Preferred Language
Articles
/
1hdIfY8BVTCNdQwCW3lX
Preparation and characterization DLC thin films using atmospheric pressure plasma Jet
...Show More Authors

Diamond-like carbon, amorphous hydrogenated films forms of carbon, were pretreated from cyclohexane (C6H12) liquid using plasma jet which operates with alternating voltage 7.5kv and frequency 28kHz. The plasma Separates molecules of cyclohexane and Transform it into carbon nanoparticles. The effect of argon flow rate (0.5, 1 and 1.5 L/min) on the optical and chemical bonding properties of the films were investigated. These films were characterized by UV-Visible spectrophotometer, X-ray diffractometer (XRD) Raman spectroscopy and scanning electron microscopy (SEM). The main absorption appears around 296, 299 and 309nm at the three flow rate of argon gas. The value of the optical energy gap is 3.37, 3.55 and 3.68 eV at a different flow rate of argon gas. For XRD analysis, The presence of diamond peaks and graphite peaks in the x-ray spectrum for these films Indicates that there is an occurrence of local ordered sp3 and sp2 for carbon domains and graphite respectively. Raman spectroscopy analysis revealed two broad bands D band and G band. The upshift of D band of diamond and downshift of the G band of graphite with is indicative of the presence of DLC films.

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Nov 02 2021
Journal Name
Indonesian Journal Of Chemistry
Preparation and Characterization of New Tetra-Dentate N<sub>2</sub>O<sub>2</sub> Schiff Base with Some of Metal Ions Complexes
...Show More Authors

This study describes preparation a new series of tetra-dentate N2O2 dinuclear complexes Cr(III), Co(II)and Cu(II) of the Schiff base 2-[5-(2-hydroxy-phenyl)-1,3,4-thiadiazol-2-ylimino]-methyl-naphthalen-1-ol], (LH2) derived from 1-hydroxy-naphthalene-2-carbaldehyde with 2-amino-5-(2-hydroxy-phenyl)-1,3,4-thiadiazole. These ligands were characterized by FT-IR, UV-Vis, Mass spectra, elemental analysis, and 1H-NMR. All prepared complexes have been characterized by conductance measurement, magnetic susceptibility, electronic spectra, infrared spectrum, thermal Analysis (TGA), and metal analysis by atomic absorption. The stoichiometry of metal to ligand, magnetic susceptibility, and electronic spectra measurements show an octahedral geom

... Show More
View Publication
Scopus (17)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Oct 17 2025
Journal Name
Ieee Access
Optic Flow-Based Gait Symmetry Assessment of Center and Peak Pressure Trajectories Applied to Foot Deformities
...Show More Authors

Analyzing plantar pressure trajectories is crucial for assessing foot behavior in dynamic gait stability. We propose the identification of foot symmetry and the detection of deformities by analyzing the trajectories of the center of pressure (CoP) and peak pressure (PP). First, using a foot pressure mapping system, plantar pressure data are acquired during a normal gait cycle. After the data have been acquired, post processing extracts both the CoP and PP trajectories over the spatiotemporal domain of foot motion for each foot independently. For this purpose, we used the optical flow technique which accurately estimates the direction of foot motion. The extracted trajectories of each foot are then segmented into, the medial and lateral regi

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Tue Mar 06 2007
Journal Name
Iraqi J Pharm Sci,
Effect of Silibinin in Lowering the Intraocular Pressure in Normotensive Rabbits: Interaction with Pilocarpine and Cyclopentolate
...Show More Authors

Previous data indicated the effectiveness of silibinin as intraocular pressure (IOP) - lowering agent. The present study was performed to evaluate the interaction of silibinin with pilocarpine or cyclopentolate in lowering IOP in normotensive rabbits. The effects of topically instilled silibinin hemisuccinate solution (0.75%) alone or adjunctly combined with 2% pilocarpine or 1% cyclopentolate on the IOP of normotensive rabbits were evaluated using indentation tonometry. The results showed that 0.75% solution of silibinin was found more potent than pilocarpine (2% drops) in lowering IOP of normotensive rabbits, while their combination results in longer duration of action. Moreover, the elevated IOP values produced by cyclopentolate (1%drops

... Show More
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Effect of Silibinin in Lowering the Intraocular Pressure in Normotensive Rabbits: Interaction with Pilocarpine and Cyclopentolate
...Show More Authors

Previous data indicated the effectiveness of silibinin as intraocular pressure (IOP) - lowering agent.  The present study was performed to evaluate the interaction of silibinin with pilocarpine or cyclopentolate in lowering IOP in normotensive rabbits. The effects of topically instilled silibinin hemisuccinate solution (0.75%) alone or adjunctly combined with 2% pilocarpine or 1% cyclopentolate on the IOP of normotensive rabbits were evaluated using indentation tonometry. The results showed that 0.75% solution of silibinin was found more potent than pilocarpine (2% drops) in lowering IOP of normotensive rabbits, while their combination results in longer duration of action. Moreover, the elevated IOP values produced by cyclopentolate

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Minar International Journal Of Applied Sciences And Technology
Electron density spectroscopic measurement in Al laser induced plasma
...Show More Authors

Plasma generated by a 1064 nm pulsed Nd: YAG laser with pulse duration of 10 ns concentrated onto an Al solid target under vacuum pressure was examined spectroscopically. The temperature and electron density specifying the plasma were measured by time-resolved spectroscopy of neutral atom and ion line emissions in the time period range of 300–2000 ns. An echelle spectrograph is utilized to appear the plasma emission lines. The temperature was obtained using the spectral line comparison method and the electron density was calculated using the Stark Broadening (SB) method. The electron density was characterized as a function of laser pulse energy. The time range where the plasma is optically thin and is also in local thermodynamic equilibri

... Show More
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Measuring of Plasma Melatonin Level in Patients with Preeclampsia
...Show More Authors

Background: disturbed physiological rhythm of blood pressure in preeclampsia is a common finding. The role of oxidative stress in pathogenesis of preeclampsia is well accepted. Melatonin is a powerful free radical scavenger so it's rapidly consumed by enhanced reactive oxygen species in preeclampsia causing non-dipping in blood pressure.Objective: To evaluate the change in plasma melatonin levels in patients with preeclampsia and its relationship with blood pressure.Patients and methods: In this prospective case control study a total of 40 primigravidae pregnant women were recruited during the period of 11 months between August 2015 and August 2016 in Baghdad teaching hospital, medical city, Iraq, divided into two groups:First group

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Fri Dec 03 2021
Journal Name
Journal Of Optoelectronic And Biomedical Materials
Antibacterial activity with eggshell nanoparticles activated by microwave plasma.
...Show More Authors

The eggshell cuticle is the proteinaceous outermost layer of the eggshell which regulates water exchange and protects against entry of micro-organisms. Outer eggshell and cuticle protein was extracted from domestic chicken. The aim of the research is to find out the effect of the treated and untreated nano particles of egg shells with micro wave cold plasma on the effectiveness of E. coli (negative bacteria) that infect the skin and measure the diameter of bacterial inhibition zone, the eggshell has been prepared by a chemical method (sol gel) and measure the level of acidity and the PH is neutral. The result of Atomic Force Microscope (AFM) shows that the particles diameters become smaller with nano-particles solution than for egg

... Show More
Preview PDF
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic Diagnostic of Cadmium Sulfide Plasma Produced By LIBS
...Show More Authors

Abstract

       The current study was carried out to reveal the plasma parameters such as ,the electron temperature ( ), electron density (ne) , plasma frequency (fp), Debye length ( ) , Debye number (   for  CdS to employ the LIBS for the purpose of analyzing and determining spectral emission lines using . The results of electron temperature for CdS range (0.746-0.856) eV , the electron density(3.909-4.691)×1018 cm-3. Finally ,we discuss plasma parameters of CdS  through  nano second  laser generated plasma .

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu May 30 2024
Journal Name
Iraqi Journal Of Science
Plasma Optical Emission Spectroscopy Study of Some Iron Meteorites
...Show More Authors

This study aims to analyze spectra in real-time for λ Draconids, σ Hydrids, μ Virginid, and one sporadic meteor using spectroscopic chemical analysis and diagnose plasma parameters. Good-resolution spectroscopy and a CCD camera for meteor observation were used concurrently to examine the ablation spectra of these meteorites in situ. The Boltzmann and Lorentz methods were then used to determine the temperature and density of electrons, the length of Debye, and the frequency of plasma. Furthermore, spectra data can be analyzed and compared to data from other sources. Spectrum tests can be utilized to identify the chemical structure of meteorites' plasma.

Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon Feb 25 2019
Journal Name
Iraqi Journal Of Physics
Strain specificity in antimicrobial activity of non-thermal plasma
...Show More Authors

Non-thermal (low-temperature) plasma may act as an alternative approach to control superficial wound and skin infections when the effectiveness of chemical agents is weak due to natural pathogen or biofilm resistance. In this paper an atmospheric pressure plasma needle jet device which generates a cold plasma jet is used to measure the effectiveness of plasma treatment against different pathogenic bacteria and to test the individual susceptibility of pathogenic bacteria to non-thermal argon plasma. It is found that, Gram-negative bacteria were more susceptible to plasma treatment than Gram-positive bacteria. For the Gram-negative bacteria Pseudomonas aeruginosa, there were no survivors among the initial 1x108C.F.U (Co

... Show More
View Publication Preview PDF
Crossref (3)
Crossref