A piezoelectric cantilever beam with a tip mass at its free end is a common energy harvester configuration. This article introduces a new principle of designing such a harvester that increases the generated power without changing the resonance frequency of the harvester: the attraction force between two permanent magnets is used to add stiffness to the system. This magnetic stiffening counters the effect of the tip mass on the efficient operation frequency. Five set-ups incorporating piezoelectric bimorph cantilevers of the same type in different mechanical configurations are compared theoretically and experimentally to investigate the feasibility of this principle: theoretical and experimental results show that magnetically stiffened harvesters have important advantages over conventional set-ups with and without tip mass. They generate more power while only slightly increasing the deflection in the piezoelectric harvester and they can be tuned across a wide range of excitation frequencies.
In this research, the stopping power and range of protons in biological human soft and hard tissues (blood, brain, skeleton-cortical bone, and skin) of both child and adult are calculated at the energies ranging from 1MeV to 350 MeV. The data is collected from ICRU Report 46 and calculated the stopping power employing the Bethe formula. Moreover, the simple integration (continuous slowing down approximation) method is employed for calculating protons range at the target. Then, the stopping power and range of protons value in human tissues have been compared with the program called SRIM. Moreover, the results of the stopping power vs energy and the range vs energy have been presented graphically. Proper agreement is found between the gain
... Show MoreCultured fruits of theCorundum Coriandrum sativum were sown On 11/11 / 2008 in basins containing 15 kg of soil (Silty Loam) .Fruits were divided into two parts the first was soaked in normanl water and the second was magnetized for a period of 24 hours Irrigation was up to (75% of capacity field.Two types of water (normal water and magnetized water)with three repetitions were used the access to magnetic water was supplied from a special electric device. Recorded measurements were plant height the number of stems / plant, weight of plant, number of flowers, 1000 seed weight) during the cultivation period, which ended on 11/5/2009. Results indicated the absence of any effect of magnetic water on plant growth of Fenugreek while seeds tre
... Show MoreThe Plerion nebula is characterized by its pulsar that fills the center of the supernova remnant with radio and X-ray frequencies. In our galaxy there are nine naked plerionic systems known, of which the Crab Nebula is the best-known example. It has been studied this instance in order to investigate how the pulsar energy affect on the distribution and evolution of the remnant as well as study the pulsar kick velocity and its influence on the remnant. From the obtained results it's found that, the pulsar of the Crab Nebula injects about (2−3)𝑥 1047 erg of energy to the remnant, although this energy is small compared to the supernova explosion energy which is about 1051 erg but still plays a significant role in the distribution and the m
... Show MoreThe energy aimed at examining the mode of energy drinks consumption among athletes in
Baghdad and assessing their drinks were spread greatly among the athletes and students. This
study impression toward such drinks. The study sample comprised of 102 mal athletes aged
between 19-27 years and selected randomly .The obtained results showed that football was
most practiced among the test samples at 40.54% based on twice daily .The athletes
consumed one can each day at 41.18% .As the data on energy drinks was supplied from
friends .The prefared period for drinking was before or during exercise .The athletes thought
that there products can provide energy ,vitamins ,tell ale materials ,does not affect
appetite.The most f
This study investigates the characterization and growth dynamics of a Magnetically Stabilized Gliding Arc Discharge (MSGAD) system, generating non-thermal plasma with argon gas under atmospheric pressure and flow rates of 1-5 L/min. The electrical properties and growth patterns concerning gas flow rates and applied voltages were examined utilizing a magnetic field for stability. Using a digital oscilloscope, a correlation between voltage reduction and increased current was uncovered. An algorithm analyzes digital images to compute arc length, area, and volume. Results reveal how gas flow rate and applied voltage directly impact arc growth. Furthermore, the magnetic field's role in guiding and stabilizing the plasma discharge was explored. T
... Show MoreExamining and comparing the image quality of degenerative cervical spine diseases through the application of three MRI sequences; the Two-Dimension T2 Weighed Turbo Spin Echo (2D T2W TSE), the Three-Dimension T2 Weighted Turbo Spin Echo (3D T2W TSE), and the T2 Turbo Field Echo (T2_TFE). Thirty-three patients who were diagnosed as having degenerative cervical spine diseases were involved in this study. Their age range was 40-60 years old. The images were produced via a 1.5 Tesla MRI device using (2D T2W TSE, 3D T2W TSE, and T2_TFE) sequences in the sagittal plane. The image quality was examined by objective and subjective assessments. The MRI image characteristics of the cervical spines (C4-C5, C5-C6, C6-C7) showed significant difference
... Show MoreThe objective of this study is to examine the properties of Bayes estimators of the shape parameter of the Power Function Distribution (PFD-I), by using two different prior distributions for the parameter θ and different loss functions that were compared with the maximum likelihood estimators. In many practical applications, we may have two different prior information about the prior distribution for the shape parameter of the Power Function Distribution, which influences the parameter estimation. So, we used two different kinds of conjugate priors of shape parameter θ of the <
... Show MoreAn increasing trend to use probiotic and study their effects on the pathogens has been conductor where they are defined as live micro-organisms that give a health benefit to the host when ingested in sufficient quantities, including the yeast Saccharomyces boulardii In addition research show that a magnetic field (MF) has a biological effect. This study aims to investigate the effects of magnetic field on the inhibitory action of Saccharomyces boulardii against bacteria isolated from urinary tract infection, Study the sensitivity of bacterial isolates to antibiotics after diagnosis by microscopic, Cultural and biochemical examinations as well as Api20 E examinations were used gram negative bacteria , Most isolates were resistant to an
... Show MoreThe skill high-jump scoring is based on mechanical and physical abilities. The most important of all is the strength used by the player from the moment of preparation to the moment of scoring, which led the researchers to study the characteristics of the series of power chain functions of this skill according to (Biosyn System) The players of the national team's back line have a handball to find out the relationship between the properties of the power chain curve and the accuracy of the high jump to the upper and lower target angles. The aim of the research was to identify the values of the Force Series variables for the skill of the high-jump curve of the handball as well as the relationship between the properties of the power chain functi
... Show More