In this research we assumed that the number of emissions by time (𝑡) of radiation particles is distributed poisson distribution with parameter (𝑡), where  < 0 is the intensity of radiation. We conclude that the time of the first emission is distributed exponentially with parameter 𝜃, while the time of the k-th emission (𝑘 = 2,3,4, … . . ) is gamma distributed with parameters (𝑘, 𝜃), we used a real data to show that the Bayes estimator 𝜃 ∗ for 𝜃 is more efficient than 𝜃̂, the maximum likelihood estimator for 𝜃 by using the derived variances of both estimators as a statistical indicator for efficiency
In this research, has been to building a multi objective Stochastic Aggregate Production Planning model for General al Mansour company Data with Stochastic demand under changing of market and uncertainty environment in aim to draw strong production plans. The analysis to derive insights on management issues regular and extra labour costs and the costs of maintaining inventories and good policy choice under the influence medium and optimistic adoption of the model of random has adoption form and had adopted two objective functions total cost function (the core) and income and function for a random template priority compared with fixed forms with objective function and the results showed that the model of two phases wit
... Show MoreAbstract :
The study aims at building a mathematical model for the aggregate production planning for Baghdad soft drinks company. The study is based on a set of aggregate planning strategies (Control of working hours, storage level control strategy) for the purpose of exploiting the resources and productive capacities available in an optimal manner and minimizing production costs by using (Matlab) program. The most important finding of the research is the importance of exploiting during the available time of production capacity. In the months when the demand is less than the production capacity available for investment. In the subsequent months when the demand exceeds the available energy and to minimize the use of overti
... Show MoreCollagen triple helix repeat containing-1 (CTHRC1) is an essential marker for Rheumatoid Arthritis (RA), but its relationship with pro-inflammatory, anti-inflammatory, and inflammatory markers has been scantily covered in extant literature. To evaluate the level of CTHRC1 protein in the sera of 100 RA patients and 25 control and compare levels of tumour necrosis factor alpha (TNF-α), interleukin 10 (IL-10), RA disease activity (DAS28), and inflammatory factors. Higher significant serum levels of CTHRC1 (29.367 ng/ml), TNF-α (63.488 pg/ml), and IL-10 (67.1 pg/ml) were found in patient sera as compared to that in control sera (CTHRC1 = 15.732 ng/ml, TNF-α = 33.788 pg/ml, and IL-10 = 25.122 pg/ml). There was no significant correlation be
... Show MoreCollagen triple helix repeat containing-1 (CTHRC1) is an essential marker for Rheumatoid Arthritis (RA), but its relationship with pro-inflammatory, anti-inflammatory, and inflammatory markers has been scantily covered in extant literature. To evaluate the level of CTHRC1 protein in the sera of 100 RA patients and 25 control and compare levels of tumour necrosis factor alpha (TNF-α), interleukin 10 (IL-10), RA disease activity (DAS28), and inflammatory factors. Higher significant serum levels of CTHRC1 (29.367 ng/ml), TNF-α (63.488 pg/ml), and IL-10 (67.1 pg/ml) were found in patient sera as compared to that in control sera (CTHRC1 = 15.732 ng/ml, TNF-α = 33.788 pg/ml, and IL-10 = 25.122 pg/ml). There was no significant correlati
... Show MoreThis study includes the manufacture of four ternary alloys represented S60Se40-XPbX with weight ratios x = 0, 10, 20, and 30 by the melting point method. The components of each alloy were mixed separately, then placed in quartz ampoules and vacuumed out with a vacuum of roger that 10−4 Torr. The ampule was heated in two stages to avoid sudden dissipation and precipitation of selenium on the inner mass of the quartz tube. The ampoule was gradually heated and kept at 450°C for approximately 4 hours followed by 950°C for 10 hours.at a rate of 10 degrees Celsius, the temperature of the electric furnace
n this work, the effect of gamma rays on blood thinning drugs was studied using the drug (Aspirin), where gamma rays were spread with the drug using a radioactive source (Co60), and 15,000 grams of Aspirin were placed in the device (gamma chamber 900). The drug was subjected to different irradiation doses (5 KGy, 10 KGy, 15 KGy) and the amount of absorption of the drug was observed in the gamma for different doses and the study of x-rays. After confirming the absorption of the drug to radiation, the effect of the drug on blood thinning was calculated using the rat model and compared with the same drug and the same dose but without exposing the drug to radiation and comparing all results with the control group. The way drugs absorbed radiati
... Show MoreActivities associated with mining of uranium have generated significant quantities of waste materials containing uranium and other toxic metals. A qualitative and quantitative study was performed to assess the situation of nuclear pollution resulting from waste of drilling and exploration left on the surface layer of soil surrounding the abandoned uranium mine hole located in the southern of Najaf province in Iraq state. To measure the specific activity, twenty five surface soil samples were collected, prepared and analyzed by using gamma- ray spectrometer based on high counting efficiency NaI(Tl) scintillation detector. The results showed that the specific activities in Bq/kg are 37.31 to 1112.47 with mean of 268.16, 0.28 to 18.57 with
... Show MoreOptical detector was manufactured Bashaddam thermal evaporation technique at room temperature under pressure rays studied characteristics of reactive Scout efficiency quantitative ratio of the signal and the ability equivalent to noise
 
        