Preferred Language
Articles
/
7hedeI0BVTCNdQwCFBR5
New Approach for Determination of Oxonium Ion in Inorganic Acids by Quenched Fluorescence of Analytically Interested Species via the Liberated Bromine Using Continuous Flow Injection Laser Diode Fluorimeter Analyser
...Show More Authors

A new method is characterized by simplicity, accuracy and speed for determination of Oxonuim ion in ionisable inorganic acid such as hydrochloric (0.1 - 10) ,Sulphuric ( 0.1 - 6 ),nitric ( 0.1 - 10 ), perchloric ( 0.1 - 7 ), acetic (0.1 - 100 ) and phosphoric ( 0.1 - 30 ) ( mMol.L-1 )acids. By continuous flow injection analysis. The proposed method was based on generation of bromine from the Bro-3-Br-- H3O+. Bromine reacts with fluorescein to quenches the fluorescence . A sample volume no.1 (31μl) and no.2 (35μl) were used with flow rate of 0.95 mL.min-1 using H2O line no.1as carrier stream and 1.3 mL.min-1 using fluorescein sodium salt line no.2. Linear regression of the concentration ( mMol.L-1 ) Vs quenched fluorescence gives a correlation coefficient of ( 89.33 -99.72 ) for all studies of acids in various parameters were optimized. The proposed method was applied successfully for the determination of Oxonium ion in commercial samples. Using paired t-test between the newly developed method and classical method; shows that there were no significant differences between either methods. On this basis the new method can be accepted as an alternative analytical method for determination of Oxonium ion in commercial samples.

View Publication
Publication Date
Mon Aug 01 2022
Journal Name
International Journal Of Hydrogen Energy
Perception of Mg adsorption on the BC2N nanotube as a anode for rechargeable Mg ion batteries
...Show More Authors

Owing to their cost-effectiveness and the natural abundance of magnesium, magnesium-ion batteries (MIBs) were introduced as encouraging alternatives to Lithium-ion batteries. Following the successful synthesis of carbon nano-tube, its B and N doped derivatives which were doped with B and N enjoyed the attention of researchers as novel anode materials (AM) for MIBs. Here, we investigated a BC2N nano-tube (BC2NNT) as an encouraging AM for MIBs. To have a deeper understanding of the electrochemical properties, cycling stability, specific capacity (SC) and the adsorption behavior of this nano-tube, first-principles density functional theory computations were performed. By performing NMR calculations, we identified two types of non-aromatic hexa

... Show More
View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Iraqi Journal Of Physics
Influence of Laser Energy on the Structural and Optical Properties of (CdO):(CoO) Thin Films Produced by Laser-Induced Plasma (LIP)
...Show More Authors

In this work, (CdO)1-x (CoO)x thin films were prepared on glass slides by laser-induced plasma using Nd:YAG laser with (λ=1064 nm) and duration (9 ns) at different laser energies (200-500 mJ) with ratio (x=0.5), The influence of laser energy on structural and optical properties has been studied. XRD patterns show the films have a structure of polycrystalline wurtzite. As for AFM tests results for the topography of the surface of the film, where the results showed that the grain size and the average roughness increase with increasing laser energy. The optical properties of all films were also studied and the results showed that the absorption coefficient for within the wavelength range (280-1100 nm), The value of the optical power gap fo

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Mon Feb 11 2019
Journal Name
Journal Of Pharmaceutical Sciences And Research
Design of experiments model for optimization of spectrophotometric determination of phenylephrine hydrochloride in pure and pharmaceutical formulations using p-bromanil
...Show More Authors

A simple, fast, inexpensive and sensitive method has been proposed to screen and optimize experimental factors that effecting the determination of phenylephrine hydrochloride (PHE.HCl) in pure and pharmaceutical formulations. The method is based on the development of brown-colored charge transfer (CT) complex with p-Bromanil (p-Br) in an alkaline medium (pH=9) with 1.07 min after heating at 80 °C. ‘Design of Experiments’ (DOE) employing ‘Central Composite Face Centered Design’ (CCF) and ‘Response Surface Methodology’ (RSM) were applied as an improvement to traditional ‘One Variable at Time’ (OVAT) approach to evaluate the effects of variations in selected factors (volume of 5×10-3 M p-Br, heating time, and temperature) on

... Show More
View Publication
Scopus
Publication Date
Sat Jun 30 2007
Journal Name
Al-kindy College Medical Journal
Diagnostic Approach of Atypical Cells in Effusion Cytology Using Computerized Image Analysis
...Show More Authors

Background: Cytology is one of the important diagnostic tests done on effusion fluid. It can detect malignant cells in up to 60% of malignant cases. The most important benign cell present in these effusions is the mesothelial cell. Mesothelial atypia can be striking andmay simulate metastatic carcinoma. Many clinical conditions may produce such a reactive atypical cells as in anemia,SLE, liver cirrhosis and many other conditions. Recently many studies showed the value of computerized image analysis in differentiating atypical cells from malignant adenocarcinoma cells in effusion smears. Other studies support the reliability of the quantitative analysisand morphometric features and proved that they are objective prognostic indices. Method

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 01 2017
Journal Name
Physics Letters A
Wake potential of swift ion in amorphous carbon target
...Show More Authors

The wake potential and wake phenomena for swift proton in an amorphous carbon target were studied by utilising various dielectric function formalisms, including the Drude dielectric function, the Drude–Lorentz dielectric function and quantum dielectric function. The Drude model results exhibited a damped oscillatory behaviour in the longitudinal direction behind the projectile; the pattern of these oscillations decreases exponentially in the transverse direction. In addition, the wake potential extends slightly ahead of the projectile which also depends on the proton coordinate and velocity. The effect of electron binding on the wake potential, characterised by the ratio to 0.1, has been studied alongside the Drude–Lorentz dielectric

... Show More
View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Pre-column dervatization of amino acids from nigella sativa L seed hydrolysates by reversed phase HPLC
...Show More Authors

A rapid and sensitive method for analysis of amino acid hydrolysates of nigella sativa L seed has been developed using O-phthaldialehyde(OPA ) as a pre-column derivatizing agent. OPA reagents in the presence of mercaptoethanol react rapidly with primary amino acids ( less than 60 sec.) to form isindole derivatives which easily separated with good selectivity on ODS column. Resolution of amino acid derivatives is carried out with a methanol gradient in 0.01 maqueous sodium acetate. pH 7.1 . The quantitation of amino acid derivatives is reproducible within an average relative deviation of + 1.4% the linearity for most amino acids were more than 0.9993 with detection limit of 0.2 ppm. 15 amino acid were detected in the analysis of

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Evergreen
Combustion Characteristics of a Free Piston Engine Linear Generator using Various Fuel Injection Durations
...Show More Authors

View Publication
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Kinetic- spectrophotometric Method for the Determination of Naringenin in Pure and Supplements Formulations
...Show More Authors

          Simple, cheap, sensitive, and accurate kinetic- spectrophotometric method has been developed for the determination of naringenin in pure and supplements formulations. The method is based on the formation of Prussian blue. The product dye exhibits a maximum absorbance at 707 nm. The calibration graph of naringenin was linear over the range 0.3 to 10 µg ml-1 for the fixed time method (at 15 min) with a correlation coefficient (r) and percentage linearity (r2%) were of 0.9995 and 99.90 %, respectively, while the limit of detection LOD was 0.041 µg ml-1. The method was successfully applied for the determination of naringenin in supplements with satisfac

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Mon Dec 11 2023
Journal Name
Journal Of Kufa For Chemical Sciences
Review of Analytical Methodologies for the Determination of Metronidazole and Trimethoprim in Environmental Samples
...Show More Authors

Antibiotics are essential for treating infectious diseases, but their overuse and adverse effects are raising concerns about global public health. The pervasiveness of antibiotic contamination in aquatic environments has drawn increased attention in recent years. The primary concern regarding the release of antibiotics into the environment is the potential for microorganisms to become resistant to antibiotics. This review article summarizes the analytical methods used to determine the presence of trimethoprim and metronidazole in various environmental samples. These antibiotics have traditionally been analyzed using tandem mass spectrometry or high-performance liquid chromatography coupled to mass spectrometry; fluorescence or ultrav

... Show More
Preview PDF
Publication Date
Mon Jun 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Determination of the Elastic and Viscous Behavior of Polycarbonate Melts at Different Temperatures and Their Relationship to the Steady State Viscosity via the Cox-Merz Rule
...Show More Authors

Rheological instrument is one of the basic analytical measurements for diagnosing the properties of polymers fluids to be used in any industry. In this research polycarbonate was chosen because of its importance in many areas and possesses several distinct properties.
Two kinds of rheometers devices were used at different range of temperatures from 220 ˚C-300 ˚C to characterize the rheological technique of melted polycarbonate (Makrolon 2805) by a combination of different investigating techniques. We compared the results of the linear (oscillatory) method with the non-linear (steady-state) method; the former method provided the storage and the loss modulus of melted polycarbonate, and presented the Cox-Merz model as well. One of the

... Show More
View Publication Preview PDF