In this study, a new type of circulating three-phase fluidized bed reactor was conducted by adding a spiral path and was named as spiral three-phase fluidized bed reactor (TPFB-S) to investigate the possibility for removing engine oil (virgin and waste form) from synthetic wastewater by using Ricinus communis (RC) leaves natural and activated by KOH. The biosorption process was conducted by changing particle diameter in the range 150–300 and 300–600 µm, liquid flow rate in the range 2.5–4.5 L/min and gas flow rate in range of 0–1 L/min, while other parameters initial oil emulsion concentration, pH, adsorbent concentration, agitation speed and contact time were kept constant at 2000 mg/L, 2,400 mg/L, 200 rpm and 90 min, respectively. Both FTIR and SEM tests showed that the Ricinus communis surface contains of active and strong groups; therefore, it shows a morphological characteristic of interest. The tests of FTIR and SEM explained that the adsorbent solid texture consists of negative valences that related to strong and active groups like carboxyl and hydroxyl groups. Furthermore, the results showed that the removal efficiency reaches about 91 and 98% for both virgin and waste oil at 150–300 µm particle size, 3.5 l/min liquid phase flow rate and 1 L/min air flow rate and for 90 min by using natural and activated form of RC leaves, respectively. In addition, results revealed that 95% of oil was recovered from the adsorbent by using 150mL/L of hexane. Finally the results concluded that TPFB-S has a better performance than the traditional fluidized bed, where the removal efficiency was enhanced by about 23% and 17% for removing virgin oil emulsion from aqueous solution by natural and activated form of adsorbent, respectively.
This study aims to evaluate the influence of the air abrasion of dentin on the shear bond strength of lithium disilicate using three different types of luting cements. Sixty cylindrical specimens were milled from lithium disilicate CAD/CAM blocks (IPSe.max CAD). Sixty sound human maxillary premolar teeth were decoronated to the level of peripheral dentin, then randomly divided into three groups according to the type of luting cement used for the cementation of the lithium disilicate specimens (n = 20); Group A: Glass ionomer cement (Riva Self- Cure); Group B: Adhesive resin cement (Rely X Ultimate); Group C: Self-adhesive resin cement (Rely X U200). Each group was then further subdivided into two subgroups (n=10); Subgroups AI, BI, and CI,
... Show MoreThe study is about Maxwell , three dimensions of non – Newtonian fluid. Method of th Homotopy applied to analysis mass transfer and heat with thermophoresis effects. (Sc), Impact of therrmophoretic (𝜏), magnetic (M), Biot (γ), radiation (Rd),Schmidt Prandtle (Pr) parameters and ratio parameter(β) on concentration, temperature are offered in the paper.
The current research discusses the jurisprudence of the argumentative meaning in the Qur’an, and it is one of the general methods of responses in the Qur’an, as well as the argumentative approach to the recitations of the readers and directing their meanings. I have chosen a model for three verses from Surat Al-An’am, in which there are seven frequent recitations and seven odd ones, on a topic related to theology and faith; It forms the centerpiece of the argument verses in Surat Al-An'am; It contains the jurisprudence of dealing with infidels and dissenters, turning away and forbidding insulting what they claim besides God in the event of corruption, and God Almighty’s decree and wisdom in the occurrence of unbeli
... Show MoreThis study aims to assess the removal efficiency andestablish the BOD5 and COD statisticalcorrelation of the sewage flowing in Al-Diwaniyah wastewater treatment plant in Iraq during the study period (2005-2016). The strength of the influent wastewater entering the plant varied from medium to high in strength. High concentrations of BOD5 and COD in the effluent were obtained due to the poor performance of the plant. This was observed from the BOD5 /COD ratios that did not confirm with the typical ratios for the treated sewage. To improve the performance of this plant, regression equations for BOD5 and COD removal percentages were suggested which can be used to facilitate evaluation of liquid waste and optimal control process. The equations
... Show MoreThis study aimed at comparing the performance of vertical, horizontal and hybrid subsurface flow systems in secondary treatment for the effluent wastewater from the primary basins at Al-Rustumia wastewater treatment plant, Baghdad, Iraq. The treatments were monitored for six weeks while the testsduration were from 4 to 12 September 2018 under continuous wastewater feeding for chemical oxygen demand (COD), total suspended solid (TSS),ammonia-nitrogen(NH4-N) and phosphate (PO4-P) in comparison with FAO and USEPA standards for effluent discharge to evaluate the suitability of treated water for irrigation purposes. Among the systems planted with Phragmites Australia, the hybrid subsurface flow system which cons
... Show More120 samples were collected from children (ages between new born and 10 years) who infected with oral thrush. The results revealed that the Minimum Inhibitory Concentration (MIC) and Minimum Fungicidal Concentration (MFC) of extracted oil of lemon grass against C.albicans, C.tropicalis, C.keyfr, C.glabrata and C.guilliermondii were 1.25,1.25,1.25,2.5 and 2.5µl/ml and 2.5, 2.5, 2.5, 5 and 5 µl /ml respectively. while the (MIC) and (MFC) for the extraction oil of thyme against C.albicans, C.tropicalis, C.keyfr, C.glabrata and C.guilliermondii were 0.6, 0.6, 1.25, 1.25, and 1.25µl/ml and 1.25, 1.25, 2.5, 2.5, and 2.5µl/ml respectively . While the value of (MIC) and (MFC) for Nystatin against Candida species were 32 and 64 µg
... Show MoreGas and downhole water sink assisted gravity drainage (GDWS-AGD) is a promising gas-based enhanced oil recovery (EOR) process applicable for reservoirs associated with infinite aquifers. However, it can be costly to implement because it typically involves the drilling of multiple vertical gas-injection wells. The drilling and well-completion costs can be substantially reduced by using additional completions for gas injection in the oil production wells through the annulus positioned at the top of the reservoir. Multi-completion-GDWS-AGD (MC-GDWS-AGD) can be configured to include separate completions for gas injection, oil, and water production in individual wells. This study simulates
FG Mohammed, HM Al-Dabbas, Iraqi journal of science, 2018 - Cited by 6