Preferred Language
Articles
/
CxaBCYsBVTCNdQwC2scy
Heterogeneous catalytic degradation of dye by Fenton-like oxidation over a continuous system based on Box–Behnken design and traditional batch experiments
...Show More Authors

In this study, iron was coupled with copper to form a bimetallic compound through a biosynthetic method, which was then used as a catalyst in the Fenton-like processes for removing direct Blue 15 dye (DB15) from aqueous solution. Characterization techniques were applied on the resultant nanoparticles such as SEM, BET, EDAX, FT-IR, XRD, and zeta potential. Specifically, the rounded and shaped as spherical nanoparticles were found for green synthesized iron/copper nanoparticles (G-Fe/Cu NPs) with the size ranging from 32-59 nm, and the surface area was 4.452 m2/g. The effect of different experimental factors was studied in both batch and continuous experiments. These factors were H2O2 concentration, G-Fe/CuNPs amount, pH, initial DB15 concentration, and temperature in the batch system. The batch results showed 98% of 100 mg/L of DB15 was degraded with optimum H2O2 concentration, G-Fe/Cu-NPs dose, pH, and temperature 3.52 mmol/L, 0.7 g/L, 3, and 50℃ respectively. For the continuous mode, the influences of initial DB15 concentration, feed flow rate, G-Fe/Cu-NPs depth were investigated using an optimized experimental Box-Behnken design, while the conditions of pH and H2O2 concentration were based on the best value found in the batch experiments. The model optimization was set the parameters at 2.134 ml/min flow rate, 26.16 mg/L initial dye concentration, and 1.42 cm catalyst depth. All the parameters of the breakthrough curve were also studied in this study including break time, saturation time, length of mass transfer zone, the volume of bed, and volume effluent.

Scopus Crossref
View Publication
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Lab on-a-chip-based, an integrated microfluidic device lo-cost, rapid, and sensitive analysis of Augmentin
...Show More Authors

Microfluidic devices provide distinct benefits for developing effective drug assays and screening. The microfluidic platforms may provide a faster and less expensive alternative. Fluids are contained in devices with considerable micrometer-scale dimensions. Owing to this tight restriction, drug assay quantities are minute (milliliters to femtoliters). In this research, a microfluidic chip consisting of micro-channels carved on substrate materials built using an Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters influence the chip’s width, depth, and roughness. To have a regular channel surface, and low roughness, the laser power (60 W), with scanning speed (250 m/s)

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Mon Dec 01 2014
Journal Name
2014 Ieee Symposium On Differential Evolution (sde)
Comparative analysis of a modified differential evolution algorithm based on bacterial mutation scheme
...Show More Authors

A new modified differential evolution algorithm DE-BEA, is proposed to improve the reliability of the standard DE/current-to-rand/1/bin by implementing a new mutation scheme inspired by the bacterial evolutionary algorithm (BEA). The crossover and the selection schemes of the DE method are also modified to fit the new DE-BEA mechanism. The new scheme diversifies the population by applying to all the individuals a segment based scheme that generates multiple copies (clones) from each individual one-by-one and applies the BEA segment-wise mechanism. These new steps are embedded in the DE/current-to-rand/bin scheme. The performance of the new algorithm has been compared with several DE variants over eighteen benchmark functions including sever

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Civil Engineering Journal
Calibration of a New Concrete Damage Plasticity Theoretical Model Based on Experimental Parameters
...Show More Authors

The introduction of concrete damage plasticity material models has significantly improved the accuracy with which the concrete structural elements can be predicted in terms of their structural response. Research into this method's accuracy in analyzing complex concrete forms has been limited. A damage model combined with a plasticity model, based on continuum damage mechanics, is recommended for effectively predicting and simulating concrete behaviour. The damage parameters, such as compressive and tensile damages, can be defined to simulate concrete behavior in a damaged-plasticity model accurately. This research aims to propose an analytical model for assessing concrete compressive damage based on stiffness deterioration. The prop

... Show More
Scopus (31)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Sun Dec 15 2019
Journal Name
Al-academy
The Effect of The Illustration Program on Fashion Design Inspired by Historical Costumes: تهاني ناصر العجاجي -هدى عبد العزيز المقرن
...Show More Authors

This research aims to identify the role and impact of illustrations in contemporary fashion design inspired by historical costumes. Historical fashion aesthetics are adapted to design drawings. The experimental method was followed and a sample of 31 students in the department of fashion and textile design, third level were selected. Each student carried out two original historical and contemporary design. The models were executed two times: one with the usage of the program and the other without program help. The tools that were used are the program, the scale, the pre-skill test, and the post-skill test. One of the most relevant results of the research is the possibility of using historical costumes to highlight creativity and innovatio

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2024
Journal Name
Baghdad Science Journal
Some Results about Acts over Monoid and Bounded Linear Operators
...Show More Authors

 الأثر V بالنسبة إلى   sinshT و خواصه قد تم دراسته في هذا البحث حيث تم دراسة علاقة الأثر المخلص والاثر المنتهى التولد والاثر المنفصل وربطها بالمؤثرات المتباينة حيث تم بهنة العلاقات التالية ان الاثر اذا وفقط اذا مقاس في حالة كون المؤثر هو عديم القوة وكذلك في حالة كون المؤثر شامل فان الاثر هو منتهي التولد اي ان الغضاء هو منتهي التولد وايضا تم برهن ان الاثر مخلص لكل مؤثر مقيد وك\لك قد تم التحقق من انه لاي مؤثر مقي

... Show More
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Tue Feb 20 2024
Journal Name
Baghdad Science Journal
Some Results about Acts over Monoid and Bounded Linear Operators
...Show More Authors

This study delves into the properties of the associated act V over the monoid S of sinshT. It examines the relationship between faithful, finitely generated, and separated acts, as well as their connections to one-to-one and onto operators. Additionally, the correlation between acts over a monoid and modules over a ring is explored. Specifically, it is established that  functions as an act over S if and only if  functions as module, where T represents a nilpotent operator. Furthermore, it is proved that when T is onto operator and  is finitely generated, is guaranteed to be finite-dimensional. Prove that for any bounded operator the following,  is acting over S if and only if  is a module where T is a nilpotent operator, is a

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Energy Procedia
Design and Construction of Nanostructure TiO2 Thin Film Gas Sensor Prepared by R.F Magnetron Sputtering Technique
...Show More Authors

In this research, Mn-doped TiO2 thin films were grown on glass, Si and OIT/glass substrates by R.F magnetron sputtering technique with thicknesses (250 nm) using TiO2:Mn target under Ar gas pressure and power of 100 Watt. Through the results of X-ray diffraction, the prepared thin films are of the polycrystallization type after the process of annealing at 600°C for two hour The average crystalline size were 145.32, 280.97 and 261.23 nm for (TiO2:Mn) thin film on glass, Si and OIT/glass substrates respectively, while the measured surface roughness is between 0.981nm and 1.14 nm. The fabricated (TiO2:Mn) thin film on glass sensors have high sensitivity for hydrogen( H2 reducing gas) compared to the sensitivity for hydrogen gas on Si and OIT/

... Show More
View Publication
Crossref (27)
Crossref
Publication Date
Sun Jun 20 2021
Journal Name
Baghdad Science Journal
Projective MDS Codes Over GF(27)‎
...Show More Authors

MDS code is a linear code that achieves equality in the Singleton bound, and projective MDS (PG-MDS) is MDS code with independents property of any two columns of its generator matrix.   In this paper, elementary methods for modifying a PG-MDS code of dimensions 2, 3, as extending and lengthening, in order to find new incomplete PG-MDS codes have been used over . Also, two complete PG-MDS codes over  of length  and 28 have been found.

View Publication Preview PDF
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Dec 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Regeneration of SLFO_Nitro Acid Mixture in Continuous Mode Operation
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Jan 30 2026
Journal Name
Kerbala Journal Of Pharmaceutical Sciences
Determination of Methionine Via Chemiluminescence-Continuous Flow Injection Analysis
...Show More Authors

The research work represent a fast and simple method for the determination of methionine using chemiluminescence for the methionine-sodium hydroxide-luminol for the generation of a chemiluminesecent derivative of luminal. The emission was measured by continuous flow analysis made sample size of 83µL was used.Response versus concentration extended from 0.2-20 mM.L-1 with a percentage linearity of 96.17% or with 99.17% percentage of linearity for the range 0.6-20 mM.L-1. Reaching to a L.O.D. at (S/N=3) for 5 µM.L-1 from the gradual dilution for the minimum concentration in the calibration graph with a repeatability of less than 0.5% (n=10). A comparison was made between the new developed method with the classical method for the spectrophoto

... Show More
View Publication