BACKGROUND: Volar Barton’s fracture is a shearing mechanism of injury that results in fracture and subluxation of distal end radius in which volar rim of the distal radius is displaced with hand and carpus. Open reduction and volar plate fixation ensure more stable change of displacement, preservation of reduction, and early mobilization. AIM: This study aims to assess the functional and radiological outcome results of volar Barton’s fracture treated by volar buttress plate using the demerit points system of Gartland and Werley. PATIENTS AND METHODS: This study is a prospective descriptive observational study on 32 patients who were treated with ORIF by volar buttress plate for isolated volar Barton’s fractures between February 2018 and June 2020 in Alkindy teaching hospital/Baghdad/Iraq. All volar Barton’s fracture cases satisfying the inclusion criteria which included patient over 18 years, isolated fracture, medically fit, and <5 days old injuries, while fractures extend to radius shaft, compound fractures, and associated with other injuries were excluded from the study. All fractures are fixed by volar locked plate followed up for 12 week’s duration for functional and radiological assessment using the Demerit points system of Gartland and Werley. RESULTS: Most cases were in the age group below 40 years, average age 38 years (range 19–64 years), male patient was 69%, side of involvement was right wrist in 75% of cases, falling on an outstretched hand account 50%, while roads traffic accidents in 37.5%, fall from a height in 6.25%, and direct trauma in 6.25%. The final sequel of the results was average volar tilt was 11.1°, the radial shortening average was 4 mm, the radial inclination average was 19.9°, and the ulnar variance was 0.3 mm. Functional outcomes depending on Gartland and Werley’s score were 50% as excellent results, 43.75% as good results, 6.25% as fair results, and no poor results in this study. CONCLUSIONS: Volar locking buttress plate provides fracture stability and early mobilization, therefore, recovery of daily live activity in a short time.
The increased use of hybrid PET /CT scanners combining detailed anatomical information along withfunctional data has benefits for both diagnostic and therapeutic purposes. This presented study is to makecomparison of cross sections to produce 18F , 82Sr and68Ge via different reactions with particle incident energy up to 60 MeV as a part of systematic studies on particle-induced activations on enriched natNe, natRb, natGa 18O,85Rb, and 69Ga targets, theoretical calculation of production yield, calculation of requiredtarget and suggestion of optimum reaction to produce: Fluorine-18 , Strontium-82 andGermanium-68 touse in Hybrid Machines PET/CT Scanners.
Eprospective study undertaken between January 2007 and January 2011, 58 consecutive cases with compound tibial shaft fractures. All fractures were stabilized by external fixator device AO/ASIF type after failed the manipulation under anesthesia (MUA) to restore the osseous alignment. In 32 patients cancellous bone graft were used from the upper part of the tibia to enhance healing process, all these patients were followed for an average of 8–12 months. Our findings showed that stabilization of the fracture shaft tibia by external fixation with cancellous bone graft had significantly better result, than external fixation alone. We conclude that unilateral, uniplanar external fixation with early bone grafting from upper part of the tibia is
... Show MoreWhat has reached us from this great heritage left by our scientists book ((masterpiece of honor by knowing the parties)) to the conservative privilege, which Imam Safadi said ((Sheikh of time, and the preservation of the era, and critic of the time, if his son Ibn Makola had a drink and eaten, and make it to him So, after trusting in God, I thought that I should write a paper highlighting the life of this great world and explaining its methodology in this useful book in which Imam Ibn Hajar al-Asqalani said: `` The use of it took place east and west, and the scholars competed in collecting it after. And soon)).
Praise be to God, and may blessings and peace be upon our master and Prophet Muhammad and those who follow him, and may God be pleased with him
Taha is my guardian and whoever follows their path until the Day of Judgment. And after... The book (The Treasure in the Ten Recitations), written by Abu Muhammad Abdullah bin Abd al-Wasiti, who died in the year 710 AH, is considered one of the important books in recitations: because it included the universal custom that it contained in the books Al-Taysir by Al-Dani and Al-Irshad by Al-Falanisi, as the first of them was specialized.
Satisfy the second with the ten readings
May God bless my time, through His grace and generosity, to achieve this treasure and to publish it
... Show MoreIn this work, a magnetic switch was prepared using two typesof ferrofluid materials, the pure ferrofluid and ferrofluid doped with copper nanoparticles (10 nm). The critical magnetic field (Hc) and the state of magnetic saturation (Hs) were studied using three types of laser sources. The main parameters of the magnetic switch measured using pure ferrofluid and He-Ne Laser source were Hc(0.5 mv, 0.4 G), Hs (8.5 mv, 3 G). For the ferrofluid doped with copper nanoparticles were Hc (1 mv, 4 G), Hs (15 mv, 9.6 G), Using green semiconductor laser for the Pure ferrofluid were Hc (0.5 mv, 0.3 G) Hs (15 mv, 2.9 G). While the ferrofluid doped with copper nanoparticles were Hc (0.5 mv, 1 G), Hs (12 mv, 2.8 G) and by using the violet semiconductor l
... Show MoreIn this study, the response and behavior of machine foundations resting on dry and saturated sand was investigated experimentally. In order to investigate the response of soil and footing to steady state dynamic loading, a physical model was manufactured. The manufactured physical model could be used to simulate steady state harmonic load at different operating frequencies. Total of (84) physical models were performed. The parameters that were taken into considerations include loading frequency, size of footing and different soil conditions. The footing parameters were related to the size of the rectangular footing and depth of embedment. Two sizes of rectangular steel model footing were used (100 200 12.5 mm) and (200 400 5.0 mm).
... Show MoreThis study was carried out to measure the percentage of heavy metals pollution in the water of the Diyala river and to measure the percentage of contamination of these elements in the leafy vegetables grown on both sides of the Diyala river, which are irrigated by the contaminated river water (celery, radish, lepidium, green onions, beta vulgaris subsp, and malva). Laboratory analysis was achieved to measure the ratio of heavy element contamination (Pb, Fe, Ni, Cd, Zn and Cr) using flame atomic absorption spectrophotometer during the summer months of July and August for the year 2017. The study showed that the elements of zinc, chromium, nickel and cadmium were high concentrations and exceeded. The maximum concentration of these
... Show MoreAlloy of (HgTe) has been prepared succesful in evacuated qurtz ampoule at pressure 4×10-5torr, and melting temperature equal to 823K for five days. Thin films of HgTe of thickness 1μm were deposited on NaCl crystal by thermal evaporation technique at room temperature under vacuum about 4×10-5torr as well as investiagtion in the optical porperties included (absorption coefficient , energy gap) of HgTe films and The optical measurements showed that HgTe film has direct energy gap equal to 0.05 eV. The optical constants (n, k, εr, εi) have been measured over will range (6-28)μm.