Preferred Language
Articles
/
0Ia7soYBIXToZYALSLGS
Impact Induced Responses of Saturated and Dry Dense Sand
...Show More Authors

The present article includes an experimental study of the behavior of dry and saturated dense sandy soil under the action of a single impulsive load. Dry and saturated dense sand models were tested under impact loads. Different falling masses from different heights were conducted using the falling weight deflectometer (FWD) to provide the single pulse energy. The responses of dense soils were evaluated at surface of soil under impact load. These responses include; displacements, velocities, and accelerations that are developed due to the impact acting at top and the displacement at different depths within the soil using the falling weight deflectometer (FWD) and accelerometers (ARH-500A waterproof, and low capacity acceleration transducer) that are embedded in the soil in addition to soil pressure gauges and then recorded using the multi-recorder TMR-200. Based on the experimental test results, it was found that as the sand becomes saturated, the amplitude of the force-time history decreases by about 10-22% since the voids are filled with water which lead to less contact points between particles. Moreover, the resulting vertical displacement due to impact increases by about 20-60% as compared to the case of dry sand at a depth B (where B is the diameter of the bearing plate) from the bearing plate. Such a behavior is related to two compressive waves through the saturated medium; the fluid wave and the soil skeleton wave with a coupled motion of those two waves hence, makes the displacement to be larger in the saturated soil. The horizontal displacement within the soil medium at a distance B away from the edge of the footing are less than the displacements in dry state. The excess pore water pressure increases by about 40% as the amplitude of the impact force increases due to the increase of the contact pressure.

Scopus Clarivate Crossref
Publication Date
Fri Dec 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Color stability of nano resin-modified glass Ionomer restorative cement after acidic and basic medications challenge
...Show More Authors

Background: Color stability of glass ionomers (GIs) could be affected by many factors such as pH and consumption of liquid medications like antibiotics. Most common antibiotics used during childhood are amoxicillin suspension (AM.S) and azithromycin suspension (AZ.S) which have acidic and basic pH respectively. Aim: to evaluate and compare the effect of AM.S and AZ.S on color stability of nano resin-modified GI. Methods: Thirty disc of nano resin-modified glass ionomer (2mm height x 4mm diameter) were divided into three groups (n=10 for each) and independently exposed to AM.S, AZ.S, and artificial saliva (A.S.). Color stability was evaluated in triplicate by VITA Easyshade® before and after three immersion protocols, repeated over a thr

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Theoretical Discussion of Electron Transport Rate Constant at TCNQ / Ge and TiO<sub>2</sub> System
...Show More Authors

View Publication
Scopus (12)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sat Jan 20 2024
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Adhesion, roughness, wettability, and dielectric strength of elastomers liquid blends for high-density fiberboard wood adhesive
...Show More Authors

In the present study, the physical characteristics of elastomer (EL) blend with natural polymers such as polyvinyl alcohol (PVA), Dexrin (D), Arabic gum (AG), and corn starch (CS) based on high-density fiberboard wood adhesives were investigated. The EL blends were prepared by dissolving AG, D, PVA, and CS in deionized water at 70 °C for 1 h under magnetic stirring continuously until the solution was clear, and blends were made with a weight of 60/40 (w/w); then were cast into a mold with a 20 cm diameter and left at room temperature for 24 h to ensure complete water removal and drying of the samples. The prepared EL and EL blend structures, adhesion strengths, roughness, wettings, and dielectric strengths, were investigated. The modifi

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Sat Jan 20 2024
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Assessment of Monocyte Chemoattractant Protein -1 and Fertility Hormones in Iraqi Women with Polycystic Ovarian Syndrome
...Show More Authors

Polycystic ovarian syndrome (PCOS) is a well-known endocrinopathy and one of the most frequent endocrine-reproductive-metabolic syndromes in women, which can result in reduced fertility. While the actual cause is unknown, PCOS is regarded as a complicated genetic characteristic with a great degree of variability. Moreover, hormones and immune cells, including both innate and acquired immune cells, are thought to interact in PCOS. Chronic low-grade inflammation raises the risk of autoimmune disease. The study's purpose is to investigate the chemokine monocyte chemoattractant protein-1 (MCP-1) and fertility hormones in samples of women patients with polycystic ovary syndrome (PCOS) in the City of Medicine. Sixty PCOS women comprise 30 heal

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Fri Feb 03 2023
Journal Name
Nano Hybrids And Composites
Synthesis and Characterization of Nanoparticles Extracted from &lt;i&gt;Catharanthus roseus&lt;/i&gt; Plant
...Show More Authors

The Catharanthus roseus plant was extracted and converted to nanoparticles in this work. The Soxhlet method extracted alkaloid compounds from the plant Catharanthus roseus and converted them to the nanoscale. Chitosan polymer was used as a linking material and converted to Chitosan nanoparticles using Sodium TriPolyPhosphate (STPP). The extracted alkaloids were linked with Chitosan nanoparticles CSNPs by maleic anhydride to get the final product (CSNPs- Linker- alkaloids). The synthesized (CSNPs- Linker- alkaloids) was characterized using SEM spectroscopy UV–Vis., Zeta Potential, and HPLC High-Performance Liquid Chromatography. Scanning electron microscope (SEM) analysis shows that the Chitosan nanoparticles (CSNPs) have small dim

... Show More
View Publication
Crossref (3)
Clarivate Crossref
Publication Date
Sun Mar 26 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Evaluation of Poisoning Cases in the Poisoning Consultation Center and Forensic Medicine Institute within Baghdad area
...Show More Authors

Social factors may affect the available sources of toxic substances and causes of poisoning, and these factors may change over time. Additionally, understanding the characteristics of poisoning cases is important for treating such patients. Therefore, the present study investigated the characteristics of poisoning cases in Baghdad Poisoning Consultation Center (PCC) and Forensic Medicine Institute (FMI). Data on all poisoning cases reported in PCC and FMI during 2013 were retrospectively obtained from medical records. Total of 1131 reports of poisoning cases (1082 from PCC and 49 from FMI) were analyzed according to age, sex, geographical distribution and causes of poisoning according to the type and class of poisoning agent. The results

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Mar 01 2018
Journal Name
Case Studies In Thermal Engineering
The temperatures distributions of a single-disc clutches using heat partitioning and total heat generated approaches
...Show More Authors

View Publication
Scopus (36)
Crossref (33)
Scopus Clarivate Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Effect of plasma jet on the water and hydrogen peroxide that used for assisted teeth bleaching
...Show More Authors

In this work the interaction of plasma jet with water and hydrogen peroxide liquids used for assisted teeth bleaching by plasma jet had been study. A homemade plasma jet system was used. The plasma jet supply by 15 W electrical power generated by high voltage power supply of 9.6 kV peak to peak and frequency of 33 kHz .this power supply generate high electric field on electrodes that would be enough to ionize the argon gas. Some important agents were study such as the effect of the Ar gas flow rates on the length of the plasma jet, the influence of plasma jet on some properties of water and two hydrogen peroxide concentrations 25 % and 30 % like pH, conductivity and liquid temperature for different exposure time. The liquids temperature

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Colorimetric Determination of Salbutamol Sulfate using Spectrophotometry-Continuous Flow Injection Technique in Pure and Pharmaceutical Forms
...Show More Authors

Simple, precise and economic batch and flow injection analysis (FIA)-spectrophotometric methods have been established for simultaneous determination of salbutamol sulfate (SLB) in bulk powder and pharmaceutical forms. Both methods based on diazotization coupling reaction of SLB with another drug compound (sulfadimidine) as a safe and green diazotization agent in alkaline medium. At 444 nm, the maximum absorption of the orange azo-dye product was observed. A thorough investigation of all chemical and physical factors was conducted for batch and FIA procedures to achieve high sensitivity. Under the optimized experimental variables, SLB obeys Beer’s law in the concentration range of 0.25-4 and 10-100 μg/mL with limits of detection of 0.0

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (4)
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Iraqi Journal Of Hematology
Evaluation of angiopoietin-2 level in patients with multiple myeloma at presentation and in remission state
...Show More Authors

The study aimed to assess the level of ANG‑2 in MM patients at diagnosis and in remission state and elaborate on its correlation with interleukin‑6 (IL‑6) and beta‑2 microglobulin (B2M) levels. Sixty MM patients; 20 newly diagnosed (ND), and 40 patients in remission were included. Twenty healthy individuals were included as a control group. Plasma levels of ANG‑2, B2M, and IL‑6 were tested by enzyme‑lin ked immunosorbent assay. There are significant statistical differences between ND patients and those in remission in hemoglobin, neutrophil count, blood urea, serum creatinine, glomerular filtration rate, B2M, IL6, and ANG‑2 (P = 0.001, 0.033, 0.005, 0.001, 0.001, 0.001, 0.004, and 0.001, respectively). ANG‑2 showed signifi

... Show More
View Publication
Crossref (1)
Clarivate Crossref