adsorbent's weight and partical size.The equilibrium adsorption contact times were determined for clay surface. Adsorption isotherms have been analyzed by the freundlich model. The appa
... Show MoreWastewater treatment plants operators prefer to make adjustments because they are more cost effective, to use the existing tank instead of building new ones. In this case an imported materials would be used as bio-loads to increase biomass and thus maintain efficiency as the next organic loading increases.In the present study, a local substance "pumice stone" was used as a biological carrier in the aeration tank, and the experiments were carried out in five stages: without biological carriers, filling ratio of 4%,10%,20%, and25% with pumice stone, the maximum organic loading at each stage (1.1884, 1.2144, 1.9432, 2.7768, 3.3141)g BOD /l.d respectively.Other experiments were carried out to determine the best filling ratio, the SS remova
... Show MoreStudies from our laboratory have shown that Δ9-Tetrahydrocannabinol (THC), an ingredient found in marijuana plant Cannabis sativa, can attenuate acute lung injury induced by Staphylococcus enterotoxin B (SEB). In the current study, we investigated the role of THC on the metabolism of SEB-activated lymphocytes. To this end, we determined metabolic potential of SEB-activated lymphocytes treated with vehicle or THC by performing the Cell Mito Stress Test. The oxygen consumption rate (OCR) in THC-treated cells was decreased when compared to vehicle-treated group whereas the extracellular acidification rate (ECAR) was similar in both the groups. Specifically, electron transport chain inhi
Electro coagulation treatment was used for zinc removal from electroplating wastewater of the State Company for Electrical Industries . This wastewater, here consists zinc ions with maximum concentration in solution of 90 ppm .
The parameters that influenced the wastewater treatment are: current density in the range 1-1.4 mA/cm2, pH in the range 5-10, temperature in the range 25-45°C and time in the range 10-180 minute.
The research is a laboratory experimental type using batch system for electrical process with direct current. The cell comprised of aluminum electrode as anode and stainless steel electrode as cathode. Thirty experiments and one hundred fifty sample lab tests were carried out in this research
... Show More