Preferred Language
Articles
/
7BZeTYcBVTCNdQwCikJf
Effect of Surface Pavement Type on Traffic Noise
...Show More Authors

This paper investigates the issue of surface-type effects on traffic noise in Baghdad. Since the raw materials for both flexible and rigid paving are available from local sources, the decision on selecting the type of paving which depends on the budget of the project and the road's importance and function. Knowing that for high traffic volumes and a high percentage of heavy vehicles, rigid pavement is more suitable compared to flexible pavement. In Baghdad, some highways consist of flexible pavement and others of combined pavement (flexible segments and rigid segments), so the study of the effect of surface type on traffic noise becomes an important matter. This study selected three highways: one with flexible pavement and two with combined pavement. The results showed that the traffic noise generated by traffic on rigid pavement generates more noise than traffic on the flexible pavement by about 2 dBA. A prediction model was generated to predict traffic noise depending on five variables (vehicle speed, traffic volume, skid number, distance between the edge of the inner lane and the sound level meter, and surface type). The measured traffic noise levels ranged from 73.23 to 82.86 dBA, which exceeded the permitted limits compared to the permissible Iraqi standards.  

Crossref
Preview PDF
Quick Preview PDF
Publication Date
Wed Apr 12 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Thickness on the Electrical Conductivity and Hall Effect Measurements of (CIGS) Films
...Show More Authors

   The influence of different thickness (500, 1000, 1500, and 2000) nm on the electrical conductivity and Hall effect measurements have been investigated on the films of copper indium gallium selenide CuIn1-xGaxSe2 (CIGS) for x= 0.6.The films were produced using thermal evaporation technique on glass substrates at R.T from (CIGS) alloy.     The electrical conductivity (σ), the activation energies (Ea1, Ea2), Hall mobility and the carrier concentration are investigated and calculated as function of thickness. All films contain two types of transport mechanisms of free carriers, and increase films thickness was fond to increase the electrical conductivity whereas the activation energy (Ea) would vary with f

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Global Pharma Technology
Serum levels of cross-linked n-telopeptide of Type i collagen before and after non-surgical periodontal therapy in type 2 diabetic patients with chronic periodontitis
...Show More Authors

Background: Diabetes mellitus is a major risk factor for chronic periodontitis (CP) and hyperglycemia has an important role in the enhancement of the severity of the periodontitis. It has been reported that the progression of CP causes shifting of the balance between bone formation and resorption toward osteoclastic resorption, and this will lead to the release of collagenous bone breakdown products into the local tissues and the systemic circulation. Cross-linked N-telopeptide of type I collagen (NTx) is the amino-terminal peptides of type I collagen which is released during the process of bone resorption. This study was conducted to determine the effects of nonsurgical periodontal therapy on serum level of NTx in type 2 diabetic patients

... Show More
Publication Date
Mon Dec 11 2017
Journal Name
Al-khwarizmi Engineering Journal
ptimization the Parameters of Magnetic Abrasive Process Using Taguchi Method to Improve the Surface Roughness
...Show More Authors

Abstract  

Magnetic abrasive finishing (MAF) process is one of non-traditional or advanced finishing methods which is suitable for different materials and produces high quality level of surface finish where it uses magnetic force as a machining pressure. A set of experimental tests was planned according to Taguchi orthogonal array (OA) L27 (36) with three levels and six input parameters. Experimental estimation and optimization of input parameters for MAF process for stainless steel type 316 plate work piece, six input parameters including amplitude of tooth pole, and number of cycle between teeth, current, cutting speed, working gap, and finishing time, were performed by design of experiment

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
In Vitro Comparative Assessment of Composite Nanoleakage Using Various Dentine Surface Treatments
...Show More Authors

Background: The treatment of dental tissues proceeding to adhesive procedures is a crucial step in the bonding protocol and decides the clinical success ofrestorations. This study was conducted in vitro, with the aim of evaluating thenanoleakage on the interface between the adhesive system and the dentine treated by five surface modalities using scanning electron microscopy and energydispersiveX-ray spectrometry. Materials and methods: Twenty five extracted premolars teeth were selected in the study. Standardized class V cavities were prepared on the buccal and lingual surfaces then the teeth divided into five main groups of (5 teeth in each group n=10) according to the type of dentine surface treatment that was used: Group (A): dentine was

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Experimental and Numerical Analysis of Laser Surface Melting by Using Enthalpy Method
...Show More Authors
Abstract<p>In this study, experimental and numerical applied of heat distribution due to pulsed Nd: YAG laser surface melting. Experimental side was consists of laser parameters are, pulse duration1.3<italic>ms</italic>, wavelength 1064nm, laser energies 1.5, 2. 6 and 4.3 J, laser beam diameter is 0.6 mm and spot diameter 0.78 mm was applied a low carbon steel type St37 with a dimension 10, 10, 3 mm, length, width and thickness respectively. Numerical analysis side consist of a mathematical model and calculating a thermal cycle by using equation in the enthalpy method applied to determine the cooling rate in fusion zone. The simulation by using the enthalpy method, applied on conduction heat transfer </p> ... Show More
View Publication Preview PDF
Scopus (7)
Crossref (3)
Scopus Crossref
Publication Date
Mon Jul 14 2025
Journal Name
Journal Of Engineering
Technological Analysis of Flat Surface Conditions by Magnetic Abrasive Finishing Method (MAF)
...Show More Authors

This study introduced the effect of using magnetic abrasive finishing method (MAF) for finishing flat surfaces. The results of experiment allow considering the MAF method as a perspective for finishing flat surfaces, forming optimum physical mechanical properties of surfaces layer, removing the defective layers and decreasing the height of micro irregularities. Study the characteristics which permit judgment parameters of surface quality after MAF method then comparative with grinding

View Publication
Publication Date
Wed Sep 20 2023
Journal Name
International Journal Of Dentistry
Improving Surface Properties of PEEK for Dental Applications by Using Piranha Solution
...Show More Authors

Background. “Polyetheretherketone (PEEK)” is a biocompatible, high-strength polymer that is well-suited for use in dental applications due to its unique properties. However, achieving good adhesion between PEEK and hydrophilic materials such as dental adhesives or cement can be challenging. Also, this hydrophobicity may affect the use of PEEK as an implant material. Surface treatment or conditioning is often necessary to improve surface properties. The piranha solution is the treatment of choice to be explored for this purpose. Methods. PEEK disks of 10 mm diameter and 2 mm thickness were used in this study. Those samples were divided into five groups (each group has five samples). The first is the control group, in which no

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Surface Modification of Ti-6Al-4V Alloy by Glow Discharge-Plasma Nitriding
...Show More Authors

Titanium alloy (Ti-6Al-4V) samples were nitrided in low pressure (1.3, 3 mbar) dc-glow discharge plasmas of nitrogen. The treating time was 5, 10 and 15 hour and the temperatures range of the samples during the nitriding process was close to 800oC. The obtained microstructures of the nitride layers were studied by x-ray diffraction and optical microscopy. The ε –Ti2N, ζ-Ti3N3-x and η-Ti3N2-x.phases were formed and addition to the solid solution of nitrogen in titanium, α (Ti,N). Micro hardness measurements exhibit an increment for the Ti-alloy specimens which nitrided at 800oC for 10 and 15h.Corrosion measurements were obtained for the Ti-6Al-4V alloy in Ringer solution after plasma nitriding. The clear improving in the corrosion r

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 17 2019
Journal Name
Baghdad Science Journal
Study of Aerodynamic Surface Roughness for Baghdad City Using Signal-Level Measurements
...Show More Authors

Roughness length is one of the key variables in micrometeorological studies and environmental studies in regards to describing development of cities and urban environments. By utilizing the three dimensions ultrasonic anemometer installed at Mustansiriyah university, we determined the rate of the height of the rough elements (trees, buildings and bridges) to the surrounding area of the university for a radius of 1 km. After this, we calculated the zero-plane displacement length of eight sections and calculated the length of surface roughness. The results proved that the ranges of the variables above are ZH (9.2-13.8) m, Zd (4.3-8.1) m and Zo (0.24-0.48) m.

View Publication Preview PDF
Scopus (9)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Baghdad College Of Dentistry
In Vitro Comparative Assessment of Composite Nanoleakage Using Various Dentine Surface Treatments
...Show More Authors

Background: The treatment of dental tissues proceeding to adhesive procedures is a crucial step in the bonding protocol and decides the clinical success ofrestorations. This study was conducted in vitro, with the aim of evaluating thenanoleakage on the interface between the adhesive system and the dentine treated by five surface modalities using scanning electron microscopy and energydispersiveX-ray spectrometry. Materials and methods: Twenty five extracted premolars teeth were selected in the study. Standardized class V cavities were prepared on the buccal and lingual surfaces then the teeth divided into five main groups of (5 teeth in each group n=10) according to the type of dentine surface treatment that was used: Group (A): dentine was

... Show More
View Publication Preview PDF
Crossref (2)
Crossref