Preferred Language
Articles
/
Ahdvh5IBVTCNdQwCBbOX
Estimation intensity radiation of chest X-ray (CXR) with application
...Show More Authors

In this research we assumed that the number of emissions by time (𝑡) of radiation particles is distributed poisson distribution with parameter (𝑡), where  < 0 is the intensity of radiation. We conclude that the time of the first emission is distributed exponentially with parameter 𝜃, while the time of the k-th emission (𝑘 = 2,3,4, … . . ) is gamma distributed with parameters (𝑘, 𝜃), we used a real data to show that the Bayes estimator 𝜃 ∗ for 𝜃 is more efficient than 𝜃̂, the maximum likelihood estimator for 𝜃 by using the derived variances of both estimators as a statistical indicator for efficiency

Scopus
Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Structural and optical properties for nano GaxSb1-x films
...Show More Authors

Alloys of GaxSb1-x system with different Ga concentration (x=0.4, 0.5, 0.6) have been prepared in evacuated quartz tubes. The structure of the alloys were examined by X-ray diffraction analysis (XRD) and found to be polycrystalline of zincblend structure with strong crystalline orientation (220). Thin films of GaxSb1-x system of about 1.0 μm thickness have been deposited by flash evaporation method on glass substrate at 473K substrate temperature (Ts) and under pressure 10-6 mbar. This study concentrated on the effect of Ga concentration (x) on some physical properties of GaxSb1-x thin films such as structural and optical properties. The structure of prepared films for various values of x was polycrystalline. The X-ray diffraction analy

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 31 2024
Journal Name
Indian Journal Of Clinical Biochemistry
Farnesoid X Receptor-Mediated Bile Acids Regulation in Cholestasis
...Show More Authors

The main process, for the elimination of cholesterol from the human body, involves the alteration of cholesterol into bile acid (BA), by the liver. The farnesoid X receptor (FXR), a member of the nuclear receptor superfamily, is essential for the regulation of BA, glucose, and lipid metabolism. It is largely found in the liver, intestines, kidney, and adrenal glands, and to a smaller degree in the heart and adipose tissue. The binding locations, of the FXR, are in close proximity to formerly undisclosed target genes, with distinctive activities associated with transcriptional regulators, autophagy, apoptosis, hypoxia, inflammation, RNA processing, and a number of cellular signaling pathways. The preservation of BA homeostasis, by the FXR, e

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Periodicals Of Engineering And Natural Sciences
Employment of the genetic algorithm in some methods of estimating survival function with application
...Show More Authors

Intended for getting good estimates with more accurate results, we must choose the appropriate method of estimation. Most of the equations in classical methods are linear equations and finding analytical solutions to such equations is very difficult. Some estimators are inefficient because of problems in solving these equations. In this paper, we will estimate the survival function of censored data by using one of the most important artificial intelligence algorithms that is called the genetic algorithm to get optimal estimates for parameters Weibull distribution with two parameters. This leads to optimal estimates of the survival function. The genetic algorithm is employed in the method of moment, the least squares method and the weighted

... Show More
Scopus (2)
Scopus
Publication Date
Thu Jul 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Double-Exponential-X Family of Distributions: Properties and Applications
...Show More Authors

A new family of distribution named Double-Exponential-X family is proposed. The proposed family is generated from the double exponential distribution. The forms of the probability densities and hazard functions of two distinct subfamilies of the proposed family are examined and reported. Generalproperties such as moment, survival, order statistics, probability weighted moments and quartile functions of the models are investigated. A sub family of the developed family of double –Exponential-X family of the distribution known as double-Exponential-Pareto distribution was used to fit a real life data on the use of antiretroviral drugs. Molecular simulation of efficacy of antiretroviral drugs is conducted to evaluate the performance of the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 30 2018
Journal Name
Journal Of Engineering
Accuracy Assessment of Stonex X-300 Laser Scanner Cameras
...Show More Authors

Assessment the actual accuracy of laboratory devices prior to first use is very important to know the capabilities of such devices and employ them in multiple domains. As the manual of the device provides information and values in laboratory conditions for the accuracy of these devices, thus the actual evaluation process is necessary.

In this paper, the accuracy of laser scanner (stonex X-300) cameras were evaluated, so that those cameras attached to the device and lead supporting role in it. This is particularly because the device manual did not contain sufficient information about those cameras.

To know the accuracy when using these cameras in close range photogrammetry, laser scanning (stonex X-300) de

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Gamma Ray Effect on the Properties of Coumarin C47 Laser Dye
...Show More Authors

The research is concerned about studying the absorption spectrum of the solution coumarin dye C47. The chloroform solvent was used with C47 dye in three different concentrations 10-4, 10-5 and 10-6 M. The laser dye solution was prepared by dissolving the required amount of dye in chloroform alcohol, while studying absorption spectrum before and after irradiation with gamma ray by cobalt-60 source 60Co at exposure time, which are 0, 4, 6 and 18 hours with different absorbed doses 0, 136, 204 and 612 Gy. The results show that red shift in the absorption spectrum was increased by increasing the concentration of laser dye solutions , while the increase of gamma dose led to increase the red shift after irradiation, as the exposure period and irr

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Sun Dec 07 2014
Journal Name
Baghdad Science Journal
Estimation of Serum Osteocalcin Levels in Osteoporotic Postmenopausal Iraqi Women with Type 2 Diabetes Mellitus
...Show More Authors

Background: Osteoporosis (OP) is a systemic disease characterized by low bone mass and micro architectural deterioration of bone tissue, resulting in an increased risk of fractures and has touched rampant proportions. Osteocalcin, one of the osteoblast-specific proteins, showed that its functions as a hormone improves glucose metabolism and reduces fat mass ratio. This study is aimed to estimate the osteocalcin and glucose level in blood serum of osteoporotic postmenopausal Women with and without Type 2 Diabetes.Materials and methods: 60 postmenopausal women with osteoporosis divided into two groups depending on with or without T2DM, 30 patients for each. Serum samples of 30 healthy postmenopausal women were collected as control group. Ost

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jul 01 2024
Journal Name
Alexandria Engineering Journal
Comparison of some Bayesian estimation methods for type-I generalized extreme value distribution with simulation
...Show More Authors

The Weibull distribution is considered one of the Type-I Generalized Extreme Value (GEV) distribution, and it plays a crucial role in modeling extreme events in various fields, such as hydrology, finance, and environmental sciences. Bayesian methods play a strong, decisive role in estimating the parameters of the GEV distribution due to their ability to incorporate prior knowledge and handle small sample sizes effectively. In this research, we compare several shrinkage Bayesian estimation methods based on the squared error and the linear exponential loss functions. They were adopted and compared by the Monte Carlo simulation method. The performance of these methods is assessed based on their accuracy and computational efficiency in estimati

... Show More
View Publication
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Relative intensity distribution in the rotational structure for B1Σ+- A1Π and B1Σ+- X1Σ+ electronic systems of BeO molecule
...Show More Authors

Theoretical spectroscopic study of  Beryllium Oxide has been carried out, Boltzmann distribution of P, Q and R branches in the range of (0<J<13) at temperature 4200K for (0-0) band for electronic transitions B1Σ+-A1Π and B1Σ-X1Σ. The Boltzmann distribution of these branches has a maximum values at equal J approximately while the values of relative population are different. For the B1Σ+- X1Σ+ transition the branch's lines extend towards lower wavenumber. This is because (Bv'-Bv") value is negative, i.e  Bv'< Bv" For B1Σ+-A1Π

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Gamma radiation induced changes in the optical properties of CdTe thin films for dosimetric purposes
...Show More Authors

The effect of 0.662MeV gamma radiation on the optical properties of the CdTe thin films was studied. 300nm thickness of CdTe samples were irradiated with doses (10, 20, 30,60krad) in room temperature. The absorption spectra for all the samples were recorded using UV- Visible spectrometer in order to calculate the energy gap, width of localized states and optical constants(refractive index, extinction coefficient, real and imaginary parts of dielectric constant). The optical energy gap was found to decrease from (1.53 to 1.48 eV), while the width of localized states increased from (1.34 to 1.49 eV) with the increasing of radiation dose. The behavior of energy gap with the irradiation dose makes the material a good candidate for dosimetry

... Show More
View Publication Preview PDF