Preferred Language
Articles
/
9RecVI8BVTCNdQwCT2wF
Studying the responsivity and detectivity of GO/PSi/n-Si photo detector via drop casting technique
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jun 01 2025
Journal Name
Journal Of Physics: Conference Series
Studying the properties of linearly polarized modes in step index optical fibers at 1030 nm wavelength
...Show More Authors
Abstract<p>The growing demand for optical fibers is due to their superior the ability to transmit information with high efficiency and minimal loss across extensive distances. In this study, four optical fibers with core radii ranging from (2.05-5.05) μm, and with a numerical aperture of 0.1624 were analyzed. The modal properties of these fibers were calculated at a wavelength of 1030 nm using the RP Fiber Calculator software (free version 2025). Furthermore, the impact of increasing the core radius on these properties was examined. The results showed that multimode fibers are formed when the core radius is much larger than the wavelength used. In contrast, single-mode fiber is obtained when th</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Wed Nov 17 2021
Journal Name
Periodicals Of Engineering And Natural Sciences (pen)
Pearson coefficient matrix for studying the correlation of community detection scores in multi-objective evolutionary algorithm
...Show More Authors

View Publication
Scopus (7)
Crossref (2)
Scopus Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Baghdad Science Journal
Studying the Photodegradation of Congo Red Dye from Aqueous Solutions Using Bimetallic Au–Pd/TiO2 Photocatalyst
...Show More Authors

In this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest deg

... Show More
View Publication Preview PDF
Scopus (21)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Baghdad Science Journal
Studying the Photodegradation of Congo Red Dye from Aqueous Solutions Using Bimetallic Au–Pd/TiO2 Photocatalyst
...Show More Authors

In this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest degradation percent. In additio

... Show More
Scopus (21)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Baghdad Science Journal
Studying the Photodegradation of Congo Red Dye from Aqueous Solutions Using Bimetallic Au–Pd/TiO2 Photocatalyst
...Show More Authors

In this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest degradation percent. In additio

... Show More
View Publication
Scopus (21)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Tue Oct 13 2026
Journal Name
Misan Journal Of Academic Studies
Some of Parametric and Non Parametric Estimations for Circular Regression Model via Simulation
...Show More Authors

Circular data (circular sightings) are periodic data and are measured on the unit's circle by radian or grades. They are fundamentally different from those linear data compatible with the mathematical representation of the usual linear regression model due to their cyclical nature. Circular data originate in a wide variety of fields of scientific, medical, economic and social life. One of the most important statistical methods that represents this data, and there are several methods of estimating angular regression, including teachers and non-educationalists, so the letter included the use of three models of angular regression, two of which are teaching models and one of which is a model of educators. ) (DM) (MLE) and circular shrinkage mod

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 14 2024
Journal Name
Waste Disposal &amp; Sustainable Energy
Synthesis and characterization of nanocarbon from waste batteries via an eco-friendly method
...Show More Authors

View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Wed Jul 22 2026
Journal Name
Https://www.scopus.com/authid/detail.uri?authorid=57217105757
Bayesian Approach of Birnbaum-Saunders Quantile Regression via Jeffreys and Weakly Informative Priors
...Show More Authors

In this article we propose a general Bayesian estimation framework for the Birnbaum-Saunders Quantile Regression (BSQ) model which is used to analyze asymmetric and heterogeneous economic data. In this work, the novel aspect is the joint incorporation of several existing surrogate structures (with different degrees of approximation) and decision-theoretic loss functions (with direct impact on estimation performance trade-offs) under a common BSQ framework conducive to systematic testing of their effect on quantile estimation performance. We consider two previous prior specifications which are Jeffreys prior and weakly informative priors together with three loss functions quadratic, LINEX and the proposed quadratic-logarithmic loss function.

... Show More
View Publication
Publication Date
Mon Dec 25 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and Evaluation of Ketoprofen Nanosuspension Using Solvent Evaporation Technique
...Show More Authors

 

 

The effective surface area of drug particle is increased by a reduction in the particle size. Since dissolution takes place at the surface of the solute, the larger the surface area, the further rapid is the rate of drug dissolution. Ketoprofen     is class II type drug according to (Biopharmaceutics Classification System BCS) with low solubility and high permeability. The aim of this investigation was to increase the solubility and hence the dissolution rate by the preparation of ketoprofen     nanosuspension using solvent evaporation method. Materials like PVP K30, poloxamer 188, HPMC E5, HPMC E15, HPMC E50, Tween 80 were used as stabilizers in perpetration of differ

... Show More
View Publication Preview PDF
Crossref (11)
Crossref
Publication Date
Sun Aug 06 2023
Journal Name
Karbala International Journal Of Modern Science
Improving the BURT’s Sensitivity using Noise Calibration Unit via Crab Nebula Observations
...Show More Authors

Radio observations from astronomical sources like supernovae became one the most important sources of information about the physical properties of those objects. However, such radio observations are affected by various types of noise such as those from sky, background, receiver, and the system itself. Therefore, it is essential to eliminate or reduce these undesired noise from the signals in order to ensure accurate measurements and analysis of radio observations. One of the most commonly used methods for reducing the noise is to use a noise calibrator. In this study, the 3-m Baghdad University Radio Telescope (BURT) has been used to observe crab nebula with and without using a calibration unit in order to investigate its impact on the sign

... Show More
Preview PDF
Scopus Crossref