Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for the purpose of orthodontic treatment and with fully-formed roots, were used in this study. Endodontic access cavity was prepared in each tooth and canal patency up to the apical foramen was checked with a #15 stainless steel K-file. No root canal preparation was performed. Root canal length measurement was done directly and electronically using two apex locators (Joypex 5 and Root ZX). Direct measurement of the root canal length was done by introducing a #15 K-file inside the root canal until its tip was just visible at the apical foramen, then removed from the root canal and its length was measured (in mm) and subtracted by 0.5 mm. For electronic measurement, the teeth were fixed in a sponge soaked in saline and the root canals were also filled with saline. The lip electrode was attached to the sponge and the apex locators were used according to the manufacturers' instructions. The file holder was clipped to the metal shaft of a #15 K-file and the file was then inserted inside the root canal and advanced until the display reading on the LCD of the apex locator was "0.5". The file was then removed from the root canal and its length was measured (in mm). The differences between the readings of each apex locator and the actual length of each canal were computed, and the results were analyzed statistically by paired t-test using SPSS Version 13. Results: The results of this study showed that the Joypex 5 apex locator showed a lower mean difference than the Root ZX apex locator as compared with the actual length, which was statistically significant (p<0.05). Concerning the accuracy of the two apex locators, Joypex 5 apex locator recorded the apical constriction exactly in 67%, while the Root ZX apex locator in only 25%. Within ±0.5 mm from the actual length, the accuracy of the Joypex 5 and the Root ZX were 83% and 67%, respectively. Within ±1 mm from the actual length, the accuracy of the Joypex 5 and the Root ZX were 100% and 96%, respectively. Conclusion: The Joypex 5 apex locator which is a fifth generation apex locator was more accurate in recording the apical constriction as compared with the Root ZX apex locator which is a third generation apex locator.
This paper details the process of designing, analysing, manufacturing, and testing an integrated solid-state hydrogen storage system. Analysis is performed to optimise flow distribution and pressure drop through the channels, and experimental investigations compare the effects of profile shape on the overall power output from the fuel cell. The storing of hydrogen is given much attention in the selection of a storage medium, and the effect of a cooling system to reduce the recharging time of the hydrogen storage vessel. The PTFE seal performed excellently, holding pressure over 60 bar, despite requiring changing each time the cell is opened. The assembly of the vessel was simple and straightforward, and there was no indication of pressure
... Show MoreClobetasol propionate (CP) is a super potent corticosteroid widely used to treat various skin disorders such as atopic dermatitis and psoriasis. However, its utility for topical application is hampered due to its common side effects, such as skin atrophy, steroidal acne, hypopigmentation, and allergic contact dermatitis. Microsponge is a unique three-dimensional microstructure particle with micro and nano-meters-wide cavities, which can encapsulate both hydrophilic and lipophilic drugs providing increased efficacy and safety. The aim of the current study is to prepare and optimize clobetasol-loaded microsponges. The emulsion solvent diffusion method is used for the preparation of ethylcellulose (EC)-based microsponges. The impact of
... Show MoreThe research presented the experience of creating a new sustainable city, and this experience of establishing an Eco-City (Environmentally friendly) is considered the first experience in Iraq. The current study stressed the importance of the need for environmental planning in the early stages of planning new cities based on realism in planning, design and implementation. Subsequently, that aims to preserve the ecosystem, which is difficult to compensate if degraded or polluted. The research incorporated environmental planning indicators within sustainable urban planning (Reliance on generating electric power that is based on clean and renewable energy sources, Availability of public t
This contribution investigates structural, electronic, and optical properties of cubic barium titanate (BaTiO3) perovskites using first-principles calculations of density functional theory (DFT). Generalized gradient approximations (GGA) alongside with PW91 functional have been implemented for the exchange–correlation potential. The obtained results display that BaTiO3 exhibits a band gap of 3.21 eV which agrees well with the previously experimental and theoretical literature. Interestingly, our results explore that when replacing Pd atom with Ba and Ti atoms at 0.125 content a clear decrease in the electronic band gap of 1.052 and 1.090 eV located within the visible range of electromagnetic wavelengths (EMW). Optical parameters such as a
... Show MoreInvestigation of mesomorphic properties of new 1,3,4-thiadiazolines (which are synthesised via many steps in Scheme 1) was carried out in this study. These compounds are designed to have a heterocyclic unit, a carboxylate linkage group and a polar ether chain at the end of the molecule adjacent to the benzene ring, which enhance the dipolar interactions forces (varied from one to eight carbons) to investigate the association properties of their phases. The structure of the target compounds and the intermediates were confirmed by 1H NMR, 13C NMR, mass and FTIR spectral techniques. Polarised microscopic studies revealed that all the compounds in the series exhibited enantiotropic liquid crystalline properties. This was further confirmed using
... Show MoreDensity functional theory (DFT) calculations were used to evaluate the capability of Glutamine (Gln) and its derivative chemicals as inhibitors for the anti-corrosive behavior of iron. The current work is devoted to scrutinizing reactivity descriptors (both local and global) of Gln, two states of neutral and protonated. Also, the change of Gln upon the incorporation into dipeptides was investigated. Since the number of reaction centers has increased, an enhancement in dipeptides’ inhibitory effect was observed. Thus, the adsorption of small-scale peptides and glutamine amino acids on Fe surfaces (1 1 1) was performed, and characteristics such as adsorption energies and the configuration with the highest stability and lowest energy were ca
... Show MorePollution of the aquatic environment and the depletion of the natural resource cause imbalance in the natural balance of the river environment and contributes to the deterioration of life and the killing of living organisms. Most of the old and modern cities and urban centers were set up close to the rivers because water enters the main lifeblood and all its facilities. The proximity of cities to rivers caused environmental problems resulting from the dumping of residues of these cities to a large and continuous, these wastes include all uses of the city (industrial, agricultural, residential and commercial) and others. The accumulation of these wastes inside the rivers water kills life and makes them unsuitable for various uses to bury
... Show MoreIn the present study, MIG welding is carried out on low carbon steel type (AISI 1015) by using electrode ER308L of 1.5mm diameter with direct current straight polarity (DCSP). The joint geometry is of a single V-butt joint with one pass welding stroke for different plate thicknesses of 6, 8, and 10 mm. In welding experiments, AISI 1015 plates with dimensions of 200×100mm and edge angle of 60o from both sides are utilized. In this work, three main parameters related to MIG welding process are investigated, which are welding current, welding speed, heat input and plate thickness, and to achieve that three groups of plates are employed each one consists of three plates. The results indicate that increasing the weld heat input (t
... Show MoreThe dose rate for bremsstrahlung radiation from beta particles with energy (1.710) MeV and (2.28) MeV which comes from (32P and 90Y) beta source respectively have been calculated through six materials (polyethylene, wood, aluminum, iron, tungsten and lead) for first shielding material with thickness (x=1) mm which are putting between beta sources and second shield (polyethylene, aluminum and lead) with thickness (1, 2 &4) mm have been calculated. The distance between beta source and second shield is constant (D=1) cm. This dose rate was found by program called Rad Pro Calculator (version 3.26). The results of dose rate of beta particles were plotted as a function to the atomic number (Z) for first shield materials for each
... Show MoreThe aim of the present research is concerned with study the effect of UV radiation on the optical properties at wavelengths 254, 365 nm of pure PC and anthracene doping PC films prepared using the cast method for different doping ratio 10-60 mL. Films of pure PC and anthracene doping PC were aged under UV radiation for periods of up to 360 h. It found that the effect of UV radiation at wavelength 254 nm on the optical properties is great than the effect of UV radiation at wavelength 365 nm. Also, it found that the optical energy gap of pure PC and anthracene doping PC films is stable against radiation.