The present study was set to demonstrate the prevalence of toxoplasmosis infection and its effects on patients with systemic lupus erythematosus (SLE) through determining their serum levels of anti-dsDNA and IL-18 antibodies. For this purpose, the sera from 132 SLE and/or toxoplasmosis patients and 30 healthy women, were collected. The study sample was divided into four groups of SLE, toxoplasmosis, SLE coinfected with toxoplasmosis, and healthy control. Anti-Toxoplasma IgG antibodies were examined for all the samples using ELISA kit. The results showed a high mean level of anti-Toxoplasma IgG among SLE patients coinfected with toxoplasmosis (104.8792±12.31585pg/ml) in comparison to that in toxoplasmosis patients (91.1705±12.57746pg/ml). However, the mean value of anti-dsDNA antibodies showed significant (P≤0.01) elevation in SLE patients and SLE patients coinfected with toxoplasmosis (71.2134±9.22131pg/ml and 72.3699±9.67917 pg/ml, respectively), compared to those infected with toxoplasmosis only and healthy control. Furthermore, the IL-18 mean value in the sera of the studied patients showed significant (P≤0.01) elevation (418.4000±43.18072pg/ml) in SLE patients with toxoplasmosis in comparison to SLE patients (354.4400±35.29257pg/ml). The present investigation suggests that the levels of anti-Toxoplasma IgG antibodies seem to increase in patients with SLE.
A novel demountable shear connector for precast steel-concrete composite bridges is presented. The connector uses high-strength steel bolts, which are fastened to the top flange of the steel beam with the aid of a special locking nut configuration that prevents bolts from slipping within their holes. Moreover, the connector promotes accelerated construction and overcomes the typical construction tolerance issues of precast structures. Most importantly, the connector allows bridge disassembly. Therefore, it can address different bridge deterioration scenarios with minimum disturbance to traffic flow including the following: (1) precast deck panels can be rapidly uplifted and replaced; (2) connectors can be rapidly removed and replaced; and (
... Show MoreThe temperature control process of electric heating furnace (EHF) systems is a quite difficult and changeable task owing to non-linearity, time delay, time-varying parameters, and the harsh environment of the furnace. In this paper, a robust temperature control scheme for an EHF system is developed using an adaptive active disturbance rejection control (AADRC) technique with a continuous sliding-mode based component. First, a comprehensive dynamic model is established by using convection laws, in which the EHF systems can be characterized as an uncertain second order system. Second, an adaptive extended state observer (AESO) is utilized to estimate the states of the EHF system and total disturbances, in which the observer gains are updated
... Show MoreThe aim of this work is to detect the best operating conditions that effect on the removal of Cu2+, Zn2+, and Ni2+ ions from aqueous solution using date pits in the batch adsorption experiments. The results have shown that the Al-zahdi Iraqi date pits demonstrated more efficient at certain values of operating conditions of adsorbent doses of 0.12 g/ml of aqueous solution, adsorption time 72 h, pH solution 5.5 ±0.2, shaking speed 300 rpm, and smallest adsorbent particle size needed for removal of metals. At the same time the particle size of date pits has a little effect on the adsorption at low initial concentration of heavy metals. The adsorption of metals increases with increas
... Show More