Preferred Language
Articles
/
1BjhfpUBVTCNdQwC8i4b
Assessment of the accuracy of a fifth generation apex locator (in vitro study)
...Show More Authors

Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for the purpose of orthodontic treatment and with fully-formed roots, were used in this study. Endodontic access cavity was prepared in each tooth and canal patency up to the apical foramen was checked with a #15 stainless steel K-file. No root canal preparation was performed. Root canal length measurement was done directly and electronically using two apex locators (Joypex 5 and Root ZX). Direct measurement of the root canal length was done by introducing a #15 K-file inside the root canal until its tip was just visible at the apical foramen, then removed from the root canal and its length was measured (in mm) and subtracted by 0.5 mm. For electronic measurement, the teeth were fixed in a sponge soaked in saline and the root canals were also filled with saline. The lip electrode was attached to the sponge and the apex locators were used according to the manufacturers' instructions. The file holder was clipped to the metal shaft of a #15 K-file and the file was then inserted inside the root canal and advanced until the display reading on the LCD of the apex locator was "0.5". The file was then removed from the root canal and its length was measured (in mm). The differences between the readings of each apex locator and the actual length of each canal were computed, and the results were analyzed statistically by paired t-test using SPSS Version 13. Results: The results of this study showed that the Joypex 5 apex locator showed a lower mean difference than the Root ZX apex locator as compared with the actual length, which was statistically significant (p<0.05). Concerning the accuracy of the two apex locators, Joypex 5 apex locator recorded the apical constriction exactly in 67%, while the Root ZX apex locator in only 25%. Within ±0.5 mm from the actual length, the accuracy of the Joypex 5 and the Root ZX were 83% and 67%, respectively. Within ±1 mm from the actual length, the accuracy of the Joypex 5 and the Root ZX were 100% and 96%, respectively. Conclusion: The Joypex 5 apex locator which is a fifth generation apex locator was more accurate in recording the apical constriction as compared with the Root ZX apex locator which is a third generation apex locator.

Preview PDF
Quick Preview PDF
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Radiological Assessment of Mandibular Retromolar Canal (MRMC) Using CBCT-Radiographs in a Sample of Iraqi Patients
...Show More Authors

Background: Because of its clinical and surgical importance and lack of precise information about this rare and important anatomical landmark, this study was designed to detect the presence, configurations and length of Mandibular Retromolar Canal (MRMC) with aid of CBCT visualization. Materials and methods: In this retrospective study the data was obtained from Specialist Health Center in AL-Sadder city in Baghdad for (100) patients with 200 inferior dental canal, all of them referred to CBCT scan (Kodak 9500, French origin). The scanning was done with tube voltage 90 kVp, tube current with 10mA and exposure time was 10 s., the field of view was measured with 5cm x 3.7cmwith 0.03mm voxel size Results: In the present study the prevalence of

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jul 07 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of mandibular radiomorphometric indices as predictors of osteoporosis in postmenopausal women (Cephalometric reconstructed computed tomographical study)
...Show More Authors

Background: Osteoporosis affects almost all of the bones in the female body; the most important one in the facial bone is mandible. Menopause is defined as an absence of the menses for one year. During this time, estrongen, progesterone and ovarian androgens production are diminished due to adult onset ovarian failure which leads to osteoporosis. This study aimed to evaluate the use of computed tomography mandibular morphometric indices for the assessment of pre and postmenopausal osteoporotic women. Subjects and material: This study conducted on 50 Iraqi females divided into 2 groups 20 -30years old as a control group and over50 years old as a study group attending Al-Karkh hospital, Department of Computed Tomography.(each group25 female).

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 23 2023
Journal Name
Cumhuriyet Dental Journal
The effectiveness of continuous versus sequential chelation in the removal of smear layer and their influence on push-out bond strength of Bio-C sealer (An in vitro study)
...Show More Authors

Objectives: Successful endodontic treatment outcome requires effective shaping and cleaning of root canals. This study aims to evaluate the smear layer removal after continuous chelation (CC) ) NaOCL\HEDP( and sequential chelation (SC) )NaOCL\EDTA( and their influence on the push-out bond strength (POBS) of Bio-C sealer. Materials and Methods: Palatal roots of the maxillary first molar (n=72) were divided into four groups (n=18) as follows: 3% NaOCL, SC: 3% NaOCL followed by 17% EDTA, CC: 3% NaOCL \9% HEDP and Distilled water. Thirty-two roots (n=8/group) were split longitudinally for smear layer evaluation using SEM. Forty roots were obturated with Guttapercha and Bio-C sealer using a single cone technique. Thre

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Tue Jan 07 2020
Journal Name
International Journal Of Research In Pharmaceutical Sciences
Fifth stage pharmacy students’ knowledge and perceptions about generic medicines
...Show More Authors

The aim of the current study was to evaluate the knowledge and perception of the fifth stage pharmacy students (college of pharmacy/ University of Baghdad /Iraq) regarding generic medicines. This study is a cross-sectional study carried in a college of pharmacy /University of Baghdad during the period from (November 2018- March 2019). The number of students included in the current study was 168 undergraduate stager pharmacists. A questionnaire was used to collect data of the study. Nearly 86% of the students said that they had heard of generic and brand medicines, and pharmacy was the main source of knowledge regarding generic medicines (66.7%).  About (33.3%) of the respondents agreed that generic medicines are bioequivalent to br

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Oct 17 2018
Journal Name
Iraqi Journal Of Laser
The Effect of using 940 nm Diode Laser in Comparison with Endoactivator on Radicular Dentin Permeability and Smear Layer Removal (An in Vitro Study)
...Show More Authors

Abstract: The aim of this study is to assess the effectiveness of 940 nm diode laser in comparison to Endoactivator in elimination of smear layer in terms of radicular dentin permeability and ultra-structural changes of root canal walls by SEM evaluation. Twenty-eight single-rooted extracted lower premolars were instrumented up to size X4 (protaper Next, Dentsaply) and divided into two experimental groups according to the irrigation system, G1; activated by EndoActivator and G2; activated by Diode laser 940 nm, CW mode, 1.7 W. Afterward, the roots were made externally impermeable, filled with 2%methylene blue dye, divided horizontally into three segments representing the apical, middle, and coronal thirds then examined under stereo- micr

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
COMPARISON OF THE PERFORMANCE OF THE FOREHANDKICK (STRAIGHT AND ACCOMPANIED BY FORWARD ROTATION) IN TERMS OF ACCURACY AND SPEED AMONG THE PLAYERS OF THE NATIONAL TEAM (ADVANCED CATEGORY) IN TENNIS
...Show More Authors

Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
COMPARISON OF THE PERFORMANCE OF THE FOREHANDKICK (STRAIGHT AND ACCOMPANIED BY FORWARD ROTATION) IN TERMS OF ACCURACY AND SPEED AMONG THE PLAYERS OF THE NATIONAL TEAM (ADVANCED CATEGORY) IN TENNIS
...Show More Authors

Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
COMPARISON OF THE PERFORMANCE OF THE FOREHANDKICK (STRAIGHT AND ACCOMPANIED BY FORWARD ROTATION) IN TERMS OF ACCURACY AND SPEED AMONG THE PLAYERS OF THE NATIONAL TEAM (ADVANCED CATEGORY) IN TENNIS
...Show More Authors

Publication Date
Fri Oct 02 2020
Journal Name
International Development Planning Review
COMPARISON OF THE PERFORMANCE OF THE FOREHANDKICK (STRAIGHT AND ACCOMPANIED BY FORWARD ROTATION) IN TERMS OF ACCURACY AND SPEED AMONG THE PLAYERS OF THE NATIONAL TEAM (ADVANCED CATEGORY) IN TENNIS
...Show More Authors

Publication Date
Mon Feb 13 2023
Journal Name
Journal Of Educational And Psychological Researches
Evaluation of English Language Textbooks for Fifth and Sixth Graders Based on the American Council Criteria for Teaching Foreign Languages (ACTFL)
...Show More Authors

Abstract

This study aims to identify the extent to which the criteria of the American Council for Teaching Foreign Languages (ACTFL) are included in the English language books for the fifth and sixth graders. To achieve the objective of the study, a content analysis card was prepared, where the classification of language proficiencies was divided into five main levels (beginner, intermediate, advanced, superior, and distinguished) of the four language skills (listening, speaking, reading, and writing), The content analysis card consisted of (89) indicators distributed at the four levels of language skills as follows: Listening (17), speaking (33), reading (15), and writing (26). The study sample consisted of Engl

... Show More
View Publication Preview PDF