Preferred Language
Articles
/
1BjhfpUBVTCNdQwC8i4b
Assessment of the accuracy of a fifth generation apex locator (in vitro study)
...Show More Authors

Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for the purpose of orthodontic treatment and with fully-formed roots, were used in this study. Endodontic access cavity was prepared in each tooth and canal patency up to the apical foramen was checked with a #15 stainless steel K-file. No root canal preparation was performed. Root canal length measurement was done directly and electronically using two apex locators (Joypex 5 and Root ZX). Direct measurement of the root canal length was done by introducing a #15 K-file inside the root canal until its tip was just visible at the apical foramen, then removed from the root canal and its length was measured (in mm) and subtracted by 0.5 mm. For electronic measurement, the teeth were fixed in a sponge soaked in saline and the root canals were also filled with saline. The lip electrode was attached to the sponge and the apex locators were used according to the manufacturers' instructions. The file holder was clipped to the metal shaft of a #15 K-file and the file was then inserted inside the root canal and advanced until the display reading on the LCD of the apex locator was "0.5". The file was then removed from the root canal and its length was measured (in mm). The differences between the readings of each apex locator and the actual length of each canal were computed, and the results were analyzed statistically by paired t-test using SPSS Version 13. Results: The results of this study showed that the Joypex 5 apex locator showed a lower mean difference than the Root ZX apex locator as compared with the actual length, which was statistically significant (p<0.05). Concerning the accuracy of the two apex locators, Joypex 5 apex locator recorded the apical constriction exactly in 67%, while the Root ZX apex locator in only 25%. Within ±0.5 mm from the actual length, the accuracy of the Joypex 5 and the Root ZX were 83% and 67%, respectively. Within ±1 mm from the actual length, the accuracy of the Joypex 5 and the Root ZX were 100% and 96%, respectively. Conclusion: The Joypex 5 apex locator which is a fifth generation apex locator was more accurate in recording the apical constriction as compared with the Root ZX apex locator which is a third generation apex locator.

Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 11 2022
Journal Name
Journal Of Research In Medical And Dental Science | Vol. 10 | Issue 1 | January-2022
Esthetic Improvements of Various Degrees of White Spot Lesion Using Resin Infiltration and Micro-Abrasion (An In Vitro Study)
...Show More Authors

Background: White spot lesions are esthetic problems caused by subsurface enamel demineralization that seen as white opacity. Aim of the study: This study aimed to evaluate and to compare the color change after the treatment of the white spot lesions with resin ‹nϔ‹Žtrƒt‹on and micro abrasion. Materials and Methods: rt‹ϔ‹…‹ƒŽ white spot lesions were generated on 48 premolar teeth by the use of a demineralization solution. The teeth were randomly divided using the Diagnodent into three study groups (16 teeth for each group) depending on the depth of the induced lesions: outer enamel, inner enamel and outer dentine. Then each group was fatherly subdivided into two groups (8 teeth for each group) the ϔ‹rst group was treated wit

... Show More
Publication Date
Mon Apr 01 2024
Journal Name
Indian Journal Of Dental Research
Effect of Bisoctrizole on Ultraviolet (UV) Absorption Properties of Silicone and Effect on Surface Roughness - An In Vitro Study
...Show More Authors
Abstract<sec> <title>Background:

Premature degradation is the problem of maxillofacial silicones, significantly affected by ultraviolet exposure, contributing to silicones photodegradation. Degradation necessitates frequent replacement of prostheses that increase the total cost of rehabilitation.

Aims:

This study evaluated the effect of bisoctrizole on the ultraviolet absorption properties of silicone material and the stability of this absorption over time. Also, the bisoctrizole effect on the surface roughness of silicone was evaluated.

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Clinical And Experimental Dentistry
Effect of Incorporating Date Seeds Microparticles on Compressive Strength and Microhardness of Conventional Glass Ionomer (an In Vitro Study)
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Comparative Study of The Amount of Apically Extrusion Of Debris During Root Canal Preparation Using Wave Oneâ„¢, Trushape 3Dâ„¢, Hyflexâ„¢ CM and One Shapeâ„¢ Instrumentation Systems (An In Vitro Study)
...Show More Authors

Background: Many types of instruments and techniques are used in the instrumentation of the root canal system. These instruments and techniques may extrude debris beyond the apical foramen and may cause post-instrumentation complications. The aim of this study was to evaluate the amount of apically extruded debris resulted by using 4 types of nickel-titanium instruments (WaveOne, TRUShape 3D conforming files, Hyflex CM, and One Shape files) during endodontic instrumentation. Materials and methods: Forty freshly extracted human mandibular second premolar with straight canals and a single apex were collected for this study. All teeth were cut to similar lengths. Pre-weighted glass vials were used as collecting containers. Samples were randoml

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Sep 26 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the Efficiency of Three Different Obturation Techniques to Obturate the Isthmus Area of Roots Canals Prepared by Two Different Instrumentation Techniques (An In Vitro Study)
...Show More Authors

Background: The isthmus is a difficult area in the root canal complex to manage. The research aimed to evaluate the efficiency of three different obturation techniques (lateral condensation, EandQ (thermoplasticized gutta percha system) and Soft Core (thermoplasticized core carrier gutta percha system)) to obturate the isthmus area of roots prepared by two different instrumentation techniques (rotary ProTaper universal and ProTaper Next systems). Material and method: Sixty freshly extracted teeth were randomly divided into two main groups (A and B) of 30 teeth each. Group A was prepared by rotary ProTaper Universal whereas group B was prepared by ProTaper Next system. Each main group was then randomly subdivided into three subgroups of 10 t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
The role of some types of erythrocytes on the growth of Entamoeba histolytica trophozoite in vitro
...Show More Authors

The parasite E.histolytica was first isolated from a stool sample, and then cultivated and maintained in vitro using Locke-egg medium (LEM) and Liver infusion agar medium (LIAM) . Then, the effect of some types of erythrocytes (human and sheep), on the growth and activity of the parasite in the two culture media was investigated. The parasite was able to ingest and lysis erythrocytes of human and sheep that were supplemented to the culture media and such manipulation was able to augment the reproduction rate of the cultivated E. histolytica, however, such consequence was media- and concentration-dependent. The reproduction rate was significantly increased (66.0, 57.5 and 58.6%, respectively) in LEM medium containing human erythrocytes ty

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Salivary Secretory Immunoglobulin A (sIg A) Level during Fixed Orthodontic Treatment
...Show More Authors

Background: The immune system of the oral cavity suffers alterations due to fixed orthodontic treatment which act as potent stimulus for oral secretory immunity. The aims of this study are to estimate the effect of fixed orthodontic appliance on the level of salivary sIgA at different time intervals, and to verify the gender difference. Materials and method: The patient's history, clinical examination, and fixed orthodontic appliances were placed for 30 Iraqi orthodontic adult patients had class II division 1 and/ or class I malocclusion (15 males and 15 females) aged 18-25 years old. The unstimulated whole saliva was collected from each sample immediately before wearing fixed appliance (control group T0 as base line), and after 2 weeks (T1

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Clinical And Experimental Dentistry
Comparison of the accuracy of intraoral digital impression system and conventional impression techniques for multiple implants in the full-arch edentulous mandible
...Show More Authors

View Publication
Scopus (9)
Crossref (12)
Scopus Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Improving the Performance of Constructed Wetland Microbial Fuel Cell (CW- MFC) for Wastewater Treatment and Electricity Generation
...Show More Authors

The current study deals with the performance of constructed wetland (CW) incorporating a microbial fuel cell (MFC) for wastewater treatment and electricity generation. The whole unit is referred to as CW-MFC. This technique involves two treatments; the first is an aerobic treatment which occurs in the upper layer of the system (cathode section) and the second is anaerobic biological treatment in the lower layer of the system (anode section). Two types of electrode material were tested; stainless steel and graphite. Three configurations for electrodes arrangement CW-MFC were used. In the first unit of CW-MFC, the anode was graphite plate (GPa) and cathode was also graphite plate (GPc), in the second CW-MFC unit, the anode was stainless st

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Improving the Performance of Constructed Wetland Microbial Fuel Cell (CW- MFC) for Wastewater Treatment and Electricity Generation
...Show More Authors

The current study deals with the performance of constructed wetland (CW) incorporating a microbial fuel cell (MFC) for wastewater treatment and electricity generation. The whole unit is referred to as CW-MFC. This technique involves two treatments; the first is an aerobic treatment which occurs in the upper layer of the system (cathode section) and the second is anaerobic biological treatment in the lower layer of the system (anode section). Two types of electrode material were tested; stainless steel and graphite. Three configurations for electrodes arrangement CW-MFC were used. In the first unit of CW-MFC, the anode was graphite plate (GPa) and cathode was also graphite plate (GPc), in the second CW-MFC unit, the anode was stainless steel

... Show More
Crossref (9)
Crossref