Objective: The purpose of this work was to develop and optimize the emulgel formulation of piroxicam with two types of gelling agent chitosan and xanthan gum. The release profiles of prepared formulas were investigated. In addition, the rheology and stability of the best formula were investigated.Methods: Emulsified piroxicam was prepared to use oleic acid, tween 80 and PG with a ratio (3:10:10). In xanthan based emulgel, the xanthan gum (1% and 1.5%) was spread as powder on emulsified piroxicam with stirring until emulgel was formed. In chitosan-based emgels, Chitosan gel was added to emulsified piroxicam and stirring until the Emulgel was constructed. Chitosan gels were prepared by incorporating different concentration, 2%, 3%, 6% w/v of chitosan in 1% v/v of glacial acetic acid in distilled water. In vitro release of piroxicam from different formulas was conducted in 300 ml phosphate buffer pH 7.4, at a speed of 120 rpm at 37±2°C. The amount of the drug released from the bases was determined spectrophotometrically at 504 nm. Viscometer Myr. Vr 3000 was used to measure the viscosity of the prepared formulas. The prepared formulas were stored in well-stoppered polyvinyl chloride (PVC) plastic containers in the dark for 6 mo at room temperature. They were checked for drug content, viscosity, and pH change bimonthly throughout the period.Results: The results showed that the dissolution increases significantly with increasing the concentration of xanthan. Chitosan has significant synergized the enhancements of xanthan gum in the release. Rheological behaviour of the selected formula containing chitosan (2%) and xanthan gum (1.5) had shear thinning in nature showing a decrease in viscosity at the increasing shear rates. The selected formula was stable 6 mo at 40˚C/75% RH and 4˚C. The formula found was yellow viscous creamy preparation with the smooth homogenous appearance. The pH and the drug release was also found to be stable under storage conditions.Conclusion: Piroxicam release can be improved by preparing emulgel which stable and have good rheologic properties.
Background: The materials and techniques of orthodontic bonding systems remain a pivotal concern in orthodontic research. This issue is further complicated by orthodontists' preferences. To assess the effect of knowledge and practice on the attitudes of orthodontists towards bonding materials and techniques. Methods: A cross-sectional, questionnaire-based study was conducted using Google Forms. The questionnaire comprised 17 multiple-choice questions that targeted orthodontists' awareness, knowledge, and attitude towards bonding materials. It was distributed via email or social networking platforms to specialist Iraqi orthodontists. Results: A total of 176 participants responded with nearly equal representation between the sexes. Th
... Show MoreRainfall in Nigeria is highly dynamic and variable on a temporal and spatial scale. This has taken a more pronounced dimension due to climate change. In this study, Standard Precipitation Index (SPI) and Mann-Kendall test statistical tools were employed to analyze rainfall trends and patterns in Gombe metropolis between 1990 and 2020 and the ARIMA model was used for making the forecast for ten (10) years. Daily rainfall data of 31 years obtained from Nigerian Meteorological Agency, (NIMET) was used for the study. The daily rainfall data was subjected to several analyses. Standard precipitation index showed that alternation of wet and dry period conditions had been witnessed in the study area. The result obtained showed that there is an u
... Show MoreSelf-compacting concrete (SCC) has undergone a remarkable evolution recently based on the results from several studies that have indicated the chain of benefits SCC provides. Micro and nano materials used as mineral additives in SCC offer several high-performance properties, and this research studies the effects of micro silica (MS) (10%, used as a reference) and colloidal nano-silica (CNS) (2.5%, 5%, 7.5%, and 10%) on the fresh and hardened properties of SCC. All mixtures were estimated using flow, L-box, and V-funnel tests to examine workability and compressive strength, modulus of elasticity and tensile strength as hardened properties. The use of CNS increased the overall compressi
To detect the amount of rifampicin in bulk and medicinal dosage formulations, an accurate and costeffective UV spectrophotometric technique has been developed using the area under the peak to estimate the presence of rifampicin. This range of wavelengths (300–356 nm) was chosen. The method showed linearity in the 2–22 μg/mL range, with R2 being2 0.9996. The developed method’s linearity, detection limit, quantification limit, precision, repeatability, and accuracy were all statistically and experimentally validated. The suggested methodology can be used for routine quality control analysis of rifampicin in pure form and in capsule dosage form, as demonstrated by the satisfactory recovery percentage results. This study explores the str
... Show MoreTo detect the amount of Rifampicin in bulk and medicinal dosage formulations, an accurate, and cost-effective UV spectrophotometric technique has been developed using the area under the peak to estimate the presence of Rifampicin. This range of wavelengths (300–356) nm was chosen. The method showed linearity in the 2-22 μg/mL range, with R2 being 0.9996. The developed method' linearity, detection limit, quantification limit, precision, repeatability, and accuracy were all statistically and experimentally validated. The suggested methodology can be used for routine quality control analysis of Rifampicin in pure form and in capsule dosage form, as demonstrated by the satisfactory recovery percentage results. This study explores the struct
... Show More