Preferred Language
Articles
/
6hZTZIoBVTCNdQwCxpz4
Implementation and characterization of coating pure titanium dental implant with sintered β-TCP by using Nd:YAG laser
...Show More Authors

Objectives This work presents laser coating of grade 1 pure titanium (Ti) dental implant surface with sintered biological apatite beta-tricalcium phosphate (β-TCP), which has a chemical composition close to bone. Materials and methods Pulsed Nd:YAG laser of single pulse capability up to 70 J/10 ms and pulse peak power of 8 kW was used to implement the task. Laser pulse peak power, pulse duration, repetition rate and scanning speed were modulated to achieve the most homogenous, cohesive and highly adherent coat layer. Scanning electron microscopy (SEM), energy dispersive X-ray microscopy (EDX), optical microscopy and nanoindentation analyses were conducted to characterise and evaluate the microstructure, phases, modulus of elasticity of the coating layer and calcium-to-phosphate ratio and composition. Results showed that the laser power and scanning speed influenced coating adherence. The cross-sectional field-emission scanning electron microscopy images at low power and high speed showed poor adherence and improved as the laser power increased to 2 kW. Decreasing the scanning speed to 0.2 mm/s at the same power of 2 kW increased adherence. EDX results of the substrate demonstrated that the chemical composition of the coat layer did not change after processing. Moreover, the maps revealed proper distribution of Ca and P with some agglomeration on the surface. The sharp peaks on the X-ray diffraction patterns indicated that β-TCPs in the coat layer were mostly crystalline. The elastic modulus was low at the surface and increased gradually with depth to reach 19 GPa at 200 nm; this value was close to that of bone. The microhardness of the coated substrate increased by about 88%. The laser pulse energy of 8.3 J, pulse peak power of 2 kW, pulse duration of 4.3 min, repetition rate of 10 Hz and scanning speed of 0.2 ms−1 yielded the best results. Conclusion: Both processing and coating have potential use for dental implant applications.

Scopus Clarivate Crossref
View Publication
Publication Date
Sat Jun 01 2024
Journal Name
Results In Materials
Fabrication and characterization of mesoporous calcium silicate and silver-incorporated mesoporous calcium silicate nanoparticles with low cytotoxicity and antibacterial properties as a dental biomaterial
...Show More Authors

View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Jun 01 2022
Journal Name
Optik
High-purity narrow emission line display of titanium dioxide nanoparticles in laser dyes as random gains
...Show More Authors

In this work, the dyes Rhodamine B and Coumarin 102 containing titanium dioxide nanoparticles were used as scattering centers to fabricate a random gain medium. The laser dye was dissolved in hexanol and methanol solvent respectively. The titanium dioxide nanoparticles were synthesized by DC reaction magnetron spraying technique. The random-gain medium was made by adding 2.5 mg of titanium dioxide nanoparticles to Rhodamine and coumarin 102 dyes by coating the glass cell with two-sided titanium dioxide with high spectral efficiency and low production cost. A narrow line optical emission was detected at 565 nm for Rhodamine B and 534 nm for coumarin 102, where it was found that rhodamine B dye has FWHM 8 nm and coumarin dye 102 has FWHM 9 nm

... Show More
View Publication
Scopus (9)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Tue Jan 17 2023
Journal Name
Karbala International Journal Of Modern Science
Biofunctionalization of polyetheretherketone implant material by bone-forming peptide-2 immobilization
...Show More Authors

Polyetheretherketone (PEEK) has favorable biomechanical properties to be used as an implant material. Unfortunately, it is hydrophobic and does not promote cellular adhesion, which could result in poor integration with bone tissue. Bio-functionalization of PEEK surface with osteogenic peptides derived from bone extracellular matrix proteins is an exciting approach to encourage bone formation around the implant. In the current study, bone-forming peptide-2 was immobilized on PEEK surface using two different methods, using dopamine and a diglycidyl ether as conjugate compounds, respectively. Peptide quantification test revealed that the two strategies resulted in the most amount of peptides were attached with 0.5 mM concentration and no furth

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (4)
Scopus Crossref
Publication Date
Thu Mar 30 2023
Journal Name
Iraqi Journal Of Science
Characterization of Laser induced cadmium plasma in air
...Show More Authors

In this paper, the fundamental harmonic of a Nd:YAG laser (Q-switched 1064nm wavelength, 1 Hz repetition rate and 9 ns pulse duration) has been used for the ablation of cadmium samples in air at atmospheric pressure and the generation of the cadmium plasma. The experimentally observed lines of cadmium plasma emission have been used to calculate the plasma parameters such as (electron temperature (TReR), electron density (nReR), Debye length (λRDR) and plasma frequency (ωRpR)). Line pair ratio of neutral species have been used for the electron temperature and electron density measurements. Plasma parameters were studied as a functions of laser pulse energy.

View Publication Preview PDF
Publication Date
Wed Apr 01 2015
Journal Name
Journal Of Engineering
Software Implementation of Binary BCH Decoder Using Microcontroller
...Show More Authors

In this paper a decoder of binary BCH code is implemented using a PIC microcontroller for code length n=127 bits with multiple error correction capability, the results are presented for correcting errors up to 13 errors. The Berkelam-Massey decoding algorithm was chosen for its efficiency. The microcontroller PIC18f45k22 was chosen for the implementation and programmed using assembly language to achieve highest performance. This makes the BCH decoder implementable as a low cost module that can be used as a part of larger systems. The performance evaluation is presented in terms of total number of instructions and the bit rate.

 

 

View Publication Preview PDF
Publication Date
Wed Sep 10 2014
Journal Name
International Journal Of Computer Applications
Design and Implementation of Appliance Controller using Traditional or Smart Phone
...Show More Authors

Mobile phones are widely used nowadays, for different application such as wireless control and monitoring due to its availability and ease of use. The implemented system is based on "global system mobile (GSM)" network by using "short message service (SMS)". The design mainly contains a GSM modem and interfacing unit circuit with microcontrollers. This system could control up to eight different electrical devices such as light, Air conditioner, washing machine and many more applications which needed in daily life in different area (House, Office, or factory, etc.). The control is done by sending a specific SMS messages from traditional or smart phone. The controlling devices are restricted to a pre-defined phone number and are set in the so

... Show More
View Publication
Publication Date
Tue Feb 28 2023
Journal Name
Iraqi Journal Of Science
The Effect of Diode Laser on Viability and Antibiotic Sensitivity of Streptococcus mutans Isolated From Dental Caries
...Show More Authors

Streptococcus mutans is one of the major cariogenic microbial flora. In an attempt to determine the mutagenic effect of diode laser on the viability and antibiotic sensitivity of this bacteria; A total of 30 samples were collected from dental caries. The isolates were identified using by conventional identification methods and confirmed using VITEK2 system. Twenty-one isolates were recorded as Streptococcus spp and ten of them were identified as Streptococcus mutans. Antibiotic susceptibility profile for Streptococcus mutans isolates against ten antibiotics was tested. The results revealed that all the isolates were resistant to cefixime and cephaloth

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
The Combined Effect of Q-Switched Nd:YAG Laser (532 Nm) and Safranin O on the Growth of Pseudomonas Aeruginosaand its Susceptibilityto Antibiotics and Pyocyanin Production
...Show More Authors

Twenty five samples out of sixty wound swabs taken from burn patients were identified as P. aeruginosabacteria by conventional methods. Antibiotics susceptibility tests were performed against thirteen antibiotics. P. aeruginosa samples were treated with 0.5 mg/ml of Safranin O solution then irradiated with 532nm Q-switched Nd:YAG laser at four energy densities (0.324, 0.704, 1.380, and 1.831 J/cm2) for different times of 5, 8 and 11 minutes with 5Hz repetition rate. The viability, susceptibility to antibiotic and production of pyocyanin were determined before and after irradiation. The results showed that the number of CFU/ml of P. aeruginosa decreased with increasing the dose of irradiation. Complete killing of cells was observed at 1.8

... Show More
View Publication Preview PDF
Publication Date
Mon Aug 14 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Using Low Level Laser (LLL for Treatment of Infected Mice with Carcinoma by Activating the Lymph Node Action without Drugs
...Show More Authors

Regional immune response with mammary gland carcinoma was
studied statistically. However, the prognostic value remains
conflicting. Thirty mice were used in this study which infected
were with mammary gland carcinoma. The tumor size of the animals
under study were measured before and after laser irradiation by using
a vernier and compared these results were with that of non irradiated
animals with laser (control group)
The aim of this study was to evaluate the effect of low level laser
therapy (LLLT) on increasing the response of immune system by
stimulating the lymph node action to decrease the cancer cell activity
and then decreasing the tumor size of an infected mice.
The results of the gross observati

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Craniofacial Surgery
Is Orbital Floor Reconstruction With Titanium Mesh Safe?
...Show More Authors

View Publication
Scopus (11)
Crossref (13)
Scopus Clarivate Crossref