In the current research, multiple mixing ratios of gamma -transitions of the energy levels 60𝑁𝑑 142−150 isotopes populated in 𝑁𝑑(𝑛, 𝑛 ˊ 60 142−150 ) 60𝑁𝑑 142−150 interaction are calculated using the constant statistical tensor (CST) method. The results obtained are, in general, in good agreement or consistent, within the experimental error, with the results published in the previously researches. Existing discrepancies result from inaccuracies in the experimental results of previous works. The current results confirm the validity of the constant statistical tenser method of calculating the values of mixing ratios and its predictability of errors in experimental results
Pregnancy pose an additional burden on the body of the mother so as to meet their needs and the needs of the fetus and the body's need to iron increases excessively during pregnancy and iron is an essential element for the formation of hemoglobin blood Either hemoglobin is the key ingredient for red blood cells which carries oxygen to parts of the body, alas, most of the pregnant women begin their pregnancy inadequate stocks of iron in their bodies, which does not cover their need and requirement of the fetus, especially in the second and third trimesters of pregnancy When you reach the mother to the period in which they did not have the adequate amount of iron to produce hemoglobin become the mother was anemic So emerged the problem of
... Show MoreThis work focuses on the preparation of pure nanocrystalline SnO2 and SnO2:Cu thin films on cleaned glass substrates utilizing a sol-gel spin coating and chemical bath deposition (CBD) procedures. The primary aim of this study is to investigate the possible use of these thin films in the context of gas sensor applications. The films underwent annealing in an air environment at a temperature of 500 ◦C for duration of 60 minutes. The thickness of the film that was deposited may be estimated to be around 300 nm. The investigation included an examination of the structural, optical, electrical, and sensing characteristics, which were explored across various preparation circumstances, specifically focusing on varied
... Show MoreThin films of (CuO)x(ZnO)1-x composite were prepared by pulsed laser deposition technique and x ratio of 0≤ x ≤ 0.8 on clean corning glass substrate at room temperatures (RT) and annealed at 373 and 473K. The X-ray diffraction (XRD) analysis indicated that all prepared films have polycrystalline nature and the phase change from ZnO hexagonal wurtzite to CuO monoclinic structure with increasing x ratio. The deposited films were optically characterized by UV-VIS spectroscopy. The optical measurements showed that (CuO)x(ZnO)1-x films have direct energy gap. The energy band gaps of prepared thin films
Forward-swept wings were researched and introduced to improve maneuverability, control, and fuel efficiency while reducing drag and they are often used alongside canards, to further enhance their characteristics. In this research, the effects of canard dihedral angles on the wing loading of a forward-swept wing in transonic flow conditions were studied, as the wing loading provides a measure of wing’s efficiency (lift/drag). A generic aircraft model from literatures was selected, simulated, and compared to, using CFD software ANSYS/Fluent where the flow equations were solved to calculate the aerodynamic characteristics. The research was carried at two different Mach numbers, 0.6 and 0.9, for five different canard dihedral angles which tra
... Show MoreThe flow in a manifolds considered as an advanced problem in hydraulic engineering applications. The objectives of this study are to determine; the uniformity qn/q1 (ratio of the discharge at last outlet, qn to the discharge at first outlet, q1) and total head losses of the flow along straight and rectangular loop manifolds with different flow conditions. The straight pipes were with 18 m and 19 m long and with of 25.4 mm (1.0 in) in diameter each. While, the rectangular close loop configuration was with length of 19 m and with diameter of 25.4 mm (1.0 in) also. Constant head in the supply tank was used and the head is 2.10 m. It is found that outlets spacing and manifold configuration are the main factors aff
... Show MoreIn this study, an unknown force function dependent on the space in the wave equation is investigated. Numerically wave equation splitting in two parts, part one using the finite-difference method (FDM). Part two using separating variables method. This is the continuation and changing technique for solving inverse problem part in (1,2). Instead, the boundary element method (BEM) in (1,2), the finite-difference method (FDM) has applied. Boundary data are in the role of overdetermination data. The second part of the problem is inverse and ill-posed, since small errors in the extra boundary data cause errors in the force solution. Zeroth order of Tikhonov regularization, and several parameters of regularization are employed to decrease error
... Show MoreThe ability of insurance companies to achieve goals depends on their ability to meet customers' requirements, and this requires them to identify target markets and respond to needs and wishes of the markets, the skill is to convince the company to operate what is in the interest of the customer if he is convinced the customer service provided to him, he would repeat to deal with, and where the cost of maintaining existing customers is less than the cost of attracting new customers, the insurance companies that is working hard to maintain their customers, the more customer satisfaction with the services provided has increased loyalty and weakened the ability of competitors lured.
&nbs
... Show MoreObjective : Sciatic nerve block (popliteal approach) and femoral N block is a new technique other than general anesthesia in below knee surgery because it provides adequate muscle relaxation, with good intraoperative and post-operative analgesia. Nefopam is non opioid, non-respiratory depressant and non-sedative was mixed with local anesthetics drug to study the effects. This study was done to compare the onset and duration of sensory and onset time and duration of action of motor block following administration of either bupivacaine alone with administration of bupivacaine and Nefopam in patients undergoing below knee lower limb surgeries under ultrasound guided regional anesthesia.
Methods: 100 patients with American society of anest