Preferred Language
Articles
/
0RbX3osBVTCNdQwCkuIQ
RAPID DETERMINATION OF SPHINGANINE AND SPHINGOSINE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USING MONOLITHIC COLUMN
...Show More Authors

A rapid high performance liquid chromatography method for the determination of sphinganine (Sa) and sphingosine (So) in urine samples by employing a silica-based monolithic column is described. The samples were first extracted using ethyl acetate and derivatized using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol. C20 sphinganine was used as internal standard. Under the optimized conditions, separation was achieved using a mixture of methanol:water (93:7, v/v), column temperature at 30°C, flow rate of 1 mL min−1, and an injection volume of 10 μL. Good linearity was obtained for Sa and So over the concentration range 20–500 ng mL−1(correlation coefficients ≥0.9978). The detection limits were 0.45 ng mL−1 for Sa and 1.60 n g mL−1 for So in male urine; in female urine the values were 0.85 ng mL−1 and 2.62 ng mL−1 for Sa and So, respectively. Recoveries for spiked urine samples ranged from 98.6 to 108.2% for Sa and 99.9 to 104.0% for So. A marked reduction in separation time (less than 6 min) was found compared to approximately 14 min by using a conventional C18 particle column. Twenty-two urine samples from the healthy donors and seven samples from the liver cancer patients were analyzed using the method.

Scopus Clarivate Crossref
View Publication
Publication Date
Wed Jan 01 2003
Journal Name
Turkish Journal Of Chemistry
Gas Chr Gas Chromatographic Separ aphic Separation of Phenol Deriv ation of Phenol Derivatives by Schiff- y SchiffBase Liquid Crystalline Stationary Phases
...Show More Authors

The chromatographic behaviour of liquid crystalline compounds benzylidene-p-aminobenzoic acid and 4-(p-methyl benzylidene)-p-aminobenzoic acid as stationary phases for the separation of dimethylphenol isomers was investigated. These isomers were analysed on benzylidene-p-aminobenzoic acid within a nematic range of 169-194 ◦C with a temperature interval of 5 ◦C. Better peak resolution was at a column temperature of 190 ◦C. The analysis was repeated on a 4-(p-methyl benzylidene)-p-aminobenzoic acid column at a nematic temperature of 256 ◦C, which represented the end of the nematic range, and gave the optimum peak resolution. It was found that isomer better separation was obtained at 20% loading for both liquid crystal materials. Other

... Show More
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Lab-On-a-Chip an integrated microfluidic device sensitive low-Cost, and Rapid with a syringe pump for Analysis of Ibuprofen
...Show More Authors

Abstract: Microfluidic devices present unique advantages for the development of efficient drug assay and screening. The microfluidic platforms might offer a more rapid and cost-effective alternative. Fluids are confined in devices that have a significant dimension on the micrometer scale. Due to this extreme confinement, the volumes used for drug assays are tiny (milliliters to femtoliters).

 In this research, a microfluidic chip consists of micro-channels carved on substrate materials built by using Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters have influence on the width, depth, roughness of the chip. In order to have regular

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 01 2014
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Strategic Performance Evaluation Using Benchmarking Technique: Applied Research In The Sample Of Offices Of Inspectors General
...Show More Authors

In light of the rapid changes in the business environment and the entry of administrative leaders in the challenges of the atheist and twenty- increasing competition between sectors and the desire to acquire the skills, the traditional methods are no longer viable, which requires doing evaluates performance according to a more holistic, rather than limiting the performance evaluation on the financial hub that has not longer enough alone, as well as benchmarking method that has proven successful in developed countries as a way to develop and improve products and services.

I've touched your search to the development of indicators evaluating the performance and preparation of a mechanism for making comparisons of reference between o

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Spectrophotmetric Micro determination of promrthazine hydrochloride in pharmaceutical
...Show More Authors

a simple accurate and sensitive spectrophotometric method for the determination of promethazine HCI has been developed the method is based on the oxidative coupling reaction of promethazine

View Publication Preview PDF
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Iraqi Journal Of Physics
Use of zeolite to reduce the radioactivity of cesium -137 in the liquid waste
...Show More Authors

 Prepared zeolite type A was used for theremoval of cesium ions from aqueous solution. The experimental data were analyzed by Langmuir, Freundlich isotherms. Various parameters, such as contact time, zeolite weight, pH, and initial concentration, were studied. The results indicated that the highest removal efficiency was95.53% at (2h time, 0.04 g weight, and pH=6.8). The results also showed that the Freundlic model fits well with the experimental results and is better than the Langmuir model.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Environmental Engineering
Influence of Clay Lens on Migration of Light Nonaqueous Phase Liquid in Unsaturated Zone
...Show More Authors

Scopus (8)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Tue Aug 02 2022
Journal Name
Karbala International Journal Of Modern Science
Performance Simulation for Adaptive Optics Technique Using OOMAO Toolbox
...Show More Authors

The Adaptive Optics technique has been developed to obtain the correction of atmospheric seeing. The purpose of this study is to use the MATLAB program to investigate the performance of an AO system with the most recent AO simulation tools, Objected-Oriented Matlab Adaptive Optics (OOMAO). This was achieved by studying the variables that impact image quality correction, such as observation wavelength bands, atmospheric parameters, telescope parameters, deformable mirror parameters, wavefront sensor parameters, and noise parameters. The results presented a detailed analysis of the factors that influence the image correction process as well as the impact of the AO components on that process

View Publication
Scopus (6)
Crossref (1)
Scopus Crossref
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Engineering
Numerical and experimental investigation on the performance of the capillary tube using R-134a and R-600a
...Show More Authors

In this paper, isobutane (R-600a) is used as a suitable substitute for (R-134a) when changing the length of capillary tube. And the experimental data on capillary tube are obtained under different conditions such as (subcooling and ambient temperatures) on domestic refrigerator (9ft3 size), this data shows that (R-600a) a suitable substitute for (R134a) .The test presented a model for a steady state, two-phase flow in capillary tube for vapour compression system .The numerical model depends on conservation equations (mass, energy and momentum) as wall as the equation of state for refrigerant. The solution methodology was implemented by using finite difference techniques. The system results indicate that it is possible to change the refri

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Dec 03 2017
Journal Name
Baghdad Science Journal
Determination of the Level of some Adipokines in Hypo-and Hyperthyroids Patients in Baghdad City
...Show More Authors

Determination of the level of adipokines (obestatin, vaspin, tumor necrosis factor-? and interleukin-6)in hypo-and hyperthyroid patients from Educational Baghdad Hospital in Baghdad City was investigated. Fifty patients with hypothyroidism and Fifty patients with hyperthyroidism were selected. A control group of thirty euthyroid persons was included. Blood was collected by vein puncture and serum was separated and stored at –20C. Adipokines (obestatin, vaspin, tumor necrosis factor-? and interleukin-6) were estimated using ELISA method. The findings show a significant (p<0.05) increase in obestatin level in hypothyroid patients, while there is no significant difference in hyperthyroid patientsas compared with the euthyroid subjects.

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Journal Of Physics: Conference Series
Determination of some biochemical parameters in sera of normotensive and hypertensive obese female in Baghdad
...Show More Authors
Abstract<p>Obesity is a disease describe a case of excessive accumulation of body fats. Obesity is linked to the morbidity of human health, such as the development of hypertension. The study designed to investigate the levels of glucose, urea, creatinine, and lipid profile parameters in sera of obese female and hypertensive obese female. The study included 90 subjects who divided onto three groups equally, in which they are healthy control, normotensive obese, and hypertensive obese. A significant elevation (P<0.01) has observed in the level of glucose, urea, creatinine, triglycerides (TGs), cholesterol, LDL-C, and VLDL-C in obese females compared with control, yet only TGs and VLDL-C were si</p> ... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Crossref