ervical cancer is one of the most frequently diag nosed malignancies representing the fourth leading cause of cancer-related death in females’ worldwide, with approximately 500,000 new cases diagnosed and 280,000 deaths occurring each year. Mxi1, an antagonist of c-Myc, maps to human chromosome 10q24-q25, a region altered in a substantial fraction of prostate tumors, in prostate cancer, where a high frequency of loss and mutation of the MXI1 gene has been reported. The aim of present study was to find out the possible association of exon deletion of MXI1 gene with incidence of cervical abnormalities and cancers in some Iraqi married women. The present study include collection of 120 scraping cervical cells samples from women clinically diagnosed with cervical abnormalities and cancer, and 30 scraping cervical cells samples from apparently healthy women and all these samples were submitted for cytological and histopathological examination. DNA was extracted from all these samples, and then the singleplex PCR was performed with primers targeted the exon1, 2, 3, 4, 5 and 6 of MXI1 gene. The results of cytological examination showed that 30 (25%), 21 (17.5%), 15 (12.5%), 11 (9.16%), 2 (1.66%), 1 (0.83%), 22 (18.33%) and 18 (15%) out of 120 scraping cervical cells samples were detected for ASCUS, LSIL, HSIL, SCC, AGUS, cervicitis, and cervicitis with squamous metaplatia, respectively. Also the results of histopathological examination showed that 32 (26.66%), 19 (15.83%), 17 (14.16%), 11 (9.16%), 1 (0.83%), 22 (18.33%) and 18 (15%) out of scraping cervical cells samples were detected for CINI, CINII, CINIII, SCC
The compressive residual stresses generated by shot peening, is increased in a direct proportional way with shot peening time (SPT). For each metal, there is an optimum shot peening time (O.S.T) which gives the optimum fatigue life. This paper experimentally studied to optimize shot peening time of aluminium alloy 6061-T651 as well as using of and analysis of variance (ANOVA).
Two types of fatigue test specimens’ configuration were used, one without notch (smooth) and the other with a notch radius (1,25mm), each type was shot peened at different time. The (O.S.T) was experimentally estimated to be 8 minutes reaching the surface stresses at maximum peak of -184.94 MPa.
A response surface methodology (RSM) is presen
... Show MoreCopper oxide (CuO) nanoparticles were synthesized through the thermal decomposition of a copper(II) Schiff-base complex. The complex was formed by reacting cupric acetate with a Schiff base in a 2:1 metal-to-ligand ratio. The Schiff base itself was synthesized via the condensation of benzidine and 2-hydroxybenzaldehyde in the presence of glacial acetic acid. This newly synthesized symmetric Schiff base served as the ligand for the Cu(II) metal ion complex. The ligand and its complex were characterized using several spectroscopic methods, including FTIR, UV-vis, 1H-NMR, 13C-NMR, CHNS, and AAS, along with TGA, molar conductivity and magnetic susceptibility measurements. The CuO nanoparticles were produced by thermally decomposing the
... Show MoreThis paper proposes a new approach, of Clustering Ultrasound images using the Hybrid Filter (CUHF) to determine the gender of the fetus in the early stages. The possible advantage of CUHF, a better result can be achieved when fuzzy c-mean FCM returns incorrect clusters. The proposed approach is conducted in two steps. Firstly, a preprocessing step to decrease the noise presented in ultrasound images by applying the filters: Local Binary Pattern (LBP), median, median and discrete wavelet (DWT), (median, DWT & LBP) and (median & Laplacian) ML. Secondly, implementing Fuzzy C-Mean (FCM) for clustering the resulted images from the first step. Amongst those filters, Median & Lap