This study addressed the work stress sources and level of the communicator in public relations in governmental institutions in the United Arab Emirates. The importance of this study is the lack of studies on work stress of the communicator in public relations. The study aimed to investigate the work stress source Physical, individual, groups, organizational and Professional source which effect on the performance of communicator in public relations. The researcher used the descriptive approach and questionnaire as an essential tool for collecting information. Some of the important results of the study are The communicator in public relations facing stress in work by 42% which affect on his performance by average level. The organizational
... Show MoreTwo tests were carried out to measure the standard flat fan nozzles wear during a specific period of an accelerated wear procedure. The first test aimed at getting 10% increase in the flow rate compared to the nominal flow rate, which is the threshold to replace the nozzles according to the nozzles testing standards. The second test was to wear the nozzles intensively (100 hours of accelerated wear), which represents the use of nozzles beyond the allowed threshold. The results showed that the flow rate reached 1.31 l·min−1 (equal to 10% increase) for the tested nozzles after 35 hours of the wear test. For the second test, the 10% increase of the flow rate was r
PbxCd1-xSe compound with different Pb percentage (i.e. X=0,
0.025, 0.050, 0.075, and 0.1) were prepared successfully. Thin films
were deposited by thermal evaporation on glass substrates at film
thickness (126) nm. The optical measurements indicated that
PbxCd1-xSe films have direct optical energy gap. The value of the
energy gap decreases with the increase of Pb content from 1.78 eV to
1.49 eV.
In this research, (MOORA) approach based– Taguchi design was used to convert the multi-performance problem into a single-performance problem for nine experiments which built (Taguchi (L9) orthogonal array) for carburization operation. The main variables that had a great effect on carburizing operation are carburization temperature (oC), carburization time (hrs.) and tempering temperature (oC). This study was also focused on calculating the amount of carbon penetration, the value of hardness and optimal values obtained during the optimization by Taguchi approach and MOORA method for multiple parameters. In this study, the carburization process was done in temperature between (850 to 950 ᵒC) for 2 to 6
... Show MoreA streptococci has recognized as Streptococcus spp., associate with acute pharyngitis. S. pyogenes infection Has detected in the Hospital and Health Center in Tikrit city. Throat swabs sample has obtained and cultured on a sheep blood agar plate. Identification of S. pyogenes was performed by using the VITEK 2 automatic system. It detected of 50 samples from children included 25 were positive for S. pyogenes infection. were aged 10-35 years old and included 30 male and 20 female. . While 25 sample Negative of S. pyogenes infection (The control group included 25 clinically healthy children without S. pyogenes infection matched for age and sex with cases pateints). No significa
... Show MoreOut of 180 children, 60 (33.3%) have Amoebiasis infection as diagnosed by direct wet smear and Saturated Salt Solution (SSS). SSS method is more significant (P=0.001) in diagnosis of the disease. Number of children infected with Amoebiasis infection is higher in infants aged 1-6 months, but without any significant difference to ages 6-12 or 12-18 months. In contrast, infants aged 18-24 months are significantly differant (P=0.01) as the infection rate is 16.6%. Gender also is seen to be reduced in significance (P= 0.001) for females aged 18-24 months. Blood profile of the involved infants has shown a significant variation (P=0. 01) for all blood profile parameters (RBC (P=0.05), WBC (P=0.001), Lymphocytes (P=0.05), Granulated WBC (P=0.05),
... Show MoreThe modified Hummers method was applied to prepare graphene oxide (GO) from the graphite powder. Tin oxide nanoparticles with different loading (10-20 wt.%) supported on reduced graphene oxide were synthesized to evaluate the oxidative desulfurization efficiency. The catalyst was synthesized by the incipient wetness impregnation (IWI) technique. Different analysis methods like FT-IR, XRD, FESEM, AFM, and Brunauer-Emmett-Teller (BET) were utilized to characterize graphene oxide and catalysts. The XRD analysis showed that the average crystal size of graphene oxide was 6.05 nm. In addition, the FESEM results showed high metal oxide dispersions on the rGO. The EDX analysis shows the weight ratio of Sn is close to its theoretical weight.
... Show MoreThe research aims to identify the impact of the teaching methods Breathe test and imperative training method in learning some basic skills in Volleyball. The sample included 30 students of the first intermediate level from Al-Tawaia for boys / the public directorate of the education of Baghdad province – Al-Rasafa /2 ( The second). The samples are chosen randomly and divided into three groups : The systematic (Imperative method), first experimentary (training method), second experimentary (training method). Ten students are chosen for each group . The syllabus of the ministry of education is adopted on the systematic group while educational unites, which are prepared by the researcher, are used for the first and second experimenting group
... Show MoreElectrochemical Grinding (ECG) process is a mechanically assisted electrochemical process for material processing. The process is able to successfully machine electrically conducting harder materials at faster rate with improved surface finish and dimensional control. This research studies the effect of applied current, electrolyte concentration, spindle speed and the gap between workpiece and tool on hardness and material removal rate during electrochemical grinding for stainless steel 316. The characteristic features of the electrochemical grinding process are explored through Taguchi-design-based experimental studies. The better hardness can be obtained at 10 A of the current, 150 g/l of the electrolyte concentration, 0.3 mm of gap an
... Show More