This research is carried out to study the effect of the external post-tensioning technique on the flexural capacity of simply supported composite castellated beam experimentally. In this research, seven composite castellated beams having the same dimensions and material properties were cast and tested up to failure by applied two concentrated loads at 700 mm from each end. Two external strands of 12.7 mm diameter were fixed at each side of the web of strengthening beams and located at depth 180 mm from top fiber of the section (dps) at each end of the beam. The strands have been tensioned by using a hydraulic jack with a constant stress of 100 MPa. This research aims to study the effect of the strengthening by different shapes of strand profiles of external post-tensioning techniques on the flexural capacity of the composite castellated beam. These beams were divided into three groups. Each group contained two composite castellated beams while 7th composite castellated beam kept without strengthening by external post-tensioning technique As control beam. The first group included two beams with straight strand profile of external Post-tensioning. The second group included two beams with a triangular strand profile of external post-tensioning. The third group included two beams with a trapezoidal strand profile of external post-tensioning. All composite castellated beams were simply supported, and all of them were fully shear connections between the concrete slab and steel girder. All beams included the 16 castellated openings and were stiffened by six stiffener plates welded on the web of castellated beams. Three stiffener plates are welded on each side of the web. Two of these stiffener plates welded at the middle of the beam, and four of them welded at locations under the loads. The experimental results of this research were increasing 5.43% in load capacity of an average of the straight profile of composite castellated beams, increasing 18.92% in load capacity of an average of triangular profile composite castellated beams, and increasing 20.71% in load capacity of the trapezoidal profile of composite castellated beams. All the above results were compared with control beams.
In cognitive radio system, the spectrum sensing has a major challenge in needing a sensing method, which has a high detection capability with reduced complexity. In this paper, a low-cost hybrid spectrum sensing method with an optimized detection performance based on energy and cyclostationary detectors is proposed. The method is designed such that at high signal-to-noise ratio SNR values, energy detector is used alone to perform the detection. At low SNR values, cyclostationary detector with reduced complexity may be employed to support the accurate detection. The complexity reduction is done in two ways: through reducing the number of sensing samples used in the autocorrelation process in the time domain and through using the Slid
... Show MoreOxidation of sulfur compounds in fuel followed by an adsorption process were studied using two modes of operation, batch mode and continuous mode (fixed bed). In batch experiment oxidation process of kerosene with sulfur content 2360 ppm was achieved to study the effect of amount of hydrogen peroxide(2.5, 4, 6 and 10) ml at different temperature(40, 60 and 70)°C. Also the effect of amount acetic acid was studied at the optimal conditions of the oxidation step(4ml H2O2 and 60 °C).Besides, the role of acetic acid different temperatures(40, 60, 70) °C and 4ml H2O2, effect of reaction time(5, 30, 60, 120, 300) minutes at temperatures(40,60) °C, 4ml H2O2 and 1 mlHAC)&
... Show MoreBackground: Fractures of patella constitute 1% of all fractures. Various techniques have been described for internal fixation of patella fractures. Superiority of one technique over the other has long been debated. Objective: We reviewed a series of seventy patients with transverse or comminuted fractures of patella treated with cerclage and tension band wiring technique to assess if it had any advantages over k. wires and tension band wiring technique. Type of the study: Retrospective study. Methods; Seventy patients with displaced patella fracture, with a mean age of 47 years (range 13-75) were divided into two groups :group A 36 patients were treated with cerclage and tension bands technique ,and group B 34 patients were fixed by 2 K.
... Show MoreBackground:Fractures of patella constitute 1% of all fractures. Various techniques have been described for internal fixation of patella fractures. Superiority of one technique over the other has long been debated. Objective:We reviewed a series of seventy patients with transverse or comminuted fractures of patella treated with cerclage and tension band wiring technique to assess if it had any advantages over k. wires and tension band wiring technique. Type of the study:Retrospective study.Methods; Seventy patients with displaced patella fracture, with a mean age of 47 years (range 13-75) were divided into two groups :group A 36 patients were treated with cerclageand tensi
... Show MoreThis study was conducted in the poultry fields of the College of Agricultural Engineering Sciences / University of Baghdad from 10/15/2021 to 11/25/2021.To know the effect of adding different levels of Ganoderma lucidum to broiler diets on productive performance. 200 unsexed (Ross 308) chicks of one day age with a starting weight of (40) g were used. The chicks were randomly distributed into four treatments and 50 birds. One treatment included five replicates (10 birds/replicate), and the experimental treatments was as follows: T1, T2, T3, T4, and the percentages of adding reishi mushroom were 0, 0.5, 1, and 1.5 g/kg of feed, respectively, and the birds were fed on three starter diets, growth and final diets, The results of this stu
... Show MoreABSTRACT Background: Cortical bone thickness is important for the stability of mini implants. Placing mini implants in sites of favorable cortical bone thickness would guarantee better initial stability and long-term success. The aim of this study was to investigate gender, side and jaw differences of the buccal cortical bone thickness as a guide for orthodontic mini screw placement. Materials and Methods: The sample was selected from the patients attending the Specialized Health Center in Al-Sadr City / 3D department. Thirty patients (15 males and 15 females) were selected and cone beam computerized tomographic images were done. Then the buccal cortical bone thickness was measured at thirteen inter radicular sites in the maxilla and mandib
... Show MoreThis research aims to solve a problem in the field of accounting and financial knowledge in the world today, that is, the problem of creative accounting. Especially after the global financial crisis and the collapse of many large companies in the world, people find that they use creative accounting methods to distinguish them from reality, showing the results of their activities and their financial status. This research discusses the concept of creative accounting, the most important methods used in financial statements and its relationship with external auditing, and procedures to limit accounting creativity. This study uses descriptive analysis methods after confirming its theoretical aspects in practice. Using the statistical
... Show MoreBackground: presence of lingual vascular foramina and canals in the interforaminal region may increase the risk ofsurgical complications during implant placement or any surgical procedure in this area. Aim of this study is the radiological evaluation of the anatomic characteristic of the lingual foramina and their vascular canals in the anterior of the mandible using cone beam computed tomography. Materials and Methods: Prospective study including 72 Iraqi subjects (31 male and 41 female) ranging from 20 to 59 years, all subjects attended Al-Sharaa dental clinic in AL-Najaf AL-Ashraf city, scanned with CBCT from September 2016 to February 2017. Using 3dimentional and sagittal cross section to detect lingual foramina and their vascular canal
... Show MoreBackground: presence of lingual vascular foramina and canals in the interforaminal regionmay increase the risk ofsurgical complications during implant placement or any surgical procedure in this area.Aim of this study is the radiological evaluation of the anatomic characteristic of the lingual foramina and their vascular canals in the anterior of the mandible using cone beam computed tomography. Materials and Methods: Prospective study including 72 Iraqi subjects (31 male and 41 female) ranging from 20 to 59 years, all subjects attended AL- Sharaa dental clinic in AL-Najaf AL-Ashraf city, scanned with CBCT from September 2016 to February 2017. Using 3dimentional and sagittal cross section to detect lingual foramina and their vascular canals
... Show More