Preferred Language
Articles
/
5xcn-44BVTCNdQwC4lp_
Rapid colorimetric sensing of chlorpromazine HCl antipsychotic through <i>in situ</i> growth of gold nanoparticles
...Show More Authors

This assay rapidly detects chlorpromazine hydrochloride using its ability to reduce gold ions to form nanoparticles. Its low cost, resilience to interferences and short analysis time could facilitate environmental monitoring and biomedical analysis.

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Global Pharma Technology
Serum levels of cross-linked n-telopeptide of Type i collagen before and after non-surgical periodontal therapy in type 2 diabetic patients with chronic periodontitis
...Show More Authors

Background: Diabetes mellitus is a major risk factor for chronic periodontitis (CP) and hyperglycemia has an important role in the enhancement of the severity of the periodontitis. It has been reported that the progression of CP causes shifting of the balance between bone formation and resorption toward osteoclastic resorption, and this will lead to the release of collagenous bone breakdown products into the local tissues and the systemic circulation. Cross-linked N-telopeptide of type I collagen (NTx) is the amino-terminal peptides of type I collagen which is released during the process of bone resorption. This study was conducted to determine the effects of nonsurgical periodontal therapy on serum level of NTx in type 2 diabetic patients

... Show More
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine And Public Health
SPECTROPHOTOMETRIC DETERMINATION OF DIPHENHYDRAMINE HCL IN PURE AND PHARMACEUTICAL FORMULATIONS USING THYMOL BLUE
...Show More Authors

This approach was developed to achieve an accurate, fast, economic and sensitivity to estimation of diphenhydramine Hydrochloride. The dye that produced via reaction between diphenhydramine HCl with thymol blue in acidic medium pH ≈ 4.0. The ion pair method include an optimization study to formed yellowcolored that extraction by liquid – liquid method. The product separated of complexes by using by chloroform solution measured spectrophotometry at 400 nm. The analysis data at optimum conditions showed that linearity concentration in a range of calibration curve 1.0 – 50 μg /mL, limit of detectionand limit of quantification 0.0786 and 0.2358 μg/mL respectively. The molar absorptivity and Sandell’s sensitivity were 1.8 × 10 -4 L/mo

... Show More
View Publication
Crossref
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effect of In-situ Stress on Hydraulic Fractures Dimensions
...Show More Authors

Understanding of in-situ stress profiles and orientations plays a vital role in designing a successful hydraulic fracturing treatment. This paper is an attempet to examine the effect of lithology and in situ stress on geometery of hydraulic fractures. A hydraulic fracturing design simulator software called FracproPT with various capabilities for designing most of hydraulic fracture was used for  simulate and optimize the hydraulic fracturing. For studying purpose,  three different cases of stress gradient contrast between different formations  are considered in this study (0.4, 0.5 and 0.75 psi/ft). The results obtained from the simulator showed that  lithologies surrounding the pay zone have an effect on the fracture

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
EX-SITU Characterization of Luffa aegyptaica in Lagos State, Nigeria
...Show More Authors

Luffa aegyptiaca is a plant of multi-purpose importance whose usefulness cuts across virtually all areas of life. This study has characterized L. aegyptiaca in Lagos state and determined the mineral, proximate, phytochemical as well as the heavy metal accumulation potential. Samples were collected from the 20 Local Government Areas (LGAs) in Lagos state at 2 samples per location.   Genetic similarity and intra-specific variation in 40 samples of L. aegyptiaca were determined using 3 Random Amplified Polymorphic DNA (RAPD) primers which yielded a total of 42 markers of which 25 was polymorphic. The maximum number of bands (14) was produced by OPC4 while the minimum (7) were produced by OPAF20. Percenta

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Jan 21 2018
Journal Name
Drug Invention Today
Preparation and evaluation of lornoxicam in situ gelling liquid suppository
...Show More Authors

Preview PDF
Scopus (5)
Scopus
Publication Date
Sat Jan 17 2009
Journal Name
مجلة تكريت للعلوم الصرفة
دراسة الصفات الحركية لمتناظرات أنزيم الالنين امينو ببتيديزAAP II,I في ادرار المرضى المصابين بالعجز الكلوي المزمن.مجلة تكريت للعلوم
...Show More Authors

Publication Date
Mon Feb 24 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The relationship among bite force with facial dimensions and dental arches widths in a sample of Iraqi adults with Class I skeletal and dental relations
...Show More Authors

Background: This study aimed to determine whether there is a relationship among the bite force with facial dimensions and dental arches in a sample of Iraqi adults with Class I skeletal and dental relations. Materials and methods: Forty dental students (20 males and 20 females) were selected under certain criteria. For those individuals, dental impressions, frontal facial photographs and maximum bite force at molar and incisor regions were taken. The dental arches widths and facial dimensions were measured using the AutoCAD program 2007, while the bite force was determined using special device. Descriptive statistics for the measured variables were performed and gender difference was determined using independent sample t-test, while the rel

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 18 2019
Journal Name
Iraqi Journal Of Science
Simple Colorimetric Method Using Aqueous Solution to Detect Heavy Metal
...Show More Authors

Simple method has been used to determine the absence of heavy metals in an aqueous solution. Fluorescein was used as the base colorimetric materialThis was doped with CuCl2 and the final solution showeda clear change in color. This change was correlated with the change in both pH and electrical conductivity of the solution. The optical property as an obvious change of the spectra was observed. Therefore, this simple method could be proposed as a method to detectheavy metals in any solution.

View Publication Preview PDF
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Colorimetric Determination of Salbutamol Sulfate using Spectrophotometry-Continuous Flow Injection Technique in Pure and Pharmaceutical Forms
...Show More Authors

Simple, precise and economic batch and flow injection analysis (FIA)-spectrophotometric methods have been established for simultaneous determination of salbutamol sulfate (SLB) in bulk powder and pharmaceutical forms. Both methods based on diazotization coupling reaction of SLB with another drug compound (sulfadimidine) as a safe and green diazotization agent in alkaline medium. At 444 nm, the maximum absorption of the orange azo-dye product was observed. A thorough investigation of all chemical and physical factors was conducted for batch and FIA procedures to achieve high sensitivity. Under the optimized experimental variables, SLB obeys Beer’s law in the concentration range of 0.25-4 and 10-100 μg/mL with limits of detection of 0.0

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Colorimetric Determination of Salbutamol Sulfate using Spectrophotometry-Continuous Flow Injection Technique in Pure and Pharmaceutical Forms
...Show More Authors

Simple, precise and economic batch and flow injection analysis (FIA)-spectrophotometric methods have been established for simultaneous determination of salbutamol sulfate (SLB) in bulk powder and pharmaceutical forms. Both methods based on diazotization coupling reaction of SLB with another drug compound (sulfadimidine) as a safe and green diazotization agent in alkaline medium. At 444 nm, the maximum absorption of the orange azo-dye product was observed. A thorough investigation of all chemical and physical factors was conducted for batch and FIA procedures to achieve high sensitivity. Under the optimized experimental variables, SLB obeys Beer’s law in the concentration range of 0.25-4 and 10-100 μg/mL with limits of detection o

... Show More
Scopus (4)
Crossref (2)
Scopus Crossref