This work focuses on the preparation of pure nanocrystalline SnO2 and SnO2:Cu thin films on cleaned glass substrates utilizing a sol-gel spin coating and chemical bath deposition (CBD) procedures. The primary aim of this study is to investigate the possible use of these thin films in the context of gas sensor applications. The films underwent annealing in an air environment at a temperature of 500 ◦C for duration of 60 minutes. The thickness of the film that was deposited may be estimated to be around 300 nm. The investigation included an examination of the structural, optical, electrical, and sensing characteristics, which were explored across various preparation circumstances, specifically focusing on varied concentrations of Cu-doping (2, 4, and 6 wt.%). The deposited films were analyzed by several techniques, including X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM), and optical absorption spectroscopy. The films generated by the spin coating method had a tetragonal rutile structure, while the films created via the chemical bath deposition (CBD) technique displayed both tetragonal rutile and orthorhombic structures. The spin coating technique was used to make films of several weight percentages (0, 2, 4, and 6 wt.%). The resulting crystallite sizes were examined and found to be 23 nm, 18 nm, 14 nm, and 10.5 nm, respectively. Similarly, films made using the chemical bath deposition (CBD) method exhibited crystallite sizes of 22, 13.9, 9.3, and 8.15 nm, respectively. The obtained findings from atomic force microscopy (AFM) and scanning electron microscopy (SEM) analyses indicate a consistent trend whereby, as the concentration of Cu-doped material rises, there is a decrease in the average grain size. The transmittance and absorbance spectra were examined within the wavelength range of 300 to 1000 nm. The films generated by both approaches exhibit a significant level of light transmission throughout the visible spectrum. The bandgap energy of spin coating and CBD films decreases with increasing Cu-doped concentrations; the values were (3.88, 3.8, 3.68, and 3.63) eV and (3.8, 3.78, 3.66, and 3.55) eV, respectively. The electrical characteristics of the films include direct current (DC) electrical conductivity, which indicates the presence of two activation energies, Ea1 and Ea2. These activation energies exhibit an upward trend when the concentration of Cu doping is increased. The films were examined for their ability to detect carbon monoxide (CO) gas at a concentration of about 50 ppm at normal room temperature conditions. The sensitivity of the films to carbon monoxide (CO) gas was assessed at various time intervals and temperatures. The results indicated that the film generated using spin coating exhibited a notably high sensitivity at a temperature of 200 °C, while the film prepared using the chemical bath deposition (CBD) approach had heightened sensitivity at a temperature of 150 °C. Keywords: Spin coating, SnO2 thin films, CBD, AFM, XRD, gas sensor.
MRY *Khalid Sh. Sharhan, *Naseer Shukur Hussein, INTERNATIONAL JOURNAL OF DEVELOPMENT IN SOCIAL SCIENCE AND HUMANITIES, 2021
Abstract Background: Kaposi’s sarcoma (KS) is an angioproliferative neoplastic disorder that occurs in different epidemiological forms. Human Herpesvirus type 8 (HHV-8) is established as a causative agent of KS that has been mentioned in textbooks and literature. In the last two decades, KS cases were up searched through many Iraqi medical researches which have been published, but unfortunately, none of which had confirmed this association. Objectives: To assess the association of latent nuclear antigen-1(LANA-1) of HHV-8 among KS patients with clinicopathological parameters and to evaluate if this procedure is valuable for diagnosing this disease through the first immunohistochemical study in Iraq. Methods: This is a clinico-immunohis
... Show MoreThe aim of the research is to indicate the degree of arrangement of the tax branches discussed and the level of efficiency of their performance according to the dimensions approved in the tax diagnostic tool (TADAT). The checklist has been approved as a main tool in collecting data and information from the tax branches of the General Authority for Taxes and the number (8) branches represented by (Karrada , Karakh Center, Al-Rusafa, New Baghdad, Al-Dora, Karakh Al-Tafim, Al-Kadhimiya, Al-Bayaa), The statistical program (spss) was used to calculate the weighted arithmetic media, and we reached the research to a number of conclusions, the most important of which were: - Each of the subsections (Karkh Al-Ahram and Karrada) achieved an
... Show MoreHere, a high sensitive method for biomarker identification according to nanostructure, using enzyme-linked immunosorbent assays (ELISAs), called Nano-ELISA, was presented. Different shapes of gold nanostructures (star and sphere; GNSs and GNPs) with a particle size of 40 nm for sphere particles were altered with a monoclonal antibody (Ab) as a detector Ab. To amplify the optical signal, gold nanostructures were employed as carriers of the signaling specific antibody against insulin growth factor binding protein- 3 (IGFBP-3). The substrate was catalytically oxidized by the Horseradish Peroxidase (HRP) conjugated gold nanostructure, and HRP also enhanced the optical signals, reflecting the amount of the targeting IGFBP-3. In comparison to t
... Show MoreBackground: The clinical examination is one of the best suitable methods for diagnosis of low backache. Backache is one disease that the signs, clinical examination finding, and the results on imaging modalities not always related. The straight leg raising (SLR) and slump tests, can be used for diagnosis of lumber disc herniation. Objectives: To compare the result of the slump test and SLR test in the diagnosis of lumber disc herniation. Subjects and Methods: A prospective comparative study conducts on 280 patients in Al-Kindy teaching and private clinics complaints of backache, aging between 18-70 years old with acute or recurrent backache, sciatica pain, or low back and sciatica pain for last 12 weeks, while patients
... Show MoreBackground: This in vitro study compares a novel calcium-phosphate etchant paste to conventional 37% phosphoric acid gel for bonding metal and ceramic brackets by evaluating the shear bond strength, remnant adhesive and enamel damage following water storage, acid challenge and fatigue loading. Material and Methods: Metal and ceramic brackets were bonded to 240 extracted human premolars using two enamel conditioning protocols: conventional 37% phosphoric acid (PA) gel (control), and an acidic calcium-phosphate (CaP) paste. The CaP paste was prepared from β-tricalcium phosphate and monocalcium phosphate monohydrate powders mixed with 37% phosphoric acid solution, and the resulting phase was confirmed using FTIR. The bonded premolars were exp
... Show MoreThis paper provides an identification key to the species of Orthetrum Newman, 1833 (Odonata, Libellulidae), including six species that were collected from different localities in Iraq.
The species of O. anceps (Schneider, 1845) is registered as a new record in Iraq; the most important characters which are used in diagnostic key are included
Numerical investigation has been carried out on heat transfer and friction factor characteristics of copper-water nanofluid flow in a constant heat-fluxed tube with the existence of new configuration of vortex generator using Computational Fluid Dynamics (CFD) simulation. Two types of swirl flow generator: Classical twisted tape (CTT) and Parabolic-cut twisted tape (PCT) with a different twist ratio (= 2.93, 3.91 and 4.89) and different cut depth (= 0.5, 1.0 and 1.5 cm) with 2% and 4% volume concentration
... Show MoreIn this study the Entrance Surface Dose (ESD) received by pediatrics patients undergoing chest, abdomen and skull X-ray examinations was estimated. The study was conducted in two hospitals in Najaf city where three radiographic systems were considered. The study participants were classified into four age groups 0-1 , 1-5 , 5-10 and 10-15 years. Calculations were performed using exposure factors, kVp, mAs and focal-skin distance, together with patient data age. The ESD was calculated for the involved patients who underwent an Antero-posterior (AP) chest, abdomen and skull X-ray examination. The resulted data were analyzed and compared with international dose references. For all studied radiographic examinations and all X-ray mac
... Show More