Low-temperature stratification, high-volumetric storage capacity, and less-complicated material processing make phase-changing materials (PCMs) very suitable candidates for solar energy storage applications. However, their poor heat diffusivities and suboptimal containment designs severely limit their decent storage capabilities. In these systems, the arrangement of tubes conveying the heat transport fluid (HTF) plays a crucial role in heat communication between the PCM and HTF during phase transition. This study investigates a helical coil tube-and-shell thermal storage system integrated with a novel central return tube to enhance heat transfer effectiveness. Three-dimensional computational fluid dynamics simulations compare the proposed design against a baseline helical coil system without a return tube under equivalent conditions. Outcomes quantify the return tube's efficacy in augmenting heat transfer uniformity and accelerating phase transition. Adding the return tube markedly boosts heat storage and recovery rates, increasing charging by 88% and discharging by 56% versus the baseline. Moreover, total phase transition time reduces by 48% for melting and 36% for solidification with the return tube. The accelerated charging stems from sustained convective heat transfer inside the return tube even as the molten layer thickens. Meanwhile, enhanced solidification results from ongoing cooling of inner regions. Isotherm analysis visualizes the return tube's efficacy in maintaining thermal uniformity throughout the phase transition process. Overall, the return tube significantly improves PCM thermal response, demonstrating a novel but straightforward approach to address heat transfer limitations in latent thermal storage systems.
Despite the availability of information technology banking features and benefits of the banking sector, they involve many risks and challenges and put in the face of the administrative authorities and regulatory institutions in the banking system, organizational matters and control sensitive and bear direct responsibility for conducting independent assessments of their regulatory and information and determine the degree of its durability and its ability to confront problems imposed by the technical challenges and technological .
And the success of the administrative authorities and regulatory institutions in achieving its objectives in the management of risks and threats oversight resulting from the act
Search Results at the International Journal of Science and Research (IJSR)
The Nano materials play a very important role in the heat transfer enhancement. An experimental investigation has been done to understand the behaviors of nano and micro materials on critical heat flux. Pool boiling experiments have used for several concentrations of nano and micro particles on a 0.4 mm diameter nickel chrome (Ni-Cr) wire heater which is heated electrically at atmospheric pressure. Zinc oxide(ZnO) and silica(SiO2) were used as a nano and micro fluids with concentrations (0.01,0.05,0.1,0.3,0.5,1 g/L), a marked enhancement in CHF have been shown in the results for nano and micro fluids for different concentrations compared to distilled water. The deposition of the nano particles on the heater surface was the rea
... Show MoreThe Early-Middle Miocene succession in Iraq is represented by the Serikagni, Euphrates and Dhiban formations, which deposited during the Early Miocene. The Jeribe and Fatha successions were deposited during Middle Miocene age. This study includes microfacies analysis, depositional environments, sequence stratigraphy and basin development of Early – middle Miocene in Hamrin and Ajeel oil fields and Mansuriyha Gas Field. The study area includes four boreholes in three oil fields located in central Iraq: Hamrin (Hr-2) and Ajeel (Aj-13, and 19) oil feilds, and Mansuriyha (Ms-2) Gas Field. Five facies associations were distinguished within the studied fields: deep marine, slop, platform-margin, open marine, restricted interior platform
... Show MoreThe study is situated in the Kokoe Region of Central Buton Regency, Southeast Sulawesi, specifically in the southern part of Kabaena Island. Its primary objective is to assess the potential of nickel laterite in the designated area. The research methodology involved microscopic analysis of bedrock using a polarizing microscope, examining the drilling data, including logging descriptions, and utilizing XRF geochemical analysis (Ni, Fe, Al2O3, Co, Mg, and SiO2) from 32 drilling sites. Both elementary grade and laterite profiles were visualized using Strater 5 software to simplify the representation of laterite profiles. Petrographic analysis divided the bedrock into two lithological units: serpentinized lherzolite and serpentinite. Th
... Show MoreThis work investigates the effect of earthquakes on the stability of a collective pile subjected to seismic loads in the soil layer. Plaxis 3D 2020 finite element software modeled pile behavior in dry soils with sloping layers. The results showed a remarkable fluctuation between the earthquakes, where the three earthquakes (Halabja, El Centro, and Kobe) and the acceleration peak in the Kobe earthquake had a time of about 11 seconds. Different settlement results were shown, as different values were recorded for the three types of earthquakes. Settlement ratios were increased by increasing the seismic intensity; hence the maximum settlement was observed with the model under the effect of the Kobe earthquake (0.58 g), where
... Show MoreTHE ROLE OF ELECTRONIC-PAYMENT SERVICE PROVIDERS IN THE DEVELOPMENT OF E-BANKING IN IRAQ - AN APPLIED RESEARCH IN CENTRAL BANK OF IRAQ
Refrigerant R134a has been widely utilized in automotive air conditioning systems (AACSs); R134a has a high global warming potential (GWP) of 1430 despite having zero ozone depletion potential (ODP). Coming refrigeration systems must include refrigerants with low GWP and zero ODP. The aim of this experimental study is to evaluate the thermal performance of an (AAC) with different values of compressor speeds, i.e., (1000, 1700, and 2400 rpm) and two thermal loads, i.e., (500 and 1000 Watt) with the absence and presence of liquid suction heat exchanger (LSHX) using R134a. The results showed that adding LSHX enhanced the COP cycle by 7.18%, 10.7%, and 3.09% for the first, second, and third speed, respectively, at 500 Watt, while the en
... Show More