Abstract. This study presents experimental and numerical investigation on the effectiveness of electrode geometry on flushing and debris removal in Electrical Discharge Drilling (EDD) process. A new electrode geometry, namely side-cut electrode, was designed and manufactured based on circular electrode geometry. Several drilling operations were performed on stainless steel 304 using rotary tubular electrodes with circular and side-cut geometries. Drilling performance was characterized by Material Removal Rate (MRR), Electrode Wear Rate (EWR), and Tool Wear Ratio (TWR). Dimensional features and surface quality of drilled holes were evaluated based on Overcut (OC), Hole Depth (HD), and Surface Roughness (SR). Three-dimensional three-phase CFD models were built using ANSYS FLUENT software to simulate the flow field at interelectrode gap. Results revealed that the overall performance of side-cut electrode was superior due to improved erosion rates and flushing capabilities, resulting in production of deep holes with good dimensional accuracy and surface quality.
We have studied theoretically the response of atomic three- level cascade scheme
of rubidium vapor to a strong laser under conditions in which electromagnetically
induced transparency would be induced on a weak probe beam. We show that the
medium that is an opaque to a probe laser can, by applying both lasers
simultaneously, be made transparent.
There is a suggestion that an antidiuretic hormone-induced decrease in diuresis might contribute to the rapid relief of the acute pain in renal colic. This study was designed to evaluate the efficacy of desmopressin nasal spray compared with diclofenac given intramuscularly in patients with acute renal colic. The study included 75 patients randomized into three different groups; group A received desmopressin (40 μg, nasal spray), group B diclofenac (75 mg) intramuscularly and group C, both desmopressin and diclofenac. Pain was assessed using a visual analogue scale (a 10-cm horizontal scale ranging from `no pain' to `unbearable pain') at baseline, 10, 20 and 30 min after administering t
... Show MoreThis research tests the relationship linkage and effect between the Employees Empowerment Strategy and Organizational Innovation, The research problem is how to understand the Employees Empowerment Strategy role in the achievement Organizational Innovation in Diyala Public Company For Electrical Industrial. A questionnaire was used in data collection depending on the distribution of (32) forms to the research sample. Data were analyzed Using (SPSS)program. Using a number of statistical tools for tests the research hypothesis. The research found set of conclusions, one of the most important thinks was, that there is a linkage and impact relation between Employees Empowerment Strategy, its variables, and Organizational Innovation a
... Show MoreA nano manganese dioxide (MnO2) was electrodeposited galvanostatically onto a carbon fiber (CF) surface using the simple method of anodic electrodeposition. The composite electrode was characterized by field emission scanning electron microscopy (FESEM), and X-ray diffraction (XRD). Very few studies investigated the efficiency of this electrode for heavy metals removal, especially chromium. The electrosorption properties of the nano MnO2/CF electrode were examined by removing Cr(VI) ions from aqueous solutions. NaCl concentration, pH, and cell voltage were studied and optimized using the Box-Behnken design (BDD) to investigate their effects and interactions on the electrosorption process. The results showed that the
... Show MoreAccurate estimation of permeability is essential for reliable reservoir characterization and simulation. However, core data are often limited due to their high cost and operational constraints, leading to significant uncertainty in uncored intervals. This study aims to reduce the dependence on core data for permeability estimation by integrating electrofacies derived from well logs and flow zone indicator analysis in the Mishrif Formation, Nasiriyah oil field. Electrofacies were generated using dynamic clustering based on the log data from 13 wells. This led to the identification of five electrofacies units that represent intervals with similar log responses, formed by merging 75 electrofacies, where flow zone indicators analysis id
... Show MoreThis study presents the design, modeling, and experimental evaluation of a three-level electro-hydraulic elevator system controlled by a Delta DVP-20SX2 Programmable Logic Controller (PLC) equipped with an integrated Proportional–Integral–Derivative (PID) module. The PLC, programmed in Ladder Logic using ISPSoft 2.46, regulates cabin motion across all three levels. A detailed MATLAB/Simulink model was developed, incorporating three PID controllers: one for displacement regulation via a proportional directional control valve and two for dynamic pressure regulation using a proportional pressure relief valve. Conventional PID parameters were initially tuned using the trial-and-error method based on time-domain performance indices a
... Show MoreAbstract
quality issue is the only issue the interesting in recent years of the last century, but also came out of sync with the other issue is the issue of environment, Where they have become represent two sides of one currency, challenges faced by the world and raised by the environmental problems have made industrial organizations pay great attention to the environment by improving their environmental performance, and that's where the oil industry is one of the most dangerous industries, influential and damaging to the environment due to the organizations move away from oil for adoption The application of EMS then a tool to improve environmental performance has been chosen sam
... Show MoreFor the past few years, the sediment began to accumulate in Al-Gharraf River which reduces the flow capacity of the River. In the present research, a numerical model was developed using Hec-Ras software, version 5.0.4. to simulate the flow and sediment transport in the upper reach of the river. The hydrological and cross-section data measured by the Ministry of Water Resources, for the reach located between Kut and Hai cities and having a length of 58200 m, was used to perform calibration and verification of the model. Moreover, field sampling of suspended and bed loads was gathered for five months starting from 7/2/2019, and laboratory tests of samples were conducted to be used as in
A cost-effective and efficient detector was created to conduct thorough turbidimetric measurements by reaction of Co (II) ion with calcium ferro cyanide to form bright green particulate, using the method of continuous flow injection analysis, the use of NAG-5SX1-1D-SSP Analyzer in determining cobalt (II) ion in a test for the validity of the new design. The NAG-5SX1-1D-SSP Analyzer is composed of five irradiation sources of white snow leds having the diameter of 10 mm with one solar cell of 55 mm length, 13.5 mm width. Using a selector switch to select the optimum voltage to be used which was 2.7 VDC. Under conditions of optimization, cobalt (II) ion was determined at 0.005–20 mmol. L–1(n = 23) while linearity dynamic range 0.005–7 mm
... Show More