Crude oil is one of the most important sources of energy in the world. To extract its multiple components, we need oil refineries. Refineries consist of multiple parts, including heat exchangers, furnaces, and others. It is known that one of the initial operations in the refineries is the process of gradually raising the temperature of crude oil to 370 degrees centigrade or higher. Hence, in this investigation the focus is on the furnaces and the corrosion in their tubes. The investigation was accomplished by reading the thickness of the tubes for the period from 2008 to 2020 with a test in every two year, had passed from their introduction into the work. Where the thickness of more than one point was measured on each tube in the same row and the corrosion rate was extracted for three furnaces, starting from the area of heat transfer by radiation to the heat transfer area of the convection in three different operating units. It was found that the highest percentage corrosion value between the standard tube thickness and the thickness of conduction position was 37% with the conduction zone, and 31% with radiation zone. There, the tubes specification was tested. Five percent Cr-0.5 Moly and the temperature of radiation zone was 578 °C to 613 °C and the stack temperature was 410 °C to 450 °C. So, the results show that the maximum erosion occur at the convection zone.
The inhibition ability of the new derivative (quinolin-2-one), namely (1-{[5-(2-Chloro-phenylazo)-2- hydroy-benzylidene]-amino}-4,7-dimethyl -6-nitro- 1H-quinolin-2-one (CPHAQ2O)) towards carbon steel corrosion in (3.5% NaCl) and (0.5M HCl) solutions were evaluated by potentiodynamic polarization at different inhibitor concentrations. Polarization curves showed that the evaluated compound acted as mixed inhibitors, and the adsorption of the evaluated inhibitor obeys the Langmuir adsorption isotherm in both salt and acid solutions. The results revealed that the percentage inhibition efficiency (%IE) in the salty solution (90.55%) is greater than that in the acidic solution (77.62%). The surface changes of the carbon steel and the film per
... Show MoreThis study was prepared to investigate the performance and behavior of concrete thrust blocks supporting pipe fittings. In the water distribution networks, it is always necessary to change the path of the pipes at different degrees or to create new branches. In these regions, an unbalanced force called the thrust force is generated. In order to counter this force, these regions are supported with concrete blocks. In this article, the system components (soil, pipe with its bend and thrust blocks) have been numerically modeled and simulated by the ABAQUS CAE/2019 software program in order to study the behavior and stability of the thrust block with different burial conditions (several b
This paper contains studying of the Evaluation for the Petrophysical Properties of
Yamama Formation in Ratawi Field which occurs in about 70 km to the west of
Basrah city in Mesopotamia zone (Zubair subzone). The study includes a
petrophysical evaluation and (3 Dimensions) geological model for each unit
especially the three hydrocarbon units comprising the Yamama Formation in (5)
boreholes which are Rt-3, Rt-4, Rt-5, Rt-6 and Rt-7 distributed on the crest and
flanks of the Ratawi structure that are carried out in the present study. The
formation's boundaries were determined using well logs, available core intervals and
by Petrophysical data and it is found that it can be subdivided into three main
reservoir uni
The electrochemical behavior of carbon steel in water sweetening station in Libya has been studied in the range of ( 293–333 oC) using weight loss technique. Measurements were carried out over a range of Reynolds number (5000 – 25000).An apparatus was designed for studying the corrosion process in the turbulent regime, which is of industrial significance. It was found that The corrosion rate of carbon steel in water sweetening station is under diffusion control and increases with increasing Reynolds number. On the other hand the variation of corrosion rate with temperature in the range of (293–333 oC) was found to follow Arrhenius equation and the activation energy approximately the same except at low Reynolds
... Show MoreAbstract
The research dealt with a studying the impact of oil price fluctuations on one of the rules of financial discipline, which is the rule of budget deficit in the Iraqi economy for the period (2003-2020) as it is one of the quarterly economies that rely mainly on volatile oil revenues that fluctuate with oil prices in global markets, and therefore the general budget suffers. from The state of instability and then the government resorts to borrowing for a long time . this deficit in the general budget and increase the debt burden in the public debt.The research aim to measure and study the impact of oil price flu
... Show MoreThe fluctuations in oil prices in world markets affect the general budget and the trade balance of the rent countries, because oil is a strategic commodity affected by economic and political factors. The fluctuations in oil prices affect the public budgets of the rent countries through the public revenue side of oil revenues. On the other hand, these fluctuations affect the balance of trade through the volume of oil exports, which lead to imbalance of trade surplus or deficit . &nbs
... Show MoreA total of 50 wells water samples were collected from 10 wells in Abu Ghraib site/ Baghdad for detection of coliform, fecal coliformand and pseudomonas aeruginosa bacteria, and the pollution of toxic ions (No3-, B+3, pb+2 and Cd+2 ) in wells water. Results showed microbial pollution by coliform, fecal Coliform bacteria in wells water when using presumptive, confirmed and complete tests, P. aeruginosa bacterium was isolated and identificated on Cetrimide Agar media, estimated the Most Probable Number (MPN) of coliforms and P. aeruginosa, results showed difference in mean of (MPN) of wells water. Most of toxic ions concentrations were low comparing with the recommended hygienic standards from the World Health Organization (WHO). Wells wate
... Show MoreAn experimental study is conducted to investigate the effect of heat flux distribution on the boiling safety factor of its cooling channel. The water is allowed to flow in a horizontal circular pipe whose outlet surface is subjected to different heat flux profiles. Four types of heat flux distribution profiles are used during experiments: (constant distribution profile, type a, triangle distribution profile with its maximum in channel center, type b, triangle distribution profile with its maximum in the channel inlet, type c, and triangle distribution profile with its maximum in the channel outlet, type d). The study is conducted using heat sources of (1000 and 2665W), water flow rates of (5, 7 and 9 lit/min). The water
... Show More