Mefenamic acid belongs to non-steroidal anti-inflammatory drugs that are used widely for the treatment of analgesia. Our aim from this study is to establish a new assay for the quantitative determination of mefenamic acid (MFA) in the pharmaceutical sample by two sensitive and rapid flow injection-fluorometric methods. A homemade fluorometer was used in fluorescence measurements, which using solid-state laser diode 405 and 532 nm as a source, combined with a continuous flow injection technique. The first method depends on the effect of MFA on calcein blue (CLB) fluorescence at 405 nm. Another method is a study of rhodamine-6G (Rh-6G) fluorescence after adding MFA, and recording at 532 nm. Optimum parameters as fluorescent dye concentration, basic medium, flow rate, sample volume, purge time, and delay coil have been investigated. The dynamic range of MFA was 0.2 to 2 mmol.L-1; 0.5 to 2.3 mmol.L-1 with linearity percentage (% r2) 98.92 and 99.83%, for Rh-6G and CLB, respectively. Limit of detection at a minimum concentration in calibration curve 189.34 and 199.89 ng/sample, for Rh-6G and CLB, respectively. The comparison of developed methods with the classical method (UV-vis spectrophotometry) was achieved. The proposed methods were successfully applied for the determination of MFA in the pharmaceutical samples and can be used as an alternative method.
In this research, the results of x-ray diffraction method were used to determine the uniform stress deformation and microstructure parameters of CuO nanoparticles to determine the lattice strain obtained and crystallite size and then to compare the results obtained by two model Halder Wagner and Size Strain Plot with the results of these methods of the same powder using equations during which the calculation of the size of the crystallite size and lattice strain, It was found that the results obtained the values of the crystallite size (19.81nm) and the lattice strain (0.004065) of the Halder-wagner model respectively and for the ssp method were the results of the crystallite size (17.20nm) and lattice strain (0.000305) respectively. The sa
... Show MoreA sensitive and accurate colorimetric method was developed for the determination of the Sitagliptin phosphate monohydrate, here and after will be named Sitagliptin, in its pure and pharmaceutical form. The suggested approach is based on boosting the sensitivity of the traditional spectrometric methods by derivatizing Sitagliptin into a colored product that absorbs the visible spectrum at 573 nm. The proposed method has effectively improved the sensitivity and the limit of detection for the analysis of Sitagliptin. A linear calibration curve was obtained over the concentration range of 0.1-10 μg/ml with a correlation coefficient of 0.9983. The calculated recovery was within the range of 98.98–100.11%. While the limit of detection LOD and
... Show MoreBackground: We aimed to investigate the accuracy of salivary matrix metalloproteinases (MMP)-8 and -9, and tissue inhibitor of metalloproteinase (TIMP)-1 in diagnosing periodontitis and in distinguishing periodontitis stages (S)1 to S3. Methods: This study was a case–control study that included patients with periodontitis S1 to S3 and subjects with healthy periodontia (controls). Saliva was collected, and then, clinical parameters were recorded, including plaque index, bleeding on probing, probing pocket depth, and clinical attachment level. Diagnosis was confirmed by assessing the alveolar bone level using radiography. Salivary biomarkers were assayed using an enzyme-linked immunosorbent assay. Results: A total of 45 patients (15
... Show MoreTo evaluate the effects of the ShotBlocker and vibration device on pain intensity and patient satisfaction during subcutaneous (SC) insulin injections in hospitalized adults with type 2 diabetes mellitus.
In this randomized controlled trial, 102 patients with type II diabetes mellitus were randomly assigned into 3 groups: 35 patients in the ShotBlocker group, 36 patients in the vibration group, and 31 patients in the control group. ShotBlocker was applied immediately before and during the injection, while the vibration was applied fo
Thyroid hormones, triiodothyronine (T3) and thyroxin (T4) play an important role in growth, development, and physiology of the kidney. The kidney has a central role in metabolism and clearance of these hormones as well as thyroid – stimulating hormone (TSH). Chronic renal failure (CRF) is a state of irreversible deceleration in renal function results in alterations in internal milieu, which affects the synthesis and secretory rate of hormones. To evaluate the thyroid hormone levels in non-dialyzed patients with chronic renal failure (CRF); 24 patients with CRF aged 30-70 years, mean±S.d. (48.458 ± 13.569) and 48 healthy volunteers who served as controls aged 30-70 years (43.104 ± 12.387) were studied for their thyroid function status u
... Show MoreA new simultaneous spectrophotometric-kinetic method was developed to determine phenylephrine (PHEN) and tetracycline (TETR) via H-point standard addition method (HPSAM). The proposed procedures rely on the measurements of the difference in the rate of charge-transfer (CT) reaction between each of PHEN and TETR as electron donors with p-Bromanil (p-Br) as an electron acceptor. Different experimental factors which affect the extent of the complex formation were investigated by monitoring the value of absorbance at 446 nm. Time pair of 50 -100 sec was selected and employed, among different examined pairs since it results in the highest accuracy for HPSAM-plot. Linear calibration graphs in the concentration ranges of 10.0-40.0 and 10.0–50.0
... Show MoreBackground: The cells of periodontium contain many intracellular enzymes like (alkaline phosphatase ALP) that are released outside into the saliva and gingival crevicular fluid (GCF) after destruction of periodontal tissue. The aim of study was to determine the activity of this enzyme in saliva and its relation to the salivary flow rate, PH and clinical periodontal parameters in patients with chronic periodontitis. Subject, Materials and methods: Sample population consist of 75 individuals ;divided into four groups , the first group (15):control subject, the second group (20):mild chronic periodontitis, the third group(20) moderate chronic periodontitis and the fourth group (20) sever chronic periodontitis, Measurements of plaque index (PL
... Show More