Preferred Language
Articles
/
1xjsfpUBVTCNdQwCNy62
Microleakage Evaluation of a Silorane-Based and Methacrylate-Based Packable and Nanofill Posterior Composites (in vitro comparative study)
...Show More Authors

This study compared in vitro the microleakage of a new low shrink silorane-based posterior composite (Filtek™ P90) and two methacrylate-based composites: a packable posterior composite (Filtek™ P60) and a nanofill composite (Filtek™ Supreme XT) through dye penetration test. Thirty sound human upper premolars were used in this study. Standardized class V cavities were prepared at the buccal surface of each tooth. The teeth were then divided into three groups of ten teeth each: (Group 1: restored with Filtek™ P90, Group 2: restored with Filtek™ P60, and Group 3: restored with Filtek™ Supreme XT). Each composite system was used according to the manufacturer's instructions with their corresponding adhesive systems. The teeth were then thermocycled, immersed in 1% methylene blue dye for 24 hours at room temperature, embedded in auto-polymerizing acrylic resin and sectioned longitudinally bucco-lingually. Microleakage was evaluated by assessing the linear dye penetration at the tooth/restoration interface occlusally and gingivally. The highest microleakage score occlusally or gingivally was recorded and the results were analyzed statistically using SPSS version 13. The results of this study showed that the silorane-based posterior composite Filtek™ P90 showed significantly less microleakage than the methacrylate-based packable composite (Filtek™ P60) and the nano-filled composite (Filtek™ Supreme XT) when the tooth-restoration interface is located in enamel.

Preview PDF
Quick Preview PDF
Publication Date
Mon Nov 01 2010
Journal Name
Journal Of Systems And Software
Development of Java based RFID application programmable interface for heterogeneous RFID system
...Show More Authors

View Publication
Scopus (7)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Fme Transactions
Development of automated liquid filling system based on the interactive design approach
...Show More Authors

The automatic liquid filling system is used in different applications such as production of detergents, liquid soaps, fruit juices, milk products, bottled water, etc. The automatic bottle filling system is highly expensive. Where, the common filling systems required to complex changes in hardware and software in order to modify volume of liquid. There are many important variables in the filling process such as volume of liquid, the filling time, etc. This paper presents a new approach to develop an automatic liquid filling system. The new proposed system consists of a conveyor subsystem, filling stations, and camera to detect the level of the liquid at any instant during the filling process. The camera can detect accurately the leve

... Show More
View Publication
Scopus (17)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Advances In Mechanical Engineering
3D-shape formation of blood vessels based on computer aided design system
...Show More Authors

This paper proposes and tests a computerized approach for constructing a 3D model of blood vessels from angiogram images. The approach is divided into two steps, image features extraction and solid model formation. In the first step, image morphological operations and post-processing techniques are used for extracting geometrical entities from the angiogram image. These entities are the middle curve and outer edges of the blood vessel, which are then passed to a computer-aided graphical system for the second phase of processing. The system has embedded programming capabilities and pre-programmed libraries for automating a sequence of events that are exploited to create a solid model of the blood vessel. The gradient of the middle c

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Wed Jul 01 2020
Journal Name
2020 42nd Annual International Conference Of The Ieee Engineering In Medicine & Biology Society (embc)
Recurrent Fusion of Time-Domain Descriptors Improves EMG-based Hand Movement Recognition
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Dec 01 2014
Journal Name
2014 Ieee Student Conference On Research And Development
Feature extraction for co-occurrence-based cosine similarity score of text documents
...Show More Authors

View Publication
Scopus (10)
Crossref (9)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
International Journal Of Advance Science And Technology
MR Images Classification of Alzheimer's Disease Based on Deep Belief Network Method
...Show More Authors

Background/Objectives: The purpose of this study was to classify Alzheimer’s disease (AD) patients from Normal Control (NC) patients using Magnetic Resonance Imaging (MRI). Methods/Statistical analysis: The performance evolution is carried out for 346 MR images from Alzheimer's Neuroimaging Initiative (ADNI) dataset. The classifier Deep Belief Network (DBN) is used for the function of classification. The network is trained using a sample training set, and the weights produced are then used to check the system's recognition capability. Findings: As a result, this paper presented a novel method of automated classification system for AD determination. The suggested method offers good performance of the experiments carried out show that the

... Show More
Publication Date
Tue Mar 25 2014
Journal Name
Sensors
Minimal Camera Networks for 3D Image Based Modeling of Cultural Heritage Objects
...Show More Authors

View Publication
Scopus (38)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Wed Sep 30 2020
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Estimation of Minimum Miscibility Pressure for Hydrocarbon Gas Injection Based on EOS
...Show More Authors

The important parameter used for determining the probable application of miscible displacement is the MMP (minimum miscibility pressure). In enhanced oil recovery, the injection of hydrocarbon gases can be a highly efficient method to improve the productivity of the well especially if miscibility developed through the displacement process. There are a lot of experiments for measuring the value of the miscibility pressure, but they are expensive and take a lot of time, so it's better to use the mathematical equations because of it inexpensive and fast. This study focused on calculating MMP required to inject hydrocarbon gases into two reservoirs namely Sadi and Tanomaa/ East Baghdad field. Modified Peng Robenson Equation of State was

... Show More
View Publication
Crossref
Publication Date
Sat Mar 31 2018
Journal Name
Journal Of Engineering
Estimation of Minimum Miscibility Pressure for 〖CO〗_2 Flood Based on EOS
...Show More Authors

CO2 Gas is considered one of the unfavorable gases and it causes great air pollution. It’s possible to decrease this pollution by injecting  gas in the oil reservoirs to provide a good miscibility and to increase the oil recovery factor. MMP was estimated by Peng Robinson equation of state (PR-EOS). South Rumila-63 (SULIAY) is involved for which the miscible displacement by  is achievable based on the standard criteria for success EOR processes. A PVT report was available for the reservoir under study. It contains deferential liberation (DL) and constant composition expansion (CCE) tests.  PVTi software is one of the (Eclipse V.2010) software’s packages, it has been used to achieve the goal.  Many trials have been done to ma

... Show More
Crossref
Publication Date
Sat Mar 31 2018
Journal Name
Journal Of Engineering
Estimation of Minimum Miscibility Pressure for 〖CO〗_2 Flood Based on EOS
...Show More Authors

CO2 Gas is considered one of the unfavorable gases and it causes great air pollution. It’s possible to decrease this pollution by injecting  gas in the oil reservoirs to provide a good miscibility and to increase the oil recovery factor. MMP was estimated by Peng Robinson equation of state (PR-EOS). South Rumila-63 (SULIAY) is involved for which the miscible displacement by  is achievable based on the standard criteria for success EOR processes. A PVT report was available for the reservoir under study. It contains deferential liberation (DL) and constant composition expansion (CCE) tests.  PVTi software is one of the (Eclipse V.2010) software’s packages, it has been used to achieve the goal.

... Show More
View Publication Preview PDF
Crossref