Preferred Language
Articles
/
6Rb8R4oBVTCNdQwCZ5KR
OPTIMIZATION OF PLASMA-ASSISTED DESORPTION/IONIZATIONMASS SPECTROMETRY FOR ANALYSIS OF IBUPROFEN
...Show More Authors

In medical practice, nonsteroidal anti-inflammatory drugs (NSAIDs) are often used to treat osteoarthritis and rheumatoid arthritis. Ibuprofen is a well-known NSAID, analgesic, and antipyretic medication. This chemical is an active ingredient of several oral medications that are offered in tablet, gel pellet, and syrup forms and has higher efficacy, tolerance, and side effect rates than other compounds, including pyrazolone derivatives. We present a unique plasma-assisted desorption/ionization mass spectrometry (PADI-MS) approach for improving pharmaceutically important solids using an ibuprofen tablet as a model solid sample. The goal of the study is to create an innovative mass spectrometric method that could be used for quick and accurate analysis in the development of pharmaceutically relevant compounds. Sniffer tubes were used to route sample ions into a single quadrupole MS, with each acquisition lasting for 1 minute. Without any prior preparation, samples of ibuprofen tablets were directly exposed to PADI plasma for one minute at an atmosphere pressure. The approach is rapid, easy to use, and needs little to no sample preparation. In this study, the settings were improved by optimization of several parameters, such as plasma power, plasma-to-sample distance, and inner/outer flows of helium carrier gas, which were found to be 8 W, 2 mm, and 284 mL/min, respectively. The PADI-MS method provides a real-time information about structural features on the compounds. Ibuprofen tablets were used as a paradigm for pharmaceutically significant materials and direct PADI-MS analysis without a preliminary sample -treatment appeared to be successful: according to PADI-MS data a medication can be examined after one minute of plasma exposure.

Preview PDF
Quick Preview PDF
Publication Date
Fri May 15 2020
Journal Name
Egyptian Journal Of Chemistry
Application of Response Surface Methodology for Optimization of Phenol Removal from Simulated Wastewater using Rotating Tubular Packed bed Electrochemical Reactor
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Iraqi Journal Of Physics
The Thermal Properties of Gliding arc Plasma Produced by Laboratory Reverse Vortex Flow System
...Show More Authors

A low-cost reverse flow plasma system powered by argon gas pumping was built using homemade materials in this paper. The length of the resulting arc change was directly proportional to the flow rate, while using the thermal camera to examine the thermal intensity distribution and demonstrating that it is concentrated in the centre, away from the walls at various flow rates, the resulting arc's spectra were also measured. The results show that as the gas flow rate increased, so did the ambient temperature. The results show that the medium containing the arc has a maximum temperature of 34.1 ˚C at a flow rate of 14 L/min and a minimum temperature of 22.6 ˚C at a flow rate of 6 L/min.

View Publication Preview PDF
Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Plasma Dynamics and Pulse Shape Rules in Laser Heating of Opaque Targets in Ai
...Show More Authors

A theoretical model is developed to determine time evolution of temperature at the surface of an opaque target placed in air for cases characterized by the formation of laser supported absorption waves (LSAW) plasmas. The model takes into account both plasma dynamics and time variation of incident laser pulse (i.e. pulse shape or profile).Shock tube relations were employed in formulating plasma dynamics over target surface. Gaussian function was chosen in formulating the pulse profile in the present modeling

View Publication Preview PDF
Publication Date
Mon Feb 25 2019
Journal Name
Iraqi Journal Of Physics
Influence of electrodes area ratios and the discharge volume in RF capacitively coupled plasma
...Show More Authors

Experimental results on harmonic distortions in 13.56 MHz RF Argon glow discharge using different grounded electrodes areas and electrodes spacing are presented. The experiment is carried out at four pressure values. RF power values used are between 20 and 90 watts. The results indicate significant increase in distortions at two specific values of the cone angle enclosing the two electrodes within its geometrical volume. The computation of the cone head angle gave the symmetry discharge or asymmetry as well as when the angle is small the condition is near symmetry discharge associated with decrease in the nonlinearity.

View Publication Preview PDF
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Cooling and Heating a Greenhouse in Baghdad by a Solar Assisted Desiccant System
...Show More Authors

Modeling the microclimate of a greenhouse located in Baghdad under its weather conditions to calculate the heating and cooling loads by computer simulation. Solar collectors with a V-corrugated absorber plate and an auxiliary heat source were used as a heating system. A rotary silica gel desiccant dehumidifier, a sensible heat exchanger, and an evaporative cooler were added to the collectors to form an open-cycle solar assisted desiccant cooling system. A dynamic model was adopted to predict the inside air and the soil surface temperatures of the greenhouse. These temperatures are used to predict the greenhouse heating and cooling loads through an energy balance method which takes into account the soil heat gain. This is not included in

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Iraqi Journal Of Physics
Study the Effect of Dielectric Barrier Discharge (DBD) Plasma on the Decomposition of Volatile Organic Compounds
...Show More Authors

Recently, research has focused on non-thermal plasma (NTP) technologies as a way to remove volatile organic compounds from the air stream, due to its distinctive qualities, which include a quick reaction at room temperature. In this work, the properties of the plasma generated by the dielectric barrier discharge (DBD) system and by a glass insulator were studied. Plasma was generated at different voltages (3, 4, 6, 7, 8 kV ) with a fixed distance between the electrodes of 5 mm, and a constant argon gas flow rate of (2.5) I/min. DBD plasma emission spectra were recorded for each voltage. The Boltzmann plot method was used to calculate the electron temperature in the plasma ( ), and the Stark expansion method was used to calculate the elec

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Plasma characteristics of Ag:Al alloy produced by fundamental and second harmonic frequencies of Nd:YAG laser
...Show More Authors

In this work, the spectra for plasma glow produced by pulse
Nd:YAG laser (λ=532 and 1064nm) on Ag:Al alloy with same molar
ratio samples in distilled water were analyzed by studying the atomic
lines compared with aluminum and silver strong standard lines. The
effect of laser energies of the range 300 to 800 mJ on spectral lines,
produced by laser ablation, were investigated using optical
spectroscopy. The electron temperature was found to be increased
from 1.698 to 1.899 eV, while the electron density decreased from
2.247×1015 to 5.08×1014 cm-3 with increasing laser energy from 300
to 800 mJ with wavelength of 1064 nm. The values of electron
temperature using second harmonic frequency are greater than of<

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Engineering
Optimization of Dye Removal Using Waste Natural Material and Polymer Particles
...Show More Authors

In this paper waste natural material (date seed) and polymer particles(UF) were used for investigation of  removal dye of the potassium permanganate. Also study effect some variables such as pH, dye concentration and adsorbent concentration on dye removal. 15 experimental runs were done using  the itemized conditions designed established on the Box-Wilson design employed to optimize dye removal. The optimum conditions for the dye removal were found: (pH) 12, (dye con.) 2.38 ppm, (adsorbant con.) 0.0816 gm for date seed with 95.22% removal and for UF (pH) 12, (dye con.) 18 ppm, (adsorbant con.) 0.2235 gm with 91.43%. The value of R-square was 85.47%  for Date seed  and (88.77%) for UF.

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 01 2016
Journal Name
Journal Of Engineering
Optimization of Hole Cleaning In Iraqi Directional Oil Wells
...Show More Authors

Efficient cuttings transport and hole cleaning are very important factors for obtaining an effective drilling operation. In an inclined and horizontal drilling, hole cleaning issue is a common and complex problem.

   The scope of this research is to study the drilling parameters which affect hole cleaning in Iraqi directional wells through studying and analyzing some drilled wells ( vertical , directional (30 degree) , directional (60 degree) and horizontal ).An excel sheet is prepared to calculate carrying capacity index which represents an indicator for good hole cleaning in different sections. The study indicated through the field investigations, practical experiences and theoretical calculations tha

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 01 2011
Journal Name
International Journal Of Mechanical And Materials Engineering
Simulation and design optimization of magneto rheological control valve
...Show More Authors

Magneto-rheological (MR) Valve is one of the devices generally used to control the speed of Hydraulic actuator using MR fluid. The performance of valve depends on the magnetic circuit design. Present study deals with a new design of MR valve. The finite element analysis is carried out on this valve to optimize its design. The design of the magnetic circuit is accomplished by magnetic finite element software such as Finite Element Method Magnetic (FEMM). The Model dimensions of MR valve, material properties and the circuit properties of valve coil are taken into account. The results of analysis are presented in terms of magnetic strength and magnetic flux density. The valve can be operated with variable flow rate by varying the current. It i

... Show More
View Publication Preview PDF
Scopus (2)
Scopus