Preferred Language
Articles
/
bsj-700
Analysis of the performance of a fiber optic sensor used to measure the intensity of the electric field

In this research was conducted to provide a product to analyze the performance sensor fiber optic used to measure and feel the intensity of the electric field results showed obtained that use sensor long gives reactive high electric field strength and a high value for allergic sensor, but that is at the expense of reducing the intensity of the electric field that is detected

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
The Influence of No-Core Fiber Length on the Sensitivity in Fiber Optic Strain Sensor

The influence of sensing element length of no-core fiber strain sensor has been studied and experimentally demonstrated, four different lengths of 125 μm diameter no-core fiber is fused between two standard single-mode fibers and bi-directionally strained, the highest obtained sensitivity was around 16.37 pm με -1 which was exhibited in the shortest no-core fiber segment, to the best of our knowledge this is the first study of the influence of no-core fiber strain sensors length on sensor sensitivity. The proposed sensor can be used in many opto-mechanical applications such as, structural health monitoring, aerospace vehicles and airplane components monitoring.

View Publication Preview PDF
Publication Date
Fri Sep 15 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
Determine, Predict and Map Soil pH Level by Fiber Optic Sensor
Abstract<p>Soil pH is one of the main factors to consider before undertaking any agricultural operation. Methods for measuring soil pH vary, but all traditional methods require time, effort, and expertise. This study aimed to determine, predict, and map the spatial distribution of soil pH based on data taken from 50 sites using the Kriging geostatistical tool in ArcGIS as a first step. In the second step, the Support Vector Machines (SVM) machine learning algorithm was used to predict the soil pH based on the CIE-L*a*b values taken from the optical fiber sensor. The standard deviation of the soil pH values was 0.42, which indicates a more reliable measurement and the data distribution is normal.</p> ... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Mon Dec 05 2022
Journal Name
Baghdad Science Journal
Influence of Optical Fiber Diameters on the Performance of Surface Plasmon Resonance Sensor

In this research, a sensor for chemical solutions was designed and formed using optical fiber-based on a surface Plasmon resonance technology. A single-mode optical fiber with three different diameters (25, 45 and 65) µm was used, respectively.  The second layer of the low refractive fiber was replaced by gold, which was electrically deposited at 40 µm thickness. For each of the three types of optical fiber, different saline concentrations (different index of refraction) were used to evaluate the performance of the refractive index sensor (chemical sensor) by measuring its sensitivity and resolutions. The highest values we could get for these two parameters were 240mm/RIU, and 6*10-5 RIU respectively, when the diameter of a

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Performance of humidity sensor based on photonic crystal fiber interferometer

Photonic Crystal Fiber Interferometers (PCFIs) are greatly used
for sensing applications. This work presents the fabrication and
characterization of a relative humidity sensor based on Mach-
Zehnder Interferometer (MZI), which operates in reflection mode.
The humidity sensor operation based on the adsorption and
desorption of water vapour at the silica-air interface within the PCF.
The fabrication of this sensor is simple, it only includes splicing and
cleaving the PCF with SMF.PCF (LMA-10) with a certain length
spliced to SMF (Corning-28).
The spectrum of PCFI exhibits good sensitivity to humidity
variations. The PCFI response is observed for a range of humidity
values from (27% RH to 85% RH), the positi

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Dec 01 2002
Journal Name
Iraqi Journal Of Physics
Effect of the electric field on drilling Brass by Laser

The research include a pulsed Nd: YAG Laser with (300µs) pulse duration in the TEM00 mode at (1.06µm) wavelength for energies between (0.5-3) J was employed to drill Brass material which is use in industrial applications. The process of drill was assisted by an electric field. This resulted in an increase in the hole aspect ratio by the value (45%) and decrease in the hole taper by the value (25%) of its value under ordinary drilling conditions using the same input energy.

View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Using Six-Sigma to measure the quality performance of the Department of Statistics-University of Baghdad-Case Study

Abstract

            This research was to provide a definition of quality, dimensions and concepts, whether traditional or modern concept, as well as review the dimensions of quality in higher education and vision and mission with the overall objectives of the Statistics Department.

         After reviewing quality goals and purposes achieved as well as the mechanisms used to achieve them. and use standard Six-Sigma as one of the methodologies used in quality with the historical roots of using this methodology and methods applied and their definitions t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 04 2015
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Bronchogenic carcinoma in sample of Iraqi patients, Fiber optic bronchoscope findings

Background: Lung cancer is the leading cause of cancer deaths and its incidence is rising. The determination of histopathology and stage of primary lung carcinoma is crucial to develop appropriate treatment approach that affects morbidity and mortality. Fiber optic bronchoscope techniques for early detection of lung cancer are a promising tool as they might allow visualizing changes of early lung cancer and also permitting sampling for histological confirmation.
Objective: This study was intended to compare the fiber optic bronchoscopy findings and their anatomical locations with the histopathology types in patients with lung cancer.
Patient and Methods: A cross section study was conducted during the period

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 29 2020
Journal Name
Iraqi Journal Of Science
ANALYSIS of INTERFERENCE PATTERN of the FIBER INTERFEROMETER as a MOTION SENCOR

The production and analysis of an optimal interference pattern for the optical fiber interferometer of a 193.1THz continuous laser source was simulated by comparing the spectral spectroscopy of the two arms of interferometer to be used as a heterodyne detection in sensing the body range, speed, and direction of movement by delaying the time between the arms.

     The study showed that the fringe pattern can be sensed a range by the free spectral range FSR and the velocity by the fringe separation FS and the direction by the fringe spatial frequency FSF.

View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Jun 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Analysis of a Fixed Bed Absorber Used for the Removal of Pollutants from Water

View Publication Preview PDF
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
Designing and Constructing the Strain Sensor Using Microbend Multimode Fiber

The microbend sensor is designed to experience a light loss when force is applied to the sensor. The periodic microbends cause propagating light to couple into higher order modes, the existing higher order modes become unguided modes. Three models of deform cells are fabricated at (3, 5, 8) mm pitchand tested by using MMF and laser source at 850 nm. The maximum output power of (8, 5, 3)mm model is (3, 2.7, 2.55)nW respectively at applied force 5N and the minimum value is (1.9, 1.65, 1.5)nW respectively at 60N.The strain is calculated at different microbend cells ,and the best sensitivity of this sensor for cell 8mm is equal to 0.6nW/N.

View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref