Background: Piezosurgery improved the split approach by making it safer, easier, and less prone to complications when treating extremely atrophic crests. Densah drills, with their unique design, expand the ridge by densifying bone in a reverse, non-cutting mode. Objective: To assess the effectiveness of sagittal piezosurgery, which involves cutting bone to the full implant depth and then expanding it using osseodensification drills. We use this technique to expand narrow alveolar bones and simultaneously place dental implants in the maxillary and mandibular arches. Methods: Fourteen patients received 31 dental implants. The maxillary arch received 19, and the mandible received 12 dental implants. This study will include patients who have narrow alveolar bone ridges (2.5–4 mm). After marking the implant sites with a pilot drill, we used a piezoelectric surgery tip to cut the alveolar crest to the depth of the planned dental implant. We then sequentially used Versah Drills, accompanied by extensive irrigation using cooled, sterile normal saline, and finally inserted the implant into the subcrestal level. Results: This study revealed a significant difference in alveolar ridge width immediately after the procedure, and the significant change in the mandible was slightly higher than that in the maxillary arch. However, all implants in both jaws achieved successful osseointegration. Conclusions: The alveolar ridge width changed a lot more in the mandible than in the maxillary arch after the procedure. These two strategies work well together to properly and simply expand severely atrophied alveolar ridges without affecting bone healing or the osseointegration process.
This article deals with the approximate algorithm for two dimensional multi-space fractional bioheat equations (M-SFBHE). The application of the collection method will be expanding for presenting a numerical technique for solving M-SFBHE based on “shifted Jacobi-Gauss-Labatto polynomials” (SJ-GL-Ps) in the matrix form. The Caputo formula has been utilized to approximate the fractional derivative and to demonstrate its usefulness and accuracy, the proposed methodology was applied in two examples. The numerical results revealed that the used approach is very effective and gives high accuracy and good convergence.
In this paper, a theoretical investigation was suggested to study underwater wireless optical communication (UWOC) system based on multiple input–multiple output (MIMO) technique. The modulation schemes such as RZ-OOK, NRZ-OOK, 32-PPM and 4-QAM applied under different coastal water types. MIMO technique enabled the system to transmit data rate with longer distance link. The performance of the proposed system examined by BER and data rate as a metrics. Several impairments such as the types of water by the attenuation of coastal water and the distance link were taken into account for the transmission of the optical signal to appreciate the reliability of the MIMO technique. The theore
Objective: To assess the functional outcome, time to union, shoulder pain, blood loss, operative time, iatrogenic radial nerve injury, hospitalization, and infection. Methodology: It is a prospective randomized study on 30 patients with mid-shaft humerus fracture according to AO classification (1.2A1, 2, 3 and 1,2B) with functioning radial nerve. They were randomly dividing into two groups. Group A were treated by a closed antegrade interlocking nail, and group B treated by open reduction and locked compression plate fixation. The follow-up was up to 6 months, including time to union, shoulder pain, intraoperative blood loss, operative time and iatrogenic radial nerve injury. Functional outcome was assessed by quick DASH score. Resu
... Show MoreStudy showed structure of pecten oculi in the Kestrel Falco tinnunculus L.was
Pleated type and consisted of 17 folds which were thick. While in the Collared Dove
Streptopelia decaocto F. was Vaned type and consisted of 13 folds and it described
thin. The illustrated histological study of pecten oculi folds in the Kestrel and the
Collared Dove was composed of large number of capillaries, large blood vessels and
pigment cells which were few in Kestrel compare with the Collared Dove. The bridge
in the Kestrel and the Collared Dove pecten oculi was consisted of connective tissue,
many pigment cells, and contains on little capillaries and it linked the membrane to
the internal limiting membrane of the retina in the Kes
Background: The fracture of instruments within root canal during endodontic treatment is a common incidence, fracture because of fatigue through flexure occurs due to metal fatigue, this study aimed to assess the effect of curvature angle and rotational speed on the cyclic fatigue of different type of Endodontic NiTi Rotary Instruments and compare among them. Materials and method: Three types of rotary instruments with tip size 0.25: ProTaPer F2 (Densply, Malifier) Revo-S SU( 0.06 taper, MicroMega) and RaCe system (0.06 taper, FKG, Dentaire), Forty file of each instrument were used within two canals with angle of curvature (40 &60 )at two speed (250&400)RPM, twelve group were formed for all instruments(total number=120),ten file fo
... Show MoreBackground: The long term survival of dental implants is evaluated by the amount of crestal bone loss around the implants. Some initial loss of bone around dental implants is generally expected. There is reason to believe that reflecting a mucoperiosteal flap promotes crestal bone loss in the initial phase after an implant has been inserted. The surgical placement of a dental implant fixture is constantly changing and in recent years, there has been some interest in developing techniques that minimize the invasive nature of the procedure, with flapless implant surgery being advocated. The purpose of this study was to compare the radiographic level of the peri- implant bone after implant placement between traditional flapped surgery and f
... Show MoreThe results of the current study showed that the liver of H. javanicus appeared as large lobulated organ divided into six distinct lobes, that filled the cranial region and little extended to the middle region of abdominal cavity. On the other hand, liver of S. carolinensis laid against the diaphragm, occupied the cranial region of the abdominal cavity and consisted of five lobes. The liver is surrounded with a thin capsule of dense regular collagenous connective tissue and few numbers of smooth muscles fibers can be seen in the capsule that covered the squirrel liver. The liver parenchyma divided into a large number of interconnected hepatic lobules marked only by the abundant amount of connective tissue bordered the triads, and within the
... Show MoreHyperlipidemia is one of the most important factors leading to atherosclerosis and heart disease, therefore, this study conducted to examine the effect of two newly synthesized compounds[3-(5(ethylthio)-1,3,4-thiadiazol-2-yl)-2,3-dihydro-2-(3-nitrophenyl)benzo[1-3-e] thiazin-4-one (I) and 5(4dimethyl amino) benzylidene amino)-1,3,4-thiadiazole-2-thiol(II)] on the activities of creatine kinase(CK) and 3-hydroxy-3-methylglutaryl- CoA reductase (HMGR) in male Wister mice . Also to determine the type of inhibition of these compounds on the above enzymes .The study was carried out on sixty male Wister mice aged seven to eight weeks their weight ranged(180-200 g) . The mice were grouped as: group(1): control group (12 mice).Group(2):consisted
... Show MoreStrong acids were determined via the precipitation reaction of loaded copper (II) ion on strong cation exchange resin which in turn reacts with potassium hyxacyano ferrate (II). The attenuation effect of formed precipitate Cu2 [Fe (CN) 6] on (0 -180o) incident LED light was measurement via homemade AYAH 5SX4-ST-5D solar CFI analyser. Optimum parameters were 0.005M.L-1 [Fe(CN)6]-4 , flow rate of 2.4 mL.min-1 , sample volume 204 μL , sample purge time of 64 seconds was chosen, and 1.6 V for light intensity. A liner calibration graph of 0.005 -0.2 M.L-1 were obtains for HCl, HNO3, HCLO4 and H2SO4, with a linearity (r2 %) 96 -97 % and L.O.D based on gradual dilution of lowest concentration in calibration graph was 37.19 μg for HCl, 64.273
... Show MoreBackground: Many types of instruments and techniques are used in the instrumentation of the root canal system. These instruments and techniques may extrude debris beyond the apical foramen and may cause post-instrumentation complications. The aim of this study was to evaluate the amount of apically extruded debris resulted by using 4 types of nickel-titanium instruments (WaveOne, TRUShape 3D conforming files, Hyflex CM, and One Shape files) during endodontic instrumentation. Materials and methods: Forty freshly extracted human mandibular second premolar with straight canals and a single apex were collected for this study. All teeth were cut to similar lengths. Pre-weighted glass vials were used as collecting containers. Samples were randoml
... Show More