Preferred Language
Articles
/
4xaBaIgBVTCNdQwCp3aI
Clinical and Refractive Outcomes of Toric Phakic Implantable Collamer Lens Implantation for correction of myopic astigmatism
...Show More Authors

Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber. Aim: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. Methods: Sixty eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design) in the Eye Specialty Private Hospital, Baghdad, Iraq were studied. The mean spherical refraction was -11.32±3.17 diopter (D) with a range of -6.00 to -18.00 D and a mean cylinder of -2.61±1.16 with range of -1.00 to -5.50 D. The outcome measures that evaluated during a 12 months follow-up period include UDVA, refractive outcomes, CDVA, vault and adverse events. Results: At 12 months postoperatively, the mean Snellen decimal UDVA was 0.77±0.23 and the mean CDVA was 0.80±0.21, with an efficacy index of 1.16. Twenty nine eyes (48.33%) showed gain in CDVA with a safety index of 1.21. The treatment was highly predictable for spherical equivalent and astigmatic component. The mean SE dropped from -12.63±3.11 D to -0.11±0.20 D with 58 eyes within ±0.50 D and 60 eyes with ±1.00 D of the target correction. For achieved cylinder 60 eyes (100%) had ≤0.50 D and 51 eyes (85%) had ≤0.25 D with a strong positive linear correlation between achieved and expected cylinder (r=0.94). Conclusion: The results of the present study support safety, efficacy, predictability of toric implantable collamer lens implantation to treat moderate to high myopic astigmatism Abbreviation: UDVA: uncorrected distance visual acuity, CDVA: corrected distance visual acuity, SE: spherical equivalent and ACD: anterior chamber depth

Crossref
View Publication
Publication Date
Fri Jan 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Radiographic follow up for clinical cases of mandibular implant retained overdenture MIR-OD
...Show More Authors

Background: The use of osseointegrated fixtures in dentistry has been demonstrated both histologically and clinically to be beneficial in providing long term oral rehabilitation in completely edentulous individual. Most patients suffer from denture instability; particularly with mandibular prosthesis, the use of dental implant will be benefit significantly from even a slight increase in retention. The concept of implanting two to four fixtures in a bony ridge to retain a complete denture prosthesis appealing therefore, as retention, stability and acceptable economic compromise to the expanse incurred with the multiple fixture supported fixed prosthesis. Materials and methods in this study the sample were eight patients selected from a hosp

... Show More
View Publication Preview PDF
Publication Date
Mon May 29 2023
Journal Name
Rawal Medical Journal
Comparison of functional and radiological outcomes of lower third closed tibia fractures treated by nail VS plate osteosynthesis
...Show More Authors

Objective: To determine the functional and radiological outcomes of lower third tibia closed fractures fixed by nail or plate osteosynthesis. Methodology: This randomized controlled trial included 20 patients presenting with closed fracture lower third tibia in Al-Kindy teaching hospital, Baghdad, Iraq. The patients were divided as every other one into two equal groups; group I had fractures fixed by 3.5 mm locked plate and group II by intramedullary locking nail. We followed all patients for 24 weeks to assess surgical complications, fracture union, alignment and functional outcome based on Knee society score (KSS). Results: The mean union time in both groups was 10.2 ± 1.48 and 9.3 ± 1.77 weeks, respectively (p = 0.003). Mean KSS in bot

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Jul 21 2014
Journal Name
Sensors
Reduction of the Dimensionality of the EEG Channels during Scoliosis Correction Surgeries Using a Wavelet Decomposition Technique
...Show More Authors

This paper presents a comparison between the electroencephalogram (EEG) channels during scoliosis correction surgeries. Surgeons use many hand tools and electronic devices that directly affect the EEG channels. These noises do not affect the EEG channels uniformly. This research provides a complete system to find the least affected channel by the noise. The presented system consists of five stages: filtering, wavelet decomposing (Level 4), processing the signal bands using four different criteria (mean, energy, entropy and standard deviation), finding the useful channel according to the criteria’s value and, finally, generating a combinational signal from Channels 1 and 2. Experimentally, two channels of EEG data were recorded fro

... Show More
View Publication
Scopus (13)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Sun Dec 30 2012
Journal Name
Al-kindy College Medical Journal
A typical clinical presentation of molluscum contagiosum in Iraqi patients;clinical descriptive study
...Show More Authors

Background Molluscum contagiosum is skin disease caused by the molluscum contagiosum virus (MCV) usually causing one or more small dome shaped umbilicated papules with symptoms that maybe self-resolve. MCV was once a disease primarily of children, but it has evolved to become a sexually transmitted disease in adults. It is believed to be a member of the pox virus family. In addition to the classic presentation of the disease; it can also come in different clinical forms that simulate large number of dermatolological disease.
Objective: To study different clinical forms of Molluscum contagiosum presentation in different age groups of Iraqi patients.
Method:This clinical descriptive study was performed in the outpatient department of

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2022
Journal Name
The Egyptian Journal Of Hospital Medicine
The Impact of rs767455 and rs1061622 Polymorphisms ‎on ‎Treatment Outcomes in Iraqi Ankylosing Spondylitis ‎Patients Taking ‎Etanercept
...Show More Authors

Background: Ankylosing spondylitis (AS) is inflammation of the sacroiliac joints and spine, associated with clinical symptoms such as pain and stiffness in the vertebral column, after which, in a considerable number of individuals, new bone growth occurs. Objective: The current research study attempted to find out whether the presence of SNPs in TNF receptor [TNFRSF1A (rs767455), TNFRSF1B (rs1061622)] encoding genes could influence patients' outcomes to etanercept in a specimen of Iraqi AS patients. Patients and methods: Sixty patients with established AS receiving only etanercept were selected to be enrolled in this research with a mean age of 40.75 ± 8.67 years, 51 patients of them were males and only 9 patients were females. Patients we

... Show More
Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Aug 30 2023
Journal Name
Al-kindy College Medical Journal
Utilizing the R.E.N.A.L Nephrometry Score to predict the Surgical Technique and Peri-operative Outcomes of Renal Masses
...Show More Authors

Background: despite the rise in the incidence of renal cell carcinoma attributed to availability of medical imaging, a considerable decline in mortality is an association. Morbidity-wise, the shift from radical nephrectomy to partial nephrectomy is the trend for now. Multiple scoring systems have been introduced over the past decades to help surgeons choose between radical and partial nephrectomy. One commonly used system is the RENAL nephrometry score that was first introduced by Kutikov and Uzzo in 2009.

Objective: to evaluate the role of RENAL nephrometry scoring system in predicting the surgical technique to use to resect renal masses and associated perioperative outcomes.

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Sun Jun 07 2009
Journal Name
Baghdad Science Journal
Investigation of the Optical Properties of the Achromatic Quadrupole Lens by Using the Rectangular Potential Distribution Model
...Show More Authors

An optimization calculation is made to find the optimum properties of combined quadrupole lens which consists of electrostatic and magnetic lens. Both chromatic and spherical aberration coefficients are reduced to minimum values and the achromatic aberration is found for many cases. These calculations are achieved with the aid of transfer matrices method and using rectangular model of field distribution, where the path of charged-particles beam traversing the field has been determined by solving the trajectory equation of motion and then the optical properties for lens have been computed with the aid of the beam trajectory along the lens axis. The computations have been concentrated on determining the chromatic and spher

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Construction Research Congress
Exploratory Study of Potential Negative Safety Outcomes Associated with UAV-Assisted Construction Management
...Show More Authors

Scopus (9)
Scopus
Publication Date
Mon Apr 01 2024
Journal Name
Iraqi Postgraduate Medical Journal
7 SMAS Plasty in Face Lift with Fat Graft: Evaluation of Aesthetic Outcomes
...Show More Authors

ABSTRACT: BACKGROUND: The main goal of facelift surgery is to reduce the effect of aging by reposition of face soft tissue in to more youthful orientation. There are many methods for SMAS plication which had different design and vector of pull. AIM OF STUDY: To evaluate the effectiveness and longitivity of 7 shaped SMAS plication in facelift. PATIENT AND METHODS: From January 2020 to march 2021, 10 female patients with age (45-60) years were presented with facial sagging, those patients were subjected to subcutaneous facelift with 7 shaped SMAS plication with fat greft in Al-Shaheed Ghazi Al-Harri Hospital and Baghdad burn medical center at Baghdad medical complex. RESULTS: The average follow up period was 6 to 12 months. The mean operative

... Show More
Publication Date
Thu Nov 01 2018
Journal Name
Optical Fiber Technology
Enhancing refractive index sensitivity using micro-tapered long-period fiber grating inscribed in biconical tapered fiber
...Show More Authors

View Publication
Scopus (16)
Crossref (16)
Scopus Clarivate Crossref