This valve is intended for use in valves for steering movement, using the qualities of the Magneto-rheological (MR) fluid to regulate the fluid, direct contact without the utilization of moving parts like a spool, a connection between electric flux, and fluid power was made, The simulation was done to employ the" finite element method of magnetism (FEMM)" to arrive at the best design. This software is used for magnetic resonance valve finite element analysis. The valve's best performance was obtained by using a closed directional control valve in the normal state normally closed (NC) MR valve, with simulation results revealing the optimum magnetic flux density in the absence of a current and the shedding condition, as well as the optimum pressure. Finally, the MR valve proved successful in proportionally dominant in the direction and the quickness of the hydraulic actuators, and the new model allows hydraulic valves to be replaced with smaller valves while also lowering complexity.(Some of the figures in this article are only available in color in the online edition.)
There are different types of corruptions such as administrative, political, economic and financial corruption. The corruption forms also varied such as bribery, nepotism and extortion. All types and forms of corruption play significant role in the all economic variables generally and on investments in particular, and the corruption used to be an intermediate means in reducing the rate of economic growth. The corruption contributes in reducing the domestic investments via pay bribery by investors to officials’ persons for supplemental contracts and tenders which finally leads to reduction in the investment efficiency. The corruption also contributes in rise of operational costs for the investment projects. In additio
... Show MoreAbstract
Robotics manipulators with structural flexibility provide an attractive alternative to rigid robotics manipulators for many of the new and evolving applications in robotics. In certain applications their use is unavoidable. The increased complexity in modeling and control of such manipulators is offset by desirable performance enhancements in some respects. In this paperthe single- link flexible robotics manipulator was designed and implemented from Perspex and designed with 0.5 m length , 0.02 m width and with 0.004 m thickness with mass located at the tip. There are four subsystems; motion, control, accelerometer and gyro and a host computer subsystem. The work principle of single-link robotics manipul
... Show MoreThe aim of this paper is to construct the analysis mathematical model for stream cipher cryptosystems in order to be cryptanalysis using the cryptanalysis tools based on plaintext attack (or part from it) or ciphertext only attack, choosing Brüer generator as study case of nonlinear stream cipher system.
The constructing process includes constructing the linear (or non-linear) equations system of the attacked nonlinear generator. The attacking of stream cipher cryptosystem means solving the equations system and that means finding the initial key values for each combined LFSR.
Probit analysis is a type of regression used to analyze the relationship between a stimulus and the quantal response. Allelopathy refers to direct or indirect negative or positive effects of one plant on another through the release of chemical compounds into the environment. This study was carried out to apply probit analysis in investigating the allelopathic effects of the leaves aqueous extracts of apple of Sodom [Calotropis procera (Aiton) W.T.] on the inhibition of seed germination of African rattlebox (Crotalaria saltiana Andr.). A laboratory experiments were carried out at the Faculty of Agricultural Sciences, University of Gezira, Sudan in season 2014/15. Ten concentrations (2.3, 4.6
... Show MoreThe present work divided into two parts, first the experimental side which included the
measuring of the first natural frequency for the notched and unnotched cantilever composite beams
which consisted of four symmetrical layers and made of Kevlar- epoxy reinforced. A numerical
study covers the effect of notches on the natural frequencies of the same specimen used in the
experimental part. The mathematical model for the beam contains two open edges on the upper
surface. The effect of the location of cracks relative to the restricted end, depth of cracks, volume
fraction of fibers and orientation of the fiber on the natural frequencies are explored. The results
were calculated using the known engineering program (ANSY
The present study focused mainly on the analysis of stiffened and unstiffened composite laminated plates subjected to buckling load. Analytical, numerical and experimental analysis for different cases has been considered. The experimental investigation is to manufacture the laminates and to find mechanical properties of glass-polyester such as longitudinal, transverse young modulus, shear modulus. The compressive test was carried to find the critical buckling load of plate. The design parameters of the laminates such as aspect ratio, thickness ratio, boundary conditions and number of stiffeners were investigated using high order shear deformation theory (HOST) and Finite element coded by ANSYS .The main conclusion was the buckling load c
... Show MoreFourteen isolates were collected from a previous study and all were assigned to be Streptomyces genus, according to physiological and biochemical tests, however all the isolates varied morphologically and exhibited different antimicrobial activity. All 14 isolates were confirmed Streptomyces by 16S rRNA PCR amplification. Six isolates with high antimicrobial activities were ascertained Streptomyces spp. by sequencing and phylogenetic analysis. Two isolates among the selected 6 isolates with antimicrobial activity against E. coli and S. aureus . It recommended to make a complete sequence for 16S rRNA to detect the species that
... Show MoreJoint diseases, such as osteoarthritis, induce pain and loss of mobility to millions of people around the world. Current clinical methods for the diagnosis of osteoarthritis include X-ray, magnetic resonance imaging, and arthroscopy. These methods may be insensitive to the earliest signs of osteoarthritis. This study investigates a new procedure that was developed and validated numerically for use in the evaluation of cartilage quality. This finite element model of the human articular cartilage could be helpful in providing insight into mechanisms of injury, effects of treatment, and the role of mechanical factors in degenerative
conditions, this three-dimensional finite element model is a useful tool for understanding of the stress d