Preferred Language
Articles
/
0BeMX5MBVTCNdQwCfNJi
A hand-held hybrid gamma-near-infrared fluorescence imaging camera

Objectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamma small field of view camera, capable of displaying co-aligned images from both modalities, which can be fused into one image or viewed separately. This study is a preliminary investigation of the performance of the fluorescence component of this camera, including phantom studies and first images from a preclinical pilot study. Methods: The hybrid camera consists of a 1500 µm thick thallium doped caesium iodide columnar (CsI:Tl) scintillator coupled to an electron multiplying charged coupled device (EMCCD). A 1.0mm diameter tungsten pinhole collimator gives a 40mm x 40mm nominal field of view for an 8mm x 8mm CCD detection area. A fluorescence camera was aligned to provide the same field of view as the gamma camera with an LED ring as the excitation source. The performance of the fluorescence imaging was quantified in this study for the fluorophores ICG and IRDye800CW (CW800) using a range of bespoke phantom experiments. In vivo images were also obtained from a preclinical study of a targeted hybrid tracer (cRGD-CW800-TCO + TCO-DOTA-111In) in mice with HT29 colorectal cancer xenografts. RESULTS AND CONCLUSION: The portable hybrid camera prototype has been shown to successfully image dual NIR-gamma tracers using both in vitro and in vivo experimental models. With further development, this camera could be used intraoperatively, offering the benefits of gamma imaging at depth in tissues and high resolution surface NIR fluorescence imaging in a single imaging system.

Publication Date
Mon May 15 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Using Web Camera Enet to Measure Statistical Characteristic of Homogenous Target Illuminated by Different Tungsten Light

The effect of White Place Image ( Test Image )  A4   has been studied as a function of luminous intensity using the  t tu un ng gs st te en n    l la am mpp and web camera enet. It was found that the tungsten lamp gives almost even intensities for the three color band and  lighting composite at low voltage .while at high voltage causes a fare from each other .  The statistical characteristic(mean and stander deviation ) results for three colors composites RGB and lighting  composites L showed that the mean and stander deviation increases with the increase of voltage possibly owing to the increase image  resolution, which reflects the value of  stander deviation for the blue band

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 11 2018
Journal Name
Baghdad Science Journal
Thermoluminescence dosimetry of mixed neutron – gamma fields

The method of measurement dosimetry in neutron – gamma field by using CaSo4 : Dy (PTFE) disc which has a diameter of 1.3mm and thickness of 0.2mm and using hydrogenated material as a converters of neutron to recoil protons (n-p) reaction, the discs were irradiated by neutron source (241Am-Be) with flux of 4.5?105 n/cm2s for different time to obtain different dose. The TL signals, which we have been obtained by using the converters, are increases to 71%. So we can resolve the neutron and gamma in mixed field.

Crossref
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Italian Journal Of Pure And Applied Mathematics
Banach gamma-algebra modules and full stability

In this paper the full stable Banach gamma-algebra modules, fully stable Banach gamma-algebra modules relative to ideal are introduced. Some properties and characterizations of these classes of full stability are studied.

Scopus
View Publication
Publication Date
Tue Dec 22 2020
Journal Name
Collaboration And Integration In Construction, Engineering, Management And Technology
A Hybrid Conceptual Model for BIM Adoption in Facilities Management: A Descriptive Analysis for the Collected Data

Scopus (2)
Scopus Crossref
View Publication
Publication Date
Thu Jun 30 2022
Journal Name
Ipri Journal
Hybrid regimes: An Overview

Crossref (1)
Clarivate Crossref
View Publication Preview PDF
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Computational And Theoretical Nanoscience
Development of Wireless Controlling and Monitoring System for Robotic Hand Using Zigbee Protocol

Nowadays, the robotic arm is fast becoming the most popular robotic form used in the industry among others. Therefore, the issues regarding remote monitoring and controlling system are very important, which measures different environmental parameters at a distance away from the room and sets various condition for a desired environment through a wireless communication system operated from a central room. Thus, it is crucial to create a programming system which can control the movement of each part of the industrial robot in order to ensure it functions properly. EDARM ED-7100 is one of the simplest models of the robotic arm, which has a manual controller to control the movement of the robotic arm. In order to improve this control s

... Show More
Scopus (5)
Crossref (4)
Scopus Crossref
View Publication
Publication Date
Sun Oct 01 2023
Journal Name
Baghdad Science Journal
Using VGG Models with Intermediate Layer Feature Maps for Static Hand Gesture Recognition

A hand gesture recognition system provides a robust and innovative solution to nonverbal communication through human–computer interaction. Deep learning models have excellent potential for usage in recognition applications. To overcome related issues, most previous studies have proposed new model architectures or have fine-tuned pre-trained models. Furthermore, these studies relied on one standard dataset for both training and testing. Thus, the accuracy of these studies is reasonable. Unlike these works, the current study investigates two deep learning models with intermediate layers to recognize static hand gesture images. Both models were tested on different datasets, adjusted to suit the dataset, and then trained under different m

... Show More
Scopus (4)
Crossref (3)
Scopus Crossref
View Publication Preview PDF
Publication Date
Mon Oct 01 2007
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Flexor tend on injury of hand at zone II Early or delayed suture ?

Background: The healing of a sutured tendon in the hand usually occur with an unwanted amount of scarring that defeat good results. Many variables has been studied over many decades; timing of repair M’as a matter of debate. Zone II is the area where those variables mostly affect the results of treatment.
Objective: To study and evaluate the results of early or delayed repair under the effects of our local variables.
Method: Prospective study of 85 patients, which had flexor tendon repair at zone II by primary repair, delayed primary repair and tendon graft.
Results: Results showed a primary repair ended with better functional results than those with delayed repair and than those with tendon graft. Excellent & good results

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sun Apr 04 2010
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Comparative study between stapled versus hand sewn method for large bowel anastomosis surgery.

Background: intestinal anastomosis is one of the most commonly performed procedures it required to reestablish gastrointestinal continuity after surgical resection, traumatic disruption or bypass procedures. In last decade, advances in intestinal stapling devices have led to an increased frequency of stapled anastomosis. There are varieties of proposed benefit from a stapled technique: better blood supply, reduced tissue manipulation, less edema, uniformity of suture, adequate or perhaps wider lumen at the site of anastomosis, ease and rapidity.
Patient and methods: a prospective study was conducted on 103 patients who suffered from benign and malignant diseases in addition to trauma patients. They were d

... Show More
Crossref
View Publication Preview PDF
Publication Date
Wed May 01 2013
Journal Name
Ieee Journal Of Biomedical And Health Informatics
Classification of Finger Movements for the Dexterous Hand Prosthesis Control With Surface Electromyography

Scopus (286)
Crossref (262)
Scopus Clarivate Crossref
View Publication