Catalytic wet air oxidation of aqueous phenol solution was studied in a pilot plant trickle bed reactor using copperoxide catalyst supported on alumina and silica. Catalysts were prepared by impregnating method. Effect of feed solutionpH (5.9, 7.3, and 9.2), gas flow rate (20%, 50%, 80%, and 100%), WHSV (1, 2, and 3 h-1), temperature (120°C, 140°C,and 160°C), oxygen partial pressure (6, 9, 12 bar), and initial phenol concentration (1, 2, and 4 g/l).Generally, theperformance of the catalysts was better when the pH of feed solution was increased. The catalysts deactivation is relatedto the dissolution of the metal oxides from the catalyst surface due to the acidic conditions. Phenol oxidation reactionwas strongly affected by WHSV, temperature, oxygen partial pressure, and initial phenol concentration. While gas flowrate had a marginal effect.
This paper deals the prediction of the process of random spatial data of two properties, the first is called Primary variables and the second is called secondary variables , the method that were used in the prediction process for this type of data is technique Co-kriging , the method is usually used when the number of primary variables meant to predict for one of its elements is measured in a particular location a few (because of the cost or difficulty of obtaining them) compare with secondary variable which is the number of elements are available and highly correlated with primary variables, as was the&nbs
... Show MoreObjectives: To assess the level of dependence severity, locus of control, and readiness to change in male alcohol clients and measure the correlation between dependence with a locus of control and readiness to change.
Methodology: A descriptive correlational design was conducted in the substance use rehabilitation centers at psychiatric teaching hospitals in Baghdad city from November /2021 to May 2022. The instrument of the study was designed by using sociodemographic, the clinical characteristics of the client, the Short-form Alcohol Dependence Data Questionnaire (SADD), Drinking Related Internal-External Locus of Control Scale: (DRIE), and the Stages of Change Readiness and Treatment Eagerness Scale (SOCRATES). The data was co
... Show MoreThe Security Council has an active role in addressing international crises and dealing with their causes. The Libyan crisis is one of the most important real tests of the Security Council and its role in maintaining international peace and security, as the Council has proven so far an ineffective role in resolving the crisis and dealing withtheir causes, which has prolonged its duration and increased its complexities and dangerous repercussions, perhaps the most prominent of which is the threat of the recently achieved cease-fire and the formation of a new transitional government led by Abdel Hamid al-Dabaiba, the growing significant obstacles facing the political process, foremost of which is the continued presence of foreign forces , m
... Show Moreالخلاصة
يجمع المختصون أن ليس من نقد إلا وكان مُرحِّلا لنظرية لسانية إلى فضائه، فكان أثر اللسانيات السوسيرية، ومن ثم اللسانيات التوليدية التحويلية معروفا، ولم يكن هذا الأثر محدودا باللسانيين أو نقاد الأدب فحسب، بل امتد إلى الشعراء والجماليين أيضا. وفي هذا البحث سنتوقف عند أثر اللسانيات الوظيفية، وهو ما لم يتوقف عنده إلا قلة من المختصين. ولن نقف عند نقد الوظيفيين للشعر، بل سنقف عند نقدهم للرواية، بقراءة
... Show MoreThis research aims to present a proposed model for disclosure and documentation when performing the audit according to the joint audit method by using the questions and principles of the collective intelligence system, which leads to improving and enhancing the efficiency of the joint audit, and thus enhancing the confidence of the parties concerned in the outputs of the audit process. As the research problem can be formulated through the following question: “Does the proposed model for disclosure of the role of the collective intelligence system contribute to improving joint auditing?”
The proposed model is designed for the disclosure of joint auditing and the role
... Show MoreIn this paper, we introduce the concept of cubic bipolar-fuzzy ideals with thresholds (α,β),(ω,ϑ) of a semigroup in KU-algebra as a generalization of sets and in short (CBF). Firstly, a (CBF) sub-KU-semigroup with a threshold (α,β),(ω,ϑ) and some results in this notion are achieved. Also, (cubic bipolar fuzzy ideals and cubic bipolar fuzzy k-ideals) with thresholds (α,β),(ω ,ϑ) are defined and some properties of these ideals are given. Relations between a (CBF).sub algebra and-a (CBF) ideal are proved. A few characterizations of a (CBF) k-ideal with thresholds (α, β), (ω,ϑ) are discussed. Finally, we proved that a (CBF) k-ideal and a (CBF) ideal with thresholds (α, β), (ω,ϑ) of a KU-semi group are equivalent relations.
The study of the tendencies of scientific research in specialized journalism through the three specialized levels, specifically the third level. It is referred to be a monthly, quarterly or annual magazine that follows the publication of the researches for new studies which have come to in every specialization. it is directed to the highly educated and is almost an alternative book. Thus, the subject is specialized and the audience is specialized.
The study aims in both its survey and field section at knowing the type of researches and their classification and the form, gender and the use of foreign sources and their scientific tank and the geographical position in addition to knowing the opinions of researchers and their satisfa
... Show MoreNatural convection heat transfer is experimentally investigated for laminar air flow in a vertical circular tube by using the boundary condition of constant wall heat flux in the ranges of (RaL) from (1.1*109) to (4.7*109). The experimental set-up was designed for determining the effect of different types of restrictions placed at entry of heated tube in bottom position, on the surface temperature distribution and on the local and average heat transfer coefficients. The apparatus was made with an electrically heated cylinder of a length (900mm) and diameter (30mm). The entry restrictions were included a circular tube of same diameter as the heated cylinder but with lengths of (60cm, 120cm), sharp-edge and
... Show More