Preferred Language
Articles
/
3xaZAowBVTCNdQwCNfWV
Discharge performance assessment of a vertical double-pipe latent heat storage unit equipped with circular Y-shaped fins
...Show More Authors

This paper aims to study the effect of circular Y-shaped fin arrangement to improve the low thermal response rates of a double-tube heat exchanger containing Paraffin phase change material (PCM). ANSYS software is employed to perform the computational fluid dynamic (CFD) simulations of the heat exchanger, including fluid flow, heat transfer, and the phase change process. The optimum state of the fin configuration is derived through sensitivity analysis by evaluating the geometrical parameters of the Y-shaped fin. For the same height of the fins (10 mm), the solidification time is reduced by almost 22%, and the discharging rate is enhanced by almost 26% using Y-shaped fins compared with the straight fins. The results demonstrate that the solidification time is inversely proportional to the fin's length. The heat release rate for the case with the longest fins (stem length of 10 mm) is 39 W, almost 2.8 times higher than that with the fins' stem length of 5 mm. The case with the tributary's angle of 22.5o solidified in 55 min, faster than the other studied angles. Increasing the number of fins significantly affects the solidification time and discharging rate. By increasing the number of fins from 3 to 9, the heat transfer rate improves by 194%. The advantages of circular Y-shaped fins are well known in heat transfer applications and therefore are characterized toward higher performance in this study for the first time during the solidification process.

Scopus Clarivate Crossref
View Publication
Publication Date
Fri Dec 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Laminar Free Convection in Three Dimensional Inclined Porous Annulus with Fins on the Inner Cylinder
...Show More Authors

An experimental and numerical study was carried out to investigate the heat transfer by natural convection in a three dimensional annulus enclosure filled with porous media (silica sand) between two inclined concentric cylinders with (and without) annular fins attached to the inner cylinder under steady state condition. The experiments were carried out for a range of modified Rayleigh number (0.2 ≤Ra*≤ 11) and extended to Ra*=500 for numerical study and for annulus inclination angle of (δ = 0˚, 30˚, 60˚ and 90˚). The numerical study was to give the governing equation under assumptions that used Darcy law and Boussinesq’s approximation and then it was solved numerically using finite difference approximation. It was found that t

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 17 2017
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study Using the Passive Solar Chimney for Evaporative Cooling With PCM and CFM as a Thermal Energy Storage
...Show More Authors

 

      In this work, a test room was built in Baghdad city, with (2*1.5*1.5) m3  in dimensions, while the solar chimneys (SC) were designed with aspect ratio (ar) bigger than 12. Test room was supplied by many solar collectors; vertical single side of air pass with ar equals 25, and tilted 45o double side of air passes with ar equals 50 for each pass, both collectors consist of flat thermal energy storage box collector (TESB) that covered by transparent clear acrylic sheet, third type of collector is array of evacuated tubular collectors with thermosyphon in 45o instelled  in the bottom of TESB of vertical SC. The TESB was

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 30 2013
Journal Name
Australian Journal Of Basic And Applied Sciences
CFD Simulation of Heat Transfer Augmentation in Constant Heat-Fluxed Tube fitted with Baffled Twisted Tape Inserts
...Show More Authors

Publication Date
Sat Feb 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Behavior of passive single pipe pile in sandy soil
...Show More Authors
Abstract<p>This research focuses on studying the effects of soil movement on the behavior of an existing pile driven in sandy soil. A physical model has been manufactured to investigate the effect of construction of an embankment adjacent to free head single pile driven in sand of dry unit weight of 13.5 kN/m<sup>3</sup>. The model pile of diameter (D) of 10 mm are tested under two conditions of loading: loaded axially and without load. The model piles are instrumented with strain gauges along the embedded length to measure strains resulting from the soil movement. The embankment loads are applied at distances of 2.5, 5, and 10D from the edge of the pile. The results obtained from the </p> ... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Aug 13 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Edge Detection Using Circular Sliding Window
...Show More Authors

    In this paper, we devoted to use circular shape sliding block, in image edge determination. The circular blocks have symmetrical properties in all directions for the mask points around the central mask point. Therefore, the introduced method is efficient to be use in detecting image edges, in all directions curved edges, and lines. The results exhibit a very good performance in detecting image edges, comparing with other edge detectors results.

View Publication Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Al-khwarizmi Engineering Journal
A Methodology for Evaluating and Scheduling Preventive Maintenance for a Thermo-Electric Unit Using Artificial Intelligence
...Show More Authors

Flow-production systems whose pieces are connected in a row may not have maintenance scheduling procedures fixed because problems occur at different times (electricity plants, cement plants, water desalination plants). Contemporary software and artificial intelligence (AI) technologies are used to fulfill the research objectives by developing a predictive maintenance program. The data of the fifth thermal unit of the power station for the electricity of Al Dora/Baghdad are used in this study. Three stages of research were conducted. First, missing data without temporal sequences were processed. The data were filled using time series hour after hour and the times were filled as system working hours, making the volume of the data relativel

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Wed Jun 06 2001
Journal Name
مجلة العلوم الاقتصادية والادارية
Double cross-over and cross-over with extra period designs -comparative study-
...Show More Authors

The goal of the research is to find the optimization in the test of the appropriate cross-over design for the experiment that the researcher is carrying out (under assumption that there are carry-over effects of the treatments) to posterior periods after the application period (which is often assumed to be the first period). The comparison between the double cross-over design and the cross-over design with extra period. The similarities and differences between the two designs were studied by measuring the Relative Efficiency (RE) of the experiment.

Preview PDF
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
EXPERIMENTAL INVESTIGATION OF LAMINAR NATURAL CONVECTION HEAT TRANSFER IN A RECTANGULAR ENCLOSURE WITH AND WITHOUT INSIDE PARTITIONS
...Show More Authors

Experimental study has been conducted for laminar natural convection heat transfer of air flow through a rectangular enclosure fitted with vertical partition. The partition was oriented parallel to the two vertical isothermal walls with different temperatures, while all the other surfaces of the enclosure were insulated. In this study a test rig has been designed and constructed to allow studying the effect of Rayleigh number, aperture height ratio, partition thickness, the position of aperture according to the side walls and according to the height, the position of the partition according to the hot wall, and partition inclination. The experiments were carried out with air as the working fluid for Rayleigh number range (5*107 – 1.3*10

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Al-kindy College Medical Journal
Microbiological Study of Male ’ s Urethral Discharge
...Show More Authors

Objective: To evaluate male patients complaining of
urethritis clinically according to the isolated organisms.
Method: A total of 100 male patients attending to of
Dermatological and Venereal private clinics for the period
April 2003 to November 2003 were included in the study.
Urethral swab was obtained from each male for culture and
direct immunofluorescence examination was done.
Demographic data was obtained, also.
Results: N. gonorrhoea was the predominate cause of
infection in 22%. A peak of infection was reported in the
second decade of age. Highest rate reported among single
males. A significant association was noticed between
profuse discharge and infection with gonorrhoea.
Conclusion: This

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 23 2020
Journal Name
Journal Of Engineering
Experimental Investigation of Thermal Performance of a Solar Chimney Provided with a Porous Absorber Plate
...Show More Authors

 

Experimental investigation of the influence of inserting the metal foam to the solar chimney to induce natural ventilation are described and analyzed in this work. To carry out the experimental test, two identical solar chimneys (without insertion of metal foam and with insertion of metal foam) are designed and placed facing south with dimensions of length× width× air gap (2 m× 1 m× 0.2 m). Four incline angles are tested (20o,30o,45o,60o) for each chimney in Baghdad climate condition (33.3o latitude, 44.4o longitude) on October, November, December 2018. The solar chimney performance is investigated by experimentally recording absorber pl

... Show More
View Publication Preview PDF
Crossref (5)
Crossref