Preferred Language
Articles
/
4xaBaIgBVTCNdQwCp3aI
Clinical and Refractive Outcomes of Toric Phakic Implantable Collamer Lens Implantation for correction of myopic astigmatism
...Show More Authors

Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber. Aim: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. Methods: Sixty eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design) in the Eye Specialty Private Hospital, Baghdad, Iraq were studied. The mean spherical refraction was -11.32±3.17 diopter (D) with a range of -6.00 to -18.00 D and a mean cylinder of -2.61±1.16 with range of -1.00 to -5.50 D. The outcome measures that evaluated during a 12 months follow-up period include UDVA, refractive outcomes, CDVA, vault and adverse events. Results: At 12 months postoperatively, the mean Snellen decimal UDVA was 0.77±0.23 and the mean CDVA was 0.80±0.21, with an efficacy index of 1.16. Twenty nine eyes (48.33%) showed gain in CDVA with a safety index of 1.21. The treatment was highly predictable for spherical equivalent and astigmatic component. The mean SE dropped from -12.63±3.11 D to -0.11±0.20 D with 58 eyes within ±0.50 D and 60 eyes with ±1.00 D of the target correction. For achieved cylinder 60 eyes (100%) had ≤0.50 D and 51 eyes (85%) had ≤0.25 D with a strong positive linear correlation between achieved and expected cylinder (r=0.94). Conclusion: The results of the present study support safety, efficacy, predictability of toric implantable collamer lens implantation to treat moderate to high myopic astigmatism Abbreviation: UDVA: uncorrected distance visual acuity, CDVA: corrected distance visual acuity, SE: spherical equivalent and ACD: anterior chamber depth

Crossref
View Publication
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Oral Medicine And Oral Surgery
Evaluating dental implant stability using three devices Osstell<sup>®</sup>, Periotest<sup>®</sup>, and AnyCheck<sup>®</sup>: a clinical study
...Show More Authors

Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®) to assess the correlations of the measurements obtained by these devices and the correlations between implant stability and insertion torque. Material and Methods: This observational prospective study included 35 dental implants. The implant stability was measured using the 3 devices. Mann–Whitney U

... Show More
View Publication
Crossref
Publication Date
Thu Aug 29 2024
Journal Name
European Journal Of Orthodontics
Poly-ether-ether-ketone (PEEK) versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 1. Stability, retainer failure, and participant satisfaction
...Show More Authors
Abstract<sec> <title>Background

Poly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys.

Objective

To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC).

Trial design

A single-centre, two-arm parallel groups

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Preparation and identification of oxidatin derivaties for Salts and acids of bile for medical uses
...Show More Authors

The purified prepared compounds were identified through different methods of identification i.e, I.R, UV-vi^ble-spectroscopy in addition to (coloured tests) Calculation of the sum of OH groups. TLC techniques were also used to test the purity and the speed ofthe rate of flow (RF).

View Publication Preview PDF
Publication Date
Mon May 01 2023
Journal Name
3 Biotech
Detection of orthodontically induced inflammatory root resorption-associated biomarkers from the gingival crevicular fluid by proteomics analysis: a randomized-controlled clinical trial
...Show More Authors

View Publication
Crossref (3)
Crossref
Publication Date
Wed Mar 28 2018
Journal Name
Iraqi Journal Of Science
Bacteriocin from Streptococcus salivarius optimized statistically by response surface methodology active against different clinical oral pathogenic Streptococci
...Show More Authors

The aim of the present work was to study the possibility of producing an effective bacteriocin from bacteria naturally exists in the mouth. Streptococcus salivarius KA101 was selected among 120 oral isolates collected from healthy people based on its ability to produce an effective bactericidal bacteriocin. Modified tryptic soy agar with 2% yeast extract and 0.1% calcium carbonate was the best medium for the production of bacteriocin with an activity of 40 AU/ml. Response surface methodology (RSM) based on central composite design (CCD) was employed to build a model in order to evaluate the optimum effective factors for bacteriocin production using four factors: yeast extract, CaCO3, pH and incubation time. Based on t

... Show More
View Publication Preview PDF
Publication Date
Thu Aug 15 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
The Impact of the Chlorhexidine Gel (WISDOM®) on Postoperative Sequelae Associated with the Surgical Removal of Impacted Mandibular Third Molars: A Randomized Controlled Clinical Trial
...Show More Authors

Background: One of the most prevalent procedures in oral surgery is the removal of impacted mandibular third molars, typically accompanied by trismus, edema, and pain. Several methods and biomaterials were implemented to mitigate or avoid these surgical problems. Objectives: To evaluate the efficiency of chlorhexidine gel (WISDOM®) in minimizing postoperative sequelae associated with the impacted mandibular third molar that will be surgically extracted and its role in promoting early soft tissue closure of the surgical site. Methods: The study design was a double-masked and randomized, controlled clinical study that included healthy patients needing the removal of a mandibular third molar through surgery. The participants were rand

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Dec 01 2021
Journal Name
International Journal Bioautomation
Model for Prediction of the Weight and Height Measurements of Patients with Disabilities for Diagnosis and Therapy
...Show More Authors

Background: Accurate measurement of a patient’s height and weight is an essential part of diagnosis and therapy, but there is some controversy as to how to calculate the height and weight of patients with disabilities. Objective: This study aims to use anthropometric measurements (arm span, length of leg, chest circumference, and waist circumference) to find a model (alternatives) that can allow the calculation of the height and the body weight of patients with disabilities. Additionally, a model for the prediction of weight and height measurements of patients with disabilities was established. Method: Four hander patients aged 20-80 years were enrolled in this study and divided into two groups, 210 (52.5%) male and 190 (47.5%) fe

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Fri Sep 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Reliability of the multipeg™ transducer in measuring dental implant stability by using a resonance frequency analysis device (Osstell®): An observational clinical study
...Show More Authors

Background: Measuring implant stability is an important issue in predicting treatment success. Dental implant stability is usually measured through resonance frequency analysis (RFA). Osstell® RFA devices can be used with transducers (Smartpeg™) that correspond to the implants used as well as with transducers designed for application with Penguin® RFA devices (Multipeg™). Aims: This study aims to assess the reliability of a MultiPeg™ transducer with an Osstell® device in measuring dental implant stability. Materials and Methods: Sixteen healthy participants who required dental implant treatment were enrolled in this study. Implant stability was measured by using an Osstell® device with two transducers, namely, Smartpeg™ and M

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
The Attitudees toward aggresive behaviore for sample of college of education and college of science for womens student: The Attitudees toward aggresive behaviore for sample of college of education and college of science for womens student
...Show More Authors

Abstract
The purposes of this study were to identifying the (attitudes of college of
education and college of science for womens in Baghdad university students
toward aggresive behaviore) and to determine the differences of student's
attitudes due to Specialization.
The study sample consists of (460) Female students.Aquestionave of
(59) items was desiged and distributed selected sample after established it's
validity and reliablity.The results indicated that the attitude of Baghdad
University For College of education and college of science students toward
aggresive behaviore were Negative.
The findings revealed that there were statistically significant differences
in the student's attitudes due to special

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 30 2019
Journal Name
Journal Of The College Of Education For Women
Social and psychological problems for students of the faculties of Engineering and Education for Girls in Baghdad University
...Show More Authors

The subject of youth care of important issues in view of what constitutes the importance
to the development of societies in general and as much as enjoy young people in any society
are good psychological health and agree psychosocial be healthy to be effective to invest their
energies and their potential for the progress of that society and development of the social
aspects and economic. The universities of the most important educational institutions that
provide care for young people, they are as well as providing information and expertise
necessary to prepare young people for life and the development of mental abilities, they are
different activities that will satisfy their needs physical, psychological, social and

... Show More
View Publication Preview PDF