One of the main parts in hydraulic system is directional control valve, which is needed in order to operate hydraulic actuator. Practically, a conventional directional control valve has complex construction and moving parts, such as spool. Alternatively, a proposed Magneto-rheological (MR) directional control valve can offer a better solution without any moving parts by means of MR fluid. MR fluid consists of stable suspension of micro-sized magnetic particles dispersed in carrier medium like hydrocarbon oil. The main objectives of this present research are to design a MR directional control valve using MR fluid, to analyse its magnetic circuit using FEMM software, and to study and simulate the performance of this valve. In this research, a comprehensive literature review on the advancement of this technology provides valuable insight on MR valve design by previous researchers. The design of MR directional control valve, the construction of the valve and the principle of work are presented. The design of proposed MR single valve has enabled the development of the MR directional control valve. Design and finite elements analysis using FEMM software of the MR single valve and MR directional control valve were done to obtain the optimal design. The valve was fabricated and the experimental rig for valve test was developed. The experiment presentation for functional working principle of the valve and valve performance were shown. The results of the simulation results show that the valve works in controlling the direction and the speed of hydraulic actuators. The valve can be operated with variable flow rate by varying the electric current. It is found that the electric current is inversely proportional to the flow rate. High current produces low flow rate and vice versa. It does the work of the valves to proportionally control the hydraulic actuators. The valve can be operated as ON-OFF directional control valve as well as proportional directional control valve with meter-in or meter-out by changing electric connection.
A cost-effective and efficient detector was created to conduct thorough turbidimetric measurements by reaction of Co (II) ion with calcium ferro cyanide to form bright green particulate, using the method of continuous flow injection analysis, the use of NAG-5SX1-1D-SSP Analyzer in determining cobalt (II) ion in a test for the validity of the new design. The NAG-5SX1-1D-SSP Analyzer is composed of five irradiation sources of white snow leds having the diameter of 10 mm with one solar cell of 55 mm length, 13.5 mm width. Using a selector switch to select the optimum voltage to be used which was 2.7 VDC. Under conditions of optimization, cobalt (II) ion was determined at 0.005–20 mmol. L–1(n = 23) while linearity dynamic range 0.005–7 mm
... Show MoreNew, simple and sensitive batch and Flow-injecton spectrophotometric methods for the determination of Thymol in pure form and in mouth wash preparations have been proposed in this study. These methods were based on a diazotization and coupling reaction between Thymol and diazotized procaine HCl in alkaline medium to form an intense orange-red water-soluble dye that is stable and has a maximum absorption at 474 nm. A graphs of absorbance versus concentration show that Beer’s law is obeyed over the concentration range of 0.4-4.8 and 4-80 µg.ml-1 of Thymol, with detection limits of 0.072 and 1.807 µg.ml-1 of Thymol for batch and FIA methods respectively. The FIA procedure sample throughput was 80 h-1. All different chemical and physical e
... Show MoreThere is a growing interest in studying the effects of arthritis on a person's work productivity using a growing variety of outcome indicators.
To develop a valid and reliable shortened version of the Workplace Activity Limitation Scale 12 (WALS‐12) for assessing work productivity limitations in rheumatoid arthritis (RA) patients.
A cross‐sectional study involving 277 RA patients was conducted. An exploratory factor analysis on WALS‐12 was used for item reduction on the first sample. Then confirmatory factor ana
In this study, six square reinforced concrete flat plates with dimensions of (1500×1500×100) mm were tested under a concentrated load applied on a column located at the center of the slabs. One of these slabs was the control specimen, whereas, in the others, steel angles (steel collars) were used, fixed at the connection region between the slab and the column to investigate the effect of the presence of these collars on punching shear strength. Five thicknesses were used (4, 5, 6, 8, 10mm) with constant legs of angles (75×75) mm of the steel collars to investigate the effects on the punching shear resistance with respect to the control slab. The results of the experimental study show that the punching shear resistance increased b
... Show MoreFutsal and blind football are group games of a competitive nature due to their excitement, excitement, fun, and aesthetic goals with charming artistic touches. This explains the public's passion for these two games, whether healthy people or blind people play them, to expand their vision and knowledge. About these two games, a historical approach is presented about their origins, development, and how they became globally recognized competitive sports with unified rules and world championships at various levels. Studying the origin and global spread of both futsal and blind football and identifying the most prominent developments in the rules and tools for futsal and blind football. The most important findings were that both futsal and footb
... Show MoreThis paper numerically and theoretically investigates the optical and thermal performance of a parabolic trough collector PTC system. Many numerical simulations and theoretical analyses are conducted to demonstrate the influence of the receiver geometry and shifting from the focal position on the optical performance. The examined receiver geometries are circular, square, triangular, elliptical, and the new circular–square combined geometry is named as channel receiver. The thermal performance of PTC is examined for different volume flow rates theoretically in the range of (0.36 to 2.4 lpm). The results show that the best optical design is the channel receiver with an intercept factor of 84%, while the worst is the elliptical receiver with
... Show MoreIn this research, main types of optical coatings are presented which are used as covers for solar cells, these coatings are reflect the infrared (heat) from the solar cell to increase the efficiency of the cell (because the cell’s efficiency is inversely proportional to the heat), then the theoretical and mathematical description of these optical coatings are presented, and an optical design is designed to meet this objective, its optical transmittance was calculated using (MATLAB R2008a) and (Open Filters 1.0.2) programs
In this work, we carried out an experimental study of thedusty
plasma by taking the dust material Fe3O4 with radius of the any grain
0.1μm - 0.5μm. In experiment we use air in the vacuum chamber
system under different low pressure (0.1-1) Torr. The results
illustrated that the present of dust particles in the air plasma did not
effect on Paschen minimum which is 0.5 without dust and with Fe3O4
dusty grains.
The effect of Fe3O4 dust particles on plasma parameters can be
notice in direct current system in glow discharge region. The plasma
parameters which were studied in this work represent plasma
potential, floating potential,electron saturation current, temperatu