Preferred Language
Articles
/
0xfBPpMBVTCNdQwC4886
Iatrogenic atrial septal defect post radiofrequency ablation in patients with left atrial SVT: Predictors and outcomes
...Show More Authors

atrogenic atrial septal defect (IASD), post Catheter ablation during electrophysiological study simply can be assess with Echocardiography nowadays ablation consider the main line in the managements of patients with various type of arrhythmia. This study aims to de-termine the outcomes of Iatrogenic Atrial Septal Defect (IASD) six months post radiofrequency ablation (RF) procedure of left atrial arrhythmia using non-invasive Transtho-racic Echocardiography (TTE) parameters (LVEF, E/e` and ASD size) with sheath size as predictors of atrial septal defect closure. Patients and methods: A prospective study was con-ducted in Iraqi Centre for Heart Diseases included 47 patients post Electrophysiology procedure and ablation of left atrial SVT were selected after non complicated tran-septal puncture using two size of sheath in three type of arrythmia and follow up done simply with Transthoracic echocardiography (TTE) was used to evaluate the atrial septal defect (ASD) (from May 2019-May 2020) in Iraqi centre for heart diseases. Results: After Electrophysiology study, results of this study were analysed and collected according to duration of procedure, sheath size and number that used in sep-tostomy, size of IASD and Echocardiographic parameters. The mean age of the patients (36.28±10.34 years), males were 23 (48.9%) while females were 24 (51.1%), without structural heart diseases and good LV function with mean EF (64.68± 5.23%). Iatrogenic atrial septal defects (IAS-Ds)were detected by TTE in all patients with range from (2-5) mm with mean of (3.47±0.92), performed by Trans-septal puncture (TSP), either with single 8 French sheath in 24 (51.06%) patients or single 12 French sheath in 17 (36.17%) patients while 6 (12.77%) patients the defect was performed by double transseptal sheath. spontane-ous closure occur in 35(74%) patients within first three months with clear significant association between size of ASD that related to the sheath size and duration of procedure (P<0.0001). We notice that some Echocardiographic parameters were also associated with IASD without any clinical complications and/ or deterioration. Conclusions: post catheter ablation number and size of sheath and duration of ablation consider as a predictor to closure of residual atrial septal defect post atrial sep-tostomy and can simply assess with non-invasive Trans-thoracic Echocardiography parameters such (Atrial septal defect size and body surface area) during initial six months follow up. © 2021, Venezuelan Society of Pharmacology and Clinical and Therapeutic Pharmacology. All rights reserved.

Scopus
Publication Date
Thu May 31 2018
Journal Name
International Journal Of Control And Automation
Power Flow Control of Iraqi International Super Grid with Two-Terminal HVDC Techniques Using PSS/E
...Show More Authors

View Publication
Crossref (5)
Crossref
Publication Date
Wed Apr 01 2015
Journal Name
Journal Of Environmental Engineering
Using Granular Dead Anaerobic Sludge as Permeable Reactive Barrier for Remediation of Groundwater Contaminated with Phenol
...Show More Authors

Scopus (21)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Fri Dec 22 2023
Journal Name
Eastern-european Journal Of Enterprise Technologies
Evaluating the impact of structure parameters on the acoustic performance of an exhaust muffler with shells
...Show More Authors

Recently, environmental noise has arisen from various sources, such as those from exhaust mufflers of combustion engines found in cars, trucks, or power generators, which produce significant noise during their operation. Controlling the radiated noise from these mufflers is a major factor in improving acoustic comfort and minimizing the impact on the surrounding communities. Numerous research has been presented for this reason by modification of the internal structure of the exhaust muffler. The main objective of this work is to reduce the noise level emitted from exhaust mufflers. This can be achieved by adjusting structure parameters to attenuate the surrounding environment's radiated noise. Analysis of pressure-wave propagation h

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Tue Aug 03 2021
Journal Name
Key Engineering Materials
A Comparison Study between Asymmetrical Castellated Steel Beams Encased by Reactive Powder Concrete with Laced Reinforcement
...Show More Authors

The main objectives of this study are to study the enhancement of the load-carrying capacity of Asymmetrical castellated beams with encasement the beams by Reactive Powder Concrete (RPC) and lacing reinforcement, the effect of the gap between top and bottom parts of Asymmetrical castellated steel beam at web post, and serviceability of the confined Asymmetrical castellated steel. This study presents two concentrated loads test results for four specimens Asymmetrical castellated beams section encasement by Reactive powder concrete (RPC) with laced reinforcement. The encasement of the Asymmetrical castellated steel beam consists of, flanges unstiffened element height was filled with RPC for each side and laced reinforced which are use

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
A comparison among Different Methods for Estimating Regression Parameters with Autocorrelation Problem under Exponentially Distributed Error
...Show More Authors

Multiple linear regressions are concerned with studying and analyzing the relationship between the dependent variable and a set of explanatory variables. From this relationship the values of variables are predicted. In this paper the multiple linear regression model and three covariates were studied in the presence of the problem of auto-correlation of errors when the random error distributed the distribution of exponential. Three methods were compared (general least squares, M robust, and Laplace robust method). We have employed the simulation studies and calculated the statistical standard mean squares error with sample sizes (15, 30, 60, 100). Further we applied the best method on the real experiment data representing the varieties of

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Free Vibration Analysis of Laminated Composite Plates with General Boundary Elastic Supports Under Initial Thermal Load
...Show More Authors

Free vibration behavior was developed under the ratio of critical buckling temperature of laminated composite thin plates with the general elastic boundary condition. The equations of motion were found based on classical laminated plate theory (CLPT) while the solution functions consists of trigonometric function and a continuous function that is added to guarantee the sufficient smoother of the so-named remaining displacement function at the boundaries, in this research, a modified Fourier series were used, a generalized procedure solution was developed using Ritz method combined with the imaginary spring technique. The influences of many design parameters such as angles of layers, aspect ratio, thickness ratio, and ratio of initial in-

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Feb 15 2025
Journal Name
Iraqi Journal Of Science
Effect of Aluminum Dust Particles on Plasma Parameters at Different Gas Pressure with Different Dust Contents
...Show More Authors

In this work, the effect of aluminum (Al) dust particles on the DC discharge plasma properties in argon was investigated. A magnetron is placed behind the cathode at different pressures and with varying amounts of Al. The plasma temperature (Te) and density (ne) were calculated using the Boltzmann equation and Stark broadening phenomena, which are considered the most important plasma variables through which the other plasma parameters were calculated. The measurements showed that the emission intensity decreases with increasing pressure from 0.06 to 0.4 Torr, and it slightly decreases with the addition of the NPs. The calculations showed that the ne increased and Te decreased with pressure. Both Te and ne were reduced by increasing

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Recovery of methyl orange from aqueous solutions by bulk liquid membrane process facilitated with anionic carrier
...Show More Authors

Dyes are extensively water-soluble and toxic chemicals. The disposing of wastewater rich with such chemicals has severely impacted surface water quality (rivers and lakes). In the current study, an anionic dye, methyl orange, were extracted from wastewater fluids using bulk liquid membranes supplemented with an anionic carrier (Aliquat 336 (QCI)). Parameters including solvent type (carbon tetrachloride and chloroform), membrane stirring speed (100-250 rpm), mixing speed of both phases (50-100 rpm), The feed pH (2-12) and implemented temperature (35-60 °C) were thoroughly analyzed to determine the effect of such variables on extraction effectiveness. Furthermore, the effect of methyl orange (10-50 ppm) in the feed stage and NaOH (0

... Show More
View Publication
Scopus (8)
Crossref (1)
Scopus Crossref
Publication Date
Wed Apr 30 2025
Journal Name
Iraqi Journal Of Science
The Influence of Fear on the Dynamics of Harvested Prey-Predator Model with Intra-Specific Competition
...Show More Authors

The influence of fear on the dynamics of harvested prey-predator model with intra-specific competition is suggested and studied, where the fear effect from the predation causes decreases of growth rate of prey.  We suppose that the predator attacks the prey under the Holling type IV functional response. he existence of the solution is investigated and the bounded-ness of the solution is studied too. In addition, the dynamical behavior of the system is established locally and globally. Furthermore, the persistence conditions are investigated. Finally, numerical analysis of the system is carried out.

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Fri Jan 01 2016
Journal Name
8th Conference On Power Electronics, Machines And Drives (pemd), Glasgow, Uk
Design of tubular moving magnet linear alternator for use with an external combustion - free piston engine
...Show More Authors

Scopus (15)
Crossref (13)