Preferred Language
Articles
/
DhdOu5IBVTCNdQwC7r_x
Turbid of Water By Using Fuzzy C- Means and Hard K- Means
...Show More Authors

In this research two algorithms are applied, the first is Fuzzy C Means (FCM) algorithm and the second is hard K means (HKM) algorithm to know which of them is better than the others these two algorithms are applied on a set of data collected  from the Ministry of Planning on the water turbidity of five areas in Baghdad to know which of these areas are less turbid in clear water to see which months during the year are less turbid in clear water in the specified area.

Scopus Clarivate Crossref
View Publication
Publication Date
Thu Mar 05 2020
Journal Name
Irrigation And Drainage
ECONOMIC ASSESSMENT OF DUYRIDGE DAM AS A WATER‐HARVESTING SCHEME IN IRAQ
...Show More Authors
Abstract<p>Iraq, home of the Tigris and Euphrates rivers, has survived an extreme deficiency of surface water assets over the years. The gap is due to the decline of the Iraqi water share every year, as well as a high demand for water use from different sectors, particularly agriculture.</p><p>Dam development has long given significant economic benefits to Iraq in circulating low‐priced electricity and supporting low‐income farmers by supplying them with a free irrigation system (Zakaria et al, 2012). This encouraged domestic consumption and investment.</p><p>Despite the fact that numerous advantages are expected from dam construction, it should be painstakingly assessed, utilizing cost</p> ... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed May 30 2018
Journal Name
Journal Of Engineering
Numerical Modeling of Water Movement from Buried Vertical Ceramic Pipes through Soils
...Show More Authors

The problem of water scarcity is becoming common in many parts of the world, to overcome part of this problem proper management of water and an efficient irrigation system are needed.  Irrigation with a buried vertical ceramic pipe is known as a very effective in the management of irrigation water.  The two- dimensional transient flow of water from a buried vertical ceramic pipe through homogenous porous media is simulated numerically using the HYDRUS/2D software.  Different values of pipe lengths and hydraulic conductivity were selected.  In addition, different values of initial volumetric soil water content were assumed in this simulation as initial conditions.  Different value

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 04 2015
Journal Name
Environmental Earth Sciences
Isotopic study of water resources in a semi-arid region, western Iraq
...Show More Authors

View Publication
Scopus (36)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Tue May 16 2023
Journal Name
Journal Of Engineering
EXPERIMENTAL INVESTIGATION OF INDIVIDUAL EVACUATED TUBE HEAT PIPE SOLAR WATER HEATING SYSTEMS
...Show More Authors

lar water heating systems with heat pipes of three diameter groups of 16, 22 and 28.5 mm. The first and third groups had evaporator lengths of 1150, 1300 and 1550 mm. The second group had an additional length of 1800 mm. all heat pipes were of fixed condenser length of 200 mm. Ethanol at 50% fill charge ratio of the evaporator volume was used as the heat pipes working fluid. Each heat pipe condenser section was inserted in a storage tank and the evaporator section inserted into an evacuated glass tube of the Owens- Illinois type. The combined heat pipe and evacuated glass tube form an active solar collector of a unique design.
The resulting ten solar water heating systems were tested outdoors under the meteorological conditions of Bag

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Engineering
Performance Evaluation the Turbidity Removal Efficiency of AL-Muthana Water Treatment Plant
...Show More Authors

Turbidity is a visual property of water that expresses the amount of suspended substances in the water. Its presence in quantities more significant than the permissible limit makes the water undrinkable and reduces the effectiveness of disinfectants in treating pathogens. On this basis, turbidity is used as a basic indicator for measuring water quality. This study aims to evaluate the removal efficiency of AL- Muthanna WTP. Water turbidity was used as a basic parameter in the evaluation, using performance improvement evaluation and data from previous years (2016 to 2020). The average raw water turbidity was 26.7 NTU, with a minimum of 14 NTU, with a maximum of 48 NTU. Water turbidity value for 95% of settling daily readi

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Engineering
Performance Evaluation the Turbidity Removal Efficiency of AL-Muthana Water Treatment Plant
...Show More Authors

Turbidity is a visual property of water that expresses the amount of suspended substances in the water. Its presence in quantities more significant than the permissible limit makes the water undrinkable and reduces the effectiveness of disinfectants in treating pathogens. On this basis, turbidity is used as a basic indicator for measuring water quality. This study aims to evaluate the removal efficiency of AL- Muthanna WTP. Water turbidity was used as a basic parameter in the evaluation, using performance improvement evaluation and data from previous years (2016 to 2020). The average raw water turbidity was 26.7 NTU, with a minimum of 14 NTU, with a maximum of 48 NTU. Water turbidity value for 95% of settling daily reading data was

... Show More
Crossref (5)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Ieee Access
Proposition of New Ensemble Data-Intelligence Models for Surface Water Quality Prediction
...Show More Authors

View Publication
Scopus (77)
Crossref (75)
Scopus Clarivate Crossref
Publication Date
Tue Jan 30 2024
Journal Name
Iraqi Journal Of Science
A Study of Drinking Water Properties in Some Hospitals in Baghdad City
...Show More Authors

One of the bigger problems in drinking water is disinfection by-products (DBPs) that come from chlorinated disinfection. This study’s goal was to evaluate the drinking water in Al-Yarmouk Teaching Hospital, Ibn Sina Hospital and Ibn-Al-Nafis Hospital.  Samples were collected between October 2018 and September 2019. Physical and chemical characteristics of the water were studied, including (temperature, hydrogen ion (pH), total dissolved solids (TDS), electrical conductivity (EC), turbidity, free residual chlorine, total organic carbon (TOC), total trihalomethanes (THMs), total halo acetic acid (THAAs)). Data analysis showed the highest value of study temperature, pH, TDS, EC, turbidity, free residual chlorine and TOC which was

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Civil And Environmental Engineering
Investigating the Critical Success Factors for Water Supply Projects: Case of Iraq
...Show More Authors
Abstract<p>Water supply projects (WSP) requires high plan information, specialized capabilities, capable human resources, and high administrative capacity. However, in the developing countries, particularly in Iraq, these projects experience a lack of a large number of these necessities, which shows the need to identify the critical success factors (CSFs). Accordingly, the objectives of this research are to investigate the CSFs for WSP and their significance among the construction (public and private) and education sectors. To achieve this, first we have carried out a comprehensive literature review of the CSFs for WSP. Second, we administrated a questionnaire survey to 260 construction experts </p> ... Show More
View Publication
Scopus (5)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Advances In Public Health
Detection of Antibiotics in Drinking Water Treatment Plants in Baghdad City, Iraq
...Show More Authors

Persistence of antibiotics in the aquatic environment has raised concerns regarding their potential influence on potable water quality and human health. This study analyzes the presence of antibiotics in potable water from two treatment plants in Baghdad City. The collected samples were separated using a solid-phase extraction method with hydrophilic-lipophilic balance (HLB) cartridge before being analyzed. The detected antibiotics in the raw and finished drinking water were analyzed and assessed using high-performance liquid chromatography (HPLC), with fluorometric detector and UV detector. The results confirmed that different antibiotics including fluoroquinolones andB-lactams were detected in the raw an

... Show More
View Publication
Scopus (114)
Crossref (106)
Scopus Crossref