Preferred Language
Articles
/
AhbnkYcBVTCNdQwCvFaH
Influence of Light Color on Power Generation and Microalgae Growth in Photosynthetic Microbial Fuel Cell with Chlorella Vulgaris Microalgae as Bio-Cathode
...Show More Authors

Crossref
View Publication
Publication Date
Sun Sep 02 2012
Journal Name
Baghdad Science Journal
Influence of Fluoride Addition on Hydroxyapatite Prepared for Medical Applications
...Show More Authors

In this study, hydroxyapatite (HAP, Ca10(PO4)6(OH)2) has been prepared as bioceramic material with biological specifications useful to used for orthopedic and dental implant applications. Wet chemical processing seems to form the fine grain size and uniform characteristic nanocrystalline materials by the interstice factors controlling which affected the grain size and crystallinity in order to give good mechanical and/or constituent properties similar as natural bone. Fluorinated hydroxyapatite [4-6 wt% F, (FHA, Ca10(PO4)6(OH)2–Fx] was developed in new method for its posses to increased strength and to give higher corrosion resistance in biofluids than pure HAP moreover reduces the risk of dental caries. The phase's and functional groups

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Jan 31 2015
Journal Name
International Journal Of Research In Applied, Natural And Social Sciences
The Influence of Premenopausal Simple Hysterectomy on Bone Mass Density
...Show More Authors

Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Influence of non-thermal argon plasma needle on blood coagulation
...Show More Authors

Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 12 2020
Journal Name
Al-khwarizmi Engineering Journal
The Influence of ProcessVariables for MillingSculptured Surfaces on Surface Roughness
...Show More Authors

Increasing the variety of products that are being designed with sculptured surfaces, efficient machining of these surfaces has become more important in many manufacturing industries. The objective of the present work is the investigation of milling parameters for the sculptured surfacesthat effecting of surface roughness during machining of Al-alloy. The machining operation implemented on C-TEK CNC milling machine. The influence of the selected variables on the chosen characteristics have been accomplished using Taguchi design approach, also ANOVA had been utilized to evaluate the contributionsof each parameter on proc

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 19 2020
Journal Name
Innovations In Pharmacy
Influence of Pharmacy Characteristics and Customer Quality of Life on Satisfaction of Community Pharmacy Customers
...Show More Authors

Objectives: The study objectives were to evaluate customer satisfaction with community pharmacy services and measure the relationships between customer satisfaction and pharmacy/pharmacist characteristics and customer quality of life. Methods: This was a cross-sectional survey of a convenience sample of customers at 20 community pharmacies in 10 different geographical areas in Baghdad city between May and September 2018. We used the satisfaction items which were developed by Paterson and colleagues in 2013. The survey also assessed customer quality of life (QoL) with 12 QoL items. Results: The study recruited 400 pharmacy customers. Overall, customers reported good satisfaction with community pharmacy services. The most

... Show More
View Publication
Crossref (8)
Crossref
Publication Date
Sat Jan 17 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of LED Light on Depth of Cure and Microhardness of Three Types of Bulkfill Composite
...Show More Authors

Background: To evaluate the ISO depth of cure of bulkfill composites and depth of cure which determined by Vickers microhardness test. Materials and Methods: Bulkfill resin composite specimens (n=150) were prepared of three bulkfill composite materials (TetricEvo Ceram, Quixfil and SDR) and light cured by Flash max p3 for 3, 10, 20 seconds and by wood pecker for 10, 20 seconds respectively, a mold was filled with one of the three bulkfill composites and light cured. The specimens removed from the mold and scraped by plastic spatula and the remaining length (absolute length) was measured which represent the ISO depth of cure. After that the specimens were returned into the mold and a microhardness indentation device applied on the specimen

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 11 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Study of Microbial Contamination of Some Commercial Contact Lens Solutions
...Show More Authors

Sixty samples of commercially available contact lens solutions were collected from students at the Pharmacy College/Baghdad University. The types of lenses used varied from medical to cosmetic. They were cultured to diagnose any microbial contamination within the solutions. Both used and unused solutions were subject for culturing. Thirty six (60%) used samples showed bacterial growth, fungal growth was absent. Pseudomonas aeruginosa accounts for the highest number of isolates (25%) followed by E. coli (21%), Staphylococcus epidermidis (6.6%), Pseudomonas fluorescence (5%) and Proteus mirabilis (1.6%) respectively. Only one (1) unused (sealed) sample showed growth of P. fluorescence.

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Dec 01 2002
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
CORRELATIVE INFLUENCE OF SEEDLING AGE, COTYLEDONS AND TERMINAL BUDS ON ADVENTITIOUS ROOT FORMATION IN STEM CUTTINGS OF MUNG BEAN
...Show More Authors

Rooting response in stem cuttings of mung bean increased considerably with inresing
seedling age, due to endogenous IAA or supplied IBA. However, after the day 7- or 8-old of
seedling age. The cotyledons sheivel and drop-off spontaneously at day-8 of seedling age. So
that cotyledons excision after cuttings were made during the period between seedling
emergence (the day 4) and cotyledons dropping off (which starts at day 8 and its completion
at day 10) causes decrease in rooting at any time during cutting treatment ,in particular, at
zero time . In addition, results of this study revealed that terminal buds do not influence
significantly adventitious root formation whether IBA supplied or not. Whereas in leafless
c

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 01 2024
Journal Name
Cytokine
Lupeol stimulates iNOS, TNF-α, and IL-10 expression in the U937 cell line infected with old-world Leishmania donovani
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the accuracy of a fifth generation apex locator (in vitro study)
...Show More Authors

Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for t

... Show More
Preview PDF