Preferred Language
Articles
/
3xZhZ4cBVTCNdQwCjEng
Determination of a time-dependent thermal diffusivity and free boundary in heat conduction
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Thu Jan 31 2019
Journal Name
Journal Of Engineering
CFD Application on Shell and Double Concentric Tube Heat Exchanger
...Show More Authors

This work is concerned with the design and performance evaluation of a shell and double concentric tubes heat exchanger using Solid Works and ANSY (Computational Fluid Dynamics).

Computational fluid dynamics technique which is a computer-based analysis is used to simulate the heat exchanger involving fluid flow, heat transfer. CFD resolve the entire heat exchanger in discrete elements to find: (1) the temperature gradients, (2) pressure distribution, and (3) velocity vectors.  The RNG k-ε model of turbulence is used to determining the accurate results from CFD.

The heat exchanger design for this work consisted of a shell and eight double concentric tubes. The number of inlets are three and that of o

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Jul 01 2012
Journal Name
International Journal Of Computer Mathematics
Numerical solution of the two-dimensional Helmholtz equation with variable coefficients by the radial integration boundary integral and integro-differential equation methods
...Show More Authors

View Publication
Crossref (12)
Crossref
Publication Date
Sun Jun 21 2020
Journal Name
Baghdad Science Journal
Spectrophotometer Determination of Cefixime in pure form and pharmaceutical preparation by Using Cloud point Extraction
...Show More Authors

Two simple methods spectrophotometric were suggested for the determination of Cefixime (CFX) in pure form and pharmaceutical preparation. The first method is based without cloud point (CPE) on diazotization of the Cefixime drug by sodium nitrite at 5Cº followed by coupling with ortho nitro phenol in basic medium to form orange colour. The product was stabilized and measured 400 nm. Beer’s law was obeyed in the concentration range of (10-160) μg∙mL-1 Sandell’s sensitivity was 0.0888μg∙cm-1, the detection limit was 0.07896μg∙mL-1, and the limit of Quantitation was 0.085389μg∙mL-1.The second method was cloud point extraction (CPE) with using  Trtion X-114 as surfactant. Beer

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Flame Atomic Emission and Colorimetric Methods for the Determination of Cephalexin Monohydrate in Pharmaceutical Preparations
...Show More Authors

We propose two simple, rapid, and convenient spectrophotometric methods which are described for the determination of cephalexin in bulk and its pharmaceutical preparations. They are based on the measurement of the flame atomic emission of potassium ion (in the first method) and colorimetric determination of the green colored solution at 610 nm formed after the reaction of cephalexin with potassium permanganate as an oxidant agent (in the second method) in basic medium. The working conditions of the methods are investigated and optimized. Beer's law plot shows a good correlation in the concentration range of 5-40?g ml-1. The detection limits are 2.573,2.814 ?g ml-1 for the flame emission photometric method and 1.844,2.016 ?g ml-1 for colo

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Bismuth(III) with Arsenazo(III) Reagent in Water samples and Veterinary Preparation
...Show More Authors

A simple , sensitive and accurate spectrophotometric method for the trace determination of bismuth (III) has been developed .This method is based on the reaction of bismuth (III) with arsenazo(III) in acid solution (pH=1.9) to form a blue water soluble complex which exhibits maximum absorption at 612nm .Beer's law is obeyed over the concentration range of 2-85 ?g bismuth (III) in a final volume of 20 mL( i.e. 0.1 – 4.25?g.mL-1) with a correlation coefficient of (0.9981) and molar absorptivity 1.9×104 L.mol-1.cm-1 . The limit of detection (LOD) and the limit of quantification (LOQ) are 0.0633 and 0.0847 ?g.mL-1 , respectively . Under optimum conditions,the stoichiometry of the reaction between bismuth (III) and arsenazo(III) r

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Oct 28 2023
Journal Name
Baghdad Science Journal
Indirect Flow Injection Spectrophotometric and Chromatographic Methods for the Determination of Mebendazole in Pharmaceutical Formulations
...Show More Authors

Chromatographic and spectrophotometric methods for the estimation of mebendazole in
pharmaceutical products were developed. The flow injection method was based on the oxidation of
mebendazole by a known excess of sodium hypochlorite at pH=9.5. The excess sodium hypochlorite is then
reacted with chloranilic acid (CAA) to bleach out its color. The absorbance of the excess CAA was recorded
at 530 nm. The method is fast, simple, selective, and sensitive. The chromatographic method was carried out
on a Varian C18 column. The mobile phase was a mixture of acetonitrile (ACN), methanol (MeOH), water
and triethylamine (TEA), (56% ACN, 20% MeOH, 23.5% H2O, 0.5% TEA, v/v), adjusted to pH = 3.0 with
1.0 M hy

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
New Solar Thermal Materials
...Show More Authors

A number of ehemical ion materials were used as an absorber against solar energy. These materials were selected according to their absorption spectra in the wavelength range 300-800nm where the solar spectrum is coventrated. A solar olleetorw^esigd and The ability of each material inside the collector for absorbing the solar radiation was examined by a converter parameter “R”.According to the “R” parameter, the cohaltous and copperic ions material seems to be of higher capability for absorbing solar energy than the other materials.All the results were analyzed by means of a least-squared fitting program.

View Publication Preview PDF
Crossref
Publication Date
Sun Dec 17 2017
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study Using the Passive Solar Chimney for Evaporative Cooling With PCM and CFM as a Thermal Energy Storage
...Show More Authors

 

      In this work, a test room was built in Baghdad city, with (2*1.5*1.5) m3  in dimensions, while the solar chimneys (SC) were designed with aspect ratio (ar) bigger than 12. Test room was supplied by many solar collectors; vertical single side of air pass with ar equals 25, and tilted 45o double side of air passes with ar equals 50 for each pass, both collectors consist of flat thermal energy storage box collector (TESB) that covered by transparent clear acrylic sheet, third type of collector is array of evacuated tubular collectors with thermosyphon in 45o instelled  in the bottom of TESB of vertical SC. The TESB was

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Determination of environmental lead pollution in Alawi el-hilla and Bab-almudam bus stations in Baghdad city
...Show More Authors

Two main grand bus national stations in Baghdad ( Alawi-alhila and Bab-almudam) were chosen as examples to determine lead effect on its drivers. This lead came from ethyl tetra lead or ethyl tri lead which used to improve gasoline quality ,so these two stations could be consider as two of the most polluted places due to gasoline burned by hundreds cars located in these stations .The determination of environmental lead pollution was measured in blood and urines drivers. Drivers were divided in two main groups due to their ages ( 30 persons in each group). The first group for men of 22-30 years old. The second group for men of 40-60 years old. Those men were carefully chosen in order to be non-fumiers or non-alcoholics persons because of

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples
...Show More Authors

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res

... Show More
View Publication Preview PDF
Crossref