Objective: To compare distal tibia nonunion plating and grafting with and without platelet-rich plasma (PRP) regarding union rate, union time and complications Conclusion: Combining PRP with autologous bone graft results in a higher union rate, less healing duration, less post-operative pain, and more callus formation. (Rawal Med J 202;45:629- 632). Methodology: In this prospective comparative study, 32 patients with nonunion tibia from July 2017 January 2019 were divided into two groups: group A (16 cases) were treated by plating and grafting with PRP and group B (16 cases) were treated by plating and grafting only. Keywords: Tibial nonunion, bone graft, plateletrich plasma. Results: There was higher union rate in group A related to group B (81% vs. 69%) but statistically not significant (p=0.256). Healing duration was significantly longer in group B (6.11 vs. 5.12) months(p=0.001). Regarding the postoperative pain, it was significantly less in groups A than group B. Conclusion: Combining PRP with autologous bone graft results in a higher union rate, less healing duration, less post-operative pain, and more callus formation. (Rawal Med J 202;45:629- 632).
Background: Fixed orthodontic appliances impede the maintenance of oral hygiene and result in plaque accumulation leads to enamel demineralization caused by acids produced by bacteria. Studies on plaque control strategies in orthodontic populations are limited. This might be caused by difficulties in the quantitative evaluation of dental plaque because the teeth have various levels of bracket coverage, and different tooth sizes and malocclusions, making the traditional categorical indices complex. The present study aims to evaluate the effect of different hygiene protocols on plaque quantity on bands with different attachments. Materials and method: Twenty patients had four bands within the orthodontic appliance. Then randomly divided into
... Show MoreNon-thermal plasmas have become popular as plasma technology has advanced in various fields, including waste management, aerospace technology, and medicinal applications. They can be used to replace combustion fuels in stationary hall motors and need little effort to keep running for longer periods of time. To improve overall system performance, non-reactive gases such as )Xe, Ar, and Kr) are utilized in pure or mixed form to generate plasma. Since DC glow discharge is a fundamental topic of importance, these gases have been researched. The paper concentrates on 2-D modeling and simulation. DC glow-discharge tubes are utilized with argon gas to create plasma and learn about its properties. The magnitude of the electron density, increases wi
... Show MoreIn this work, an experimental research on a low voltage DC magnetron plasma sputtering (0-650) volt is used for coating gold on a glass substrate at a constant pressure of argon gas 0.2 mbar and deposition time of 30 seconds. We focused on the effects of operating conditions for the system such as, electrode separation and sputtering current on coated samples under the influence of magnetic flux. Electron temperature and electrons and ions densities are determined by a cylindrical single Langmuir probe. The results show the sensitivity of electrode separation lead to change the plasma parameters. Furthermore, the surface morphology of gold coated samples at different electrode separation and sputtering current were studied by atomic forc
... Show MoreThe flow emission rate of hard photons from lowest order the QCD processes for quark-anti quark annihilation processes in plasma media at high temperatures (175, 200, 225, 250 and 275 MeV) have been study. In these framework photons, the flow photons emission is calculate according to quark-antiquark annihilation using the quantum chromodynamic theory and solves the ultrarelativistic equation with MATLAP program. Due to the results, we show increases flow photons rate with increases strength coupling and increases with increases temperature of media, it indicate that logarithmically divergent thermal effect on photons product. The critical temperature (Tc=155 to 195 MeV) effect on the quarks confined in hadronic matter phase, it is importan
... Show MoreBreast tumors patients generally have more oxidative stress than normal females. This was clear from a highly significant elevation (P<0.05) in malondialdehyde level in RBCs, serum and tissue of all patients groups with breast cancer as compared with control group. In this study we had found that free radicals in malignant breast tumors were higher than benign tumors, therefore the MDA might be used as a marker for prognosis of the disease.
Quantum dots (QDs) can be defined as nanoparticles (NPs) in which the movement of charge carriers is restricted in all directions. CdTe QDs are one of the most important semiconducting crystals among other various types where it has a direct energy gap of about 1.53 eV. The aim of this study is to exaine the optical and structural properties of the 3MPA capped CdTe QDs. The preparation method was based on the work of Ncapayi et al. for preparing 3MPA CdTe QDs, and hen, the same way was treated as by Ahmed et al. via hydrothermal method by using an autoclave at the same temperature but at a different reaction time. The direct optical energy gap of CdTe QDs is between 2.29 eV and 2.50 eV. The FTIR results confirmed the covalent bonding betwee
... Show MoreThis study aimed to compare lysyl oxidase-1 level in diabetic patients with and without renal dysfunction, that LOX-1 may be an indicator for the early stage of diabetic nephropathy (DN). In addition to finding it is a relationship with kidney functions in Iraqi diabetic patients with and without renal dysfunction. Blood was obtained from 25 healthy individuals as a control group (G1), 25 diabetic patients with renal dysfunction, and 25 diabetic patients without renal dysfunction. Age range 40-60 years for all subjects. BMI (25-27) Kg/m2 . The serum was used for the analysis of LOX-1, FBG, urea, creatinine and uric acid. Whole blood is used for the determination of HbA1C. Results of FBG and HbA1C revealed a significant increase in G2 and G
... Show MoreThe present researchers are trying to enhance the properties of paper sheet that used widely in many fields such as printing and packaging. The enhancement of paper quality is also possible to preserve paper documents of all kinds, as they are the true record, full of the history, achievements of the human being and the intellectual and cultural of the country. It is possible to improve its physical and mechanical properties and preserve them from damage through the use of some solutions of polymeric adhesives, which act as protective barriers against water and moisture penetration. The paper also has the advantage of porosity, which has been overcome by using three types of polymeric adhesives (Nitro Cellulose, Polyvinyl alcohol acetate, a
... Show MoreA new class of biologically active nanocomposites and modified polymers based on poly (vinyl alcohol) (PVA) with some organic compounds [II, IV, V and VI] were synthesized using silver nanoparticles (Ag-NPs). All compounds were synthesized using nucleophilic substitution interactions and characterized by FTIR, DSC and TGA. The biological activity of the modified polymers was evaluated against: gram (+) (staphylococcus aureus) and gram (-): (Es cherichia coli bacteria). Antimicrobial films are developed based on modified poly (vinyl alcohol) MPVA and Ag-NPs nanoparticles. The nanocomposites and modified polymers showed better antibacterial activities against Escherichia coli (Gram negative) than against Staphyloc
... Show MoreThis work introduces a new electrode geometry for making holes with high aspect ratios on AISI 304 using an electrical discharge drilling (EDD) process. In addition to commercially available cylindrical hollow electrodes, an elliptical electrode geometry has been designed, manufactured, and implemented. The principal aim was to improve the removal of debris formed during the erosion process that adversely affects the aspect ratio, dimensional accuracy, and surface integrity. The results were compared and discussed to evaluate the effectiveness of electrode geometry on the machining performance of EDD process with respect to the material removal rate (MRR,) the electrode wear rate (EWR), and the tool wear ratio (TWR). Dimensional features an
... Show More