To explore the potential for in vitro rapid regeneration of Spanish dagger (Yucca gloriosa 'Variegata'), different concentrations of 6-Benzyladenine (BA), 1-naphthaleneacetic acid (NAA) and combinations of both were evaluated for callus induction initiated on leaf and bud (terminal and axillary buds) explants using Murashige and Skoog (MS) medium. Callus response induction percentage, fresh weight, color and texture of the callus were assessed after 1.5 and 6.0 months in culture. The appropriate medium for callus initiation on leaf explants was MS medium supplemented with 6.0 mg/L NAA. A combination of 0.2 mg/L BA and 1.5 mg/L NAA also exhibited a remarkable callus induction on bud explants. Effect of thidiazuron (TDZ) addition to the culture medium supplemented with BA and NAA at various concentrations (0.0, 0.1, 0.5 or 1.0 mg/L) was investigated. Faster callus growth and more callus proliferationon from bud explants were observed in MS medium supplemented with 0.1 mg/L BA + 1.5 mg/L NAA + 1 mg/L TDZ. Results showed that TDZ was more effective on callus induction than BA or NAA, however some combinations gave direct shoot regeneration. Calli derived from bud explants were whitish to creamy and compact, while calli derived from leaf explants were greenish.
A field experiment was conducted during winter season of 2021 at a research station of college of agricultural engineering sciences, university of Baghdad to determine the response of active fertility percentage and seed yield and its components of faba bean (Vicia faba L. cv. Aguadulce) to distance between plants and spraying of nano and traditional boron. A Randomized Complete Block Design according to split-plots arrangement was used at three replicates. The main plots were three distances between plants (25, 35 and 45 cm), while the sub plots including spraying of distilled water only (control treatment), spraying of boron at a 100 mg L-1 and spraying of nano boron at two concentrations (1
... Show MoreThis paper investigates the experimental response of composite reinforced concrete with GFRP and steel I-sections under limited cycles of repeated load. The practical work included testing four beams. A reference beam, two composite beams with pultruded GFRP I-sections, and a composite beam with a steel I-beam were subjected to repeated loading. The repeated loading test started by loading gradually up to a maximum of 75% of the ultimate static failure load for five loading and unloading cycles. After that, the specimens were reloaded gradually until failure. All test specimens were tested under a three-point load. Experimental results showed that the ductility index increased for the composite beams relative to the reference specim
... Show MoreThe current research aims to describe the level of responsiveness and awareness of the officials of the General Company for Construction Industries to the indicators of the blue market strategy of (1. reduction 2. exclusion 3. increase 4. innovation) and the degree of prioritization according to their importance as well as the differences in the responses of the sample investigated according to the personal variables. As a main tool in the collection of data from the sample, which consisted of(34) officers (Associate, Manager, Section Manager, Division Officer) in the company being investigated, and computed mean, standard deviations, percentage weights,and test (x2 ) based on the SPSS. The research reached the following
... Show MoreThis paper investigates the experimental response of composite reinforced concrete with GFRP and steel I-sections under limited cycles of repeated load. The practical work included testing four beams. A reference beam, two composite beams with pultruded GFRP I-sections, and a composite beam with a steel I-beam were subjected to repeated loading. The repeated loading test started by loading gradually up to a maximum of 75% of the ultimate static failure load for five loading and unloading cycles. After that, the specimens were reloaded gradually until failure. All test specimens were tested under a three-point load. Experimental results showed that the ductility index increased for the composite beams relative to the refe
... Show More