Medical image security is possible using digital watermarking techniques. Important information is included in a host medical image in order to provide integrity, consistency, and authentication in the healthcare information system. This paper introduces a proposed method for embedding invisible watermarking in the 3D medical image. The cover medical image used is DICOM which consists of a number of slices, each one representing a sense, firstly must separate the ROI (Region of Interest) and NROI (Not Region Of Interest) for each slice, the separation process performed by the particular person who selected by hand the ROI. The embedding process is based on a key generated from Arnold's chaotic map used as the position of a pixel in the slices with the highest saturation for embedding a secret message in the NROI because the ROI contains the information of the ill, so it cannot be modified. The evaluation of the proposed method using PSNR and MSE shows good results according to both requirements of the watermark system, the invisibility and quality of the watermarked medical image where the PSNR value is up to 43.3936 and MSE is up to 0.000041.
This study aims to evaluate the performance of the sewage treatment plant in Al-Diwaniya, one of cities in the southern part in Iraq. This evaluation could be used to facilitate effluent quality assessment or optimal process control of the plant. The influent reaching the plant is considered a medium to strong in strength with BOD5/COD ratio in the range 0.23 and 0.69 which can be considered an easily degradable sewage by the biological processes performed by the activated sludge unit. The quality of the effluent was found to be higher than the Iraqi standards for disposal to water bodies. The BOD5/COD ratios of the treated sewage varied over a wide range as low of 0.13 to 1.48 indicating operational problems in the plant. Regression ana
... Show MoreIn this paper, we propose an approach to estimate the induced potential, which is generated by swift heavy ions traversing a ZnO thin film, via an energy loss function (ELF). This induced potential is related to the projectile charge density, ρq(k) and is described by the extended Drude dielectric function. At zero momentum transfer, the resulting ELF exhibits good agreement with the previously reported results. The ELF, obtained by the extended Drude model, displays a realistic behavior over the Bethe ridge. It is observed that the induced potential relies on the heavy ion velocity and charge state q. Further, the numerical results show that the induced potential for neutral H, as projectile, dominates when the heavy ion velocity is less
... Show MoreThe present study aimed to investigated Giardia duodenalis in cattle in some different areas of Wasit province by using molecular study and verification of the genotype of Giardia duodenalis. Collected one hundred fecal samples from cattle, the result showed that the rate of infection was 83% (100) . DNA was extracted from the 100 positive samples from the cattle then amplified using the special tris-phosphatesomerase gene for genotyping A and B. The result of type A infection was (69%) and (45%) of the genotype B. The purpose of this study was to investigate the genotypes of cattle in Wasit province and compare them with previous sources at the NCBI data bank.
This study aims to evaluate the performance of the sewage treatment plant in Al- Diwaniya, one of cities in the southern part in Iraq. This evaluation could be used to facilitate effluent quality assessment or optimal process control of the plant. The influent reaching the plant is considered a medium to strong in strength with BOD5/COD ratio in the range 0.23 and 0.69 which can be considered an easily degradable sewage by the biological processes performed by the activated sludge unit. The quality of the effluent was found to be higher than the Iraqi standards for disposal to water bodies. The BOD5/COD ratios of the treated sewage varied over a wide range as low of 0.13 to 1.48 indicating operational problems in the plant. Regressio
... Show MoreBackground: Chronic myelogenous leukemia is a malignant hematological disease of hematopoietic stem cells. It is difficult to adapt treatment to each patient's risk level because there are currently few clinical tests and no molecular diagnostics that may predict a patient's clock for the advancement of CML at the time of chronic phase diagnosis. Biomarkers that can differentiate people based on the outcome at diagnosis are needed for blast crisis prevention and response improvement. Objective: This study is an effort to exploit the SLC25A3 gene as a potential biomarker for CML. Methods: RT-qPCR was applied to assess the expression levels of the SLC25A3 gene. Results: In comparison to the mean ΔCt of the control group, which was found to b
... Show More
I have written my most important findings in my research are as follows:
The book forty nuclear is one of the writings of the nuclear imam "God's mercy" in which he had collected ahaadeeth from several different sections and diverse, has been described by scientists as the orbit of Islam are all valid conversations.
the duty to pay attention to the Sunnah of the Prophet from the linguistic point of view because it is very rich news and constructional evidence in all sections contained the forty nuclear talks on the news sentences in (30) places divided between the news request, as stated in (13)
home and primary news in (14) home and the news denial in (3) c
... Show MoreA major disadvantage of dose reconstruction by means of thermoluminescence (TL) is the fact that during readout of any TL material exposed to ionizing radiation (i.e., during measuring the glow curve), the radiation-induced signal gets lost. Application of the photo-transferred thermoluminescence phenomenon (PTTL) may offer a solution to this problem. In PTTL, the residual signal that is not destroyed by conventional TL readout (because it comes from deeper electron traps) can be readout through simultaneous stimulation by UV light and heating, allowing to obtain information about the absorbed dose in a second run. The present paper describes the application of PTTL for emergency dose assessment. For